Literature DB >> 3233886

Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography.

J R Jago1, A Murray.   

Abstract

Peripheral pulses have been recorded and analysed to determine the accuracy with which pulse transit times (PTTs) can be measured. Measurements of PTT between the ECG Q-wave and various peripheral sites were made in 10 normal subjects on 10 separate days. Mean values were determined for the ears (174 ms), fingers (245 ms), and toes (361 ms). The technique was sufficiently accurate to detect small changes in PTT due to changes in posture; sitting to lying, 5.2 ms. When comparing simultaneous measurements on bilateral sites only small differences in PTT were discovered, and these were not significant in the study group as a whole. However, these differences were significant in some individuals. When the subjects raised a single arm or leg, significant differences (38 ms and 49 ms respectively) were recorded between sides. The day-to-day repeatability sigma (expressed as the square root of the within-subject mean square variance) of individual PTT measurements on a subject (supine) was for ears, fingers and toes respectively 9.4, 9.2 and 12 ms. For right-left differences the repeatability was 7.2, 5.9 and 14 ms. Hence changes in PTTs, or differences between right and left sides, can be detected from single measurements with 95% confidence if they exceed approximately 20 ms in ears or fingers and 30 ms in toes.

Mesh:

Year:  1988        PMID: 3233886     DOI: 10.1088/0143-0815/9/4/003

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  11 in total

1.  Non-constrained blood pressure monitoring using ECG and PPG for personal healthcare.

Authors:  Youngzoon Yoon; Jung H Cho; Gilwon Yoon
Journal:  J Med Syst       Date:  2009-08       Impact factor: 4.460

2.  Accurate measurement of the pulse wave delay with imaging photoplethysmography.

Authors:  Alexei A Kamshilin; Igor S Sidorov; Laura Babayan; Maxim A Volynsky; Rashid Giniatullin; Oleg V Mamontov
Journal:  Biomed Opt Express       Date:  2016-11-16       Impact factor: 3.732

Review 3.  Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Authors:  Jochanan E Naschitz; Stanislas Bezobchuk; Renata Mussafia-Priselac; Scott Sundick; Daniel Dreyfuss; Igal Khorshidi; Argyro Karidis; Hagit Manor; Mihael Nagar; Elisabeth Rubin Peck; Shannon Peck; Shimon Storch; Itzhak Rosner; Luis Gaitini
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

4.  Impedance plethysmography for the evaluation of pulse-wave velocity in limbs.

Authors:  F Risacher; J Jossinet; E T McAdams; J McLaughlin; Y Mann; M Schmitt; A Matias; R Jarry
Journal:  Med Biol Eng Comput       Date:  1993-05       Impact factor: 2.602

5.  Adaptive network-based fuzzy inference system for assessment of lower limb peripheral vascular occlusive disease.

Authors:  Yi-Chun Du; Chia-Hung Lin
Journal:  J Med Syst       Date:  2010-04-13       Impact factor: 4.460

6.  Increase in pulse transit time to the foot after epidural anaesthesia treatment.

Authors:  A Babchenko; E Davidson; D Adler; Y Ginosar; V Kurz; M Nitzan
Journal:  Med Biol Eng Comput       Date:  2000-11       Impact factor: 2.602

7.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

8.  Pulse onset detection using neighbor pulse-based signal enhancement.

Authors:  Peng Xu; Marvin Bergsneider; Xiao Hu
Journal:  Med Eng Phys       Date:  2008-07-15       Impact factor: 2.242

9.  Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves.

Authors:  Marit H N van Velzen; Arjo J Loeve; Sjoerd P Niehof; Egbert G Mik
Journal:  Med Biol Eng Comput       Date:  2017-03-30       Impact factor: 2.602

10.  Compatibility of pulse-pulse intervals with R-R intervals in assessing cardiac autonomic function and its relation to risks of atherosclerosis.

Authors:  Cheuk-Kwan Sun; Cyuan-Cin Liu; Wei-Min Liu; Hsien-Tsai Wu; Ruay-Ming Huang; An-Bang Liu
Journal:  Ci Ji Yi Xue Za Zhi       Date:  2019-02-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.