Literature DB >> 7595689

Evaluation of the pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children.

C F Wippermann1, D Schranz, R G Huth.   

Abstract

OBJECTIVE: Pulse arrival time (PAT), which is the interval between the R wave of the electrocardiogram (ECG) and the arrival of the pulse wave peripherally, has been reported to be suitable for use as an indirect measure of blood pressure change. The purpose of this study was to evaluate, in critically ill infants and children, the degree to which 1/PAT covaries with systolic, diastolic, and mean blood pressure, as well as heart rate.
METHODS: A laboratory device was used to calculate PAT in real time from the ECG and the plethysmographic curve of pulse oximetry used for routine monitoring. Calculated PAT and corresponding blood pressures and heart rate were stored on hard disk. A total of 15 critically ill patients, aged 6 days to 16 years, weighing 3 to 80 kg, were studied.
RESULTS: In all patients, one period of 11,000 to 36,000 beats could be evaluated. Mean correlation coefficients were best for systolic blood pressure (r = 0.73), followed by mean blood pressure (r = 0.68) and diastolic blood pressure (r = 0.61), and, finally, heart rate (r = 0.52). In 7 patients, the correlation coefficient for systolic blood pressure was > 0.9; but, in 4 patients, it was < 0.5.
CONCLUSIONS: We conclude that the correlation between 1/PAT and systolic blood pressure is not strong enough to serve as a marker for blood pressure changes in critically ill infants and children. This may be due to changes of the preejection period, which is part of the PAT.

Entities:  

Mesh:

Year:  1995        PMID: 7595689     DOI: 10.1007/BF01616991

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  16 in total

1.  THE CONTINUOUS MEASUREMENT OF ARTERIAL PULSE WAVE VELOCITY.

Authors:  G WELTMAN
Journal:  Med Electron Biol Eng       Date:  1964-04

2.  Pre-ejection period: measuring beta-adrenergic influences upon the heart.

Authors:  D B Newlin; R W Levenson
Journal:  Psychophysiology       Date:  1979-11       Impact factor: 4.016

3.  The effect of variations in blood-pressure on pulse wave velocity in the brachial artery in man.

Authors:  S K Hickson; B A McSwiney
Journal:  J Physiol       Date:  1924-10-09       Impact factor: 5.182

4.  Measurement of pulse-wave velocity using a beat-sampling technique.

Authors:  J D Pruett; J D Bourland; L A Geddes
Journal:  Ann Biomed Eng       Date:  1988       Impact factor: 3.934

5.  Relationship between pulse-wave velocity and arterial elasticity.

Authors:  F J Callaghan; L A Geddes; C F Babbs; J D Bourland
Journal:  Med Biol Eng Comput       Date:  1986-05       Impact factor: 2.602

6.  Systolic time intervals as measures of the contractile state of the left ventricular myocardium in man.

Authors:  S S Ahmed; G E Levinson; C J Schwartz; P O Ettinger
Journal:  Circulation       Date:  1972-09       Impact factor: 29.690

7.  Effects of anesthesia and related procedures on arterial pressure wave arrival times.

Authors:  J B Henderson; S Rodbard; H T Morse
Journal:  Anesth Analg       Date:  1972 Nov-Dec       Impact factor: 5.108

8.  Influence of amyl nitrite inhalation on the systolic time intervals in normal subjects and in patients with ischemic heart disease.

Authors:  T Sawayama; M Ochiai; S Marumoto; T Matsuura; I Niki
Journal:  Circulation       Date:  1969-09       Impact factor: 29.690

9.  The covariation of blood pressure and pulse transit time in hypertensive patients.

Authors:  R A Allen; J A Schneider; D M Davidson; M A Winchester; C B Taylor
Journal:  Psychophysiology       Date:  1981-05       Impact factor: 4.016

10.  Pulse transit time and blood pressure: an intensive analysis.

Authors:  J D Lane; L Greenstadt; D Shapiro; E Rubinstein
Journal:  Psychophysiology       Date:  1983-01       Impact factor: 4.016

View more
  10 in total

1.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration.

Authors:  W Chen; T Kobayashi; S Ichikawa; Y Takeuchi; T Togawa
Journal:  Med Biol Eng Comput       Date:  2000-09       Impact factor: 2.602

2.  The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs.

Authors:  R Ochiai; J Takeda; H Hosaka; Y Sugo; R Tanaka; T Soma
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

3.  Global versus local linear beat-to-beat analysis of the relationship between arterial pressure and pulse transit time during dynamic exercise.

Authors:  A Porta; C Gasperi; G Nollo; D Lucini; P Pizzinelli; R Antolini; M Pagani
Journal:  Med Biol Eng Comput       Date:  2006-03-23       Impact factor: 2.602

4.  Non-constrained blood pressure monitoring using ECG and PPG for personal healthcare.

Authors:  Youngzoon Yoon; Jung H Cho; Gilwon Yoon
Journal:  J Med Syst       Date:  2009-08       Impact factor: 4.460

Review 5.  Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Authors:  Jochanan E Naschitz; Stanislas Bezobchuk; Renata Mussafia-Priselac; Scott Sundick; Daniel Dreyfuss; Igal Khorshidi; Argyro Karidis; Hagit Manor; Mihael Nagar; Elisabeth Rubin Peck; Shannon Peck; Shimon Storch; Itzhak Rosner; Luis Gaitini
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

6.  Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method.

Authors:  Heiko Gesche; Detlef Grosskurth; Gert Küchler; Andreas Patzak
Journal:  Eur J Appl Physiol       Date:  2011-05-10       Impact factor: 3.078

7.  Noninvasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients.

Authors:  Christer Ahlstrom; Anders Johansson; Fredrik Uhlin; Toste Länne; Per Ask
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

8.  Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study.

Authors:  Hangsik Shin; Se Dong Min
Journal:  Biomed Eng Online       Date:  2017-01-10       Impact factor: 2.819

9.  Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care.

Authors:  Ha Uk Chung; Bong Hoon Kim; Jong Yoon Lee; Jungyup Lee; Zhaoqian Xie; Erin M Ibler; KunHyuck Lee; Anthony Banks; Ji Yoon Jeong; Jongwon Kim; Christopher Ogle; Dominic Grande; Yongjoon Yu; Hokyung Jang; Pourya Assem; Dennis Ryu; Jean Won Kwak; Myeong Namkoong; Jun Bin Park; Yechan Lee; Do Hoon Kim; Arin Ryu; Jaeseok Jeong; Kevin You; Bowen Ji; Zhuangjian Liu; Qingze Huo; Xue Feng; Yujun Deng; Yeshou Xu; Kyung-In Jang; Jeonghyun Kim; Yihui Zhang; Roozbeh Ghaffari; Casey M Rand; Molly Schau; Aaron Hamvas; Debra E Weese-Mayer; Yonggang Huang; Seung Min Lee; Chi Hwan Lee; Naresh R Shanbhag; Amy S Paller; Shuai Xu; John A Rogers
Journal:  Science       Date:  2019-03-01       Impact factor: 47.728

10.  A blood pressure monitoring method for stroke management.

Authors:  Heather Ting Ma
Journal:  Biomed Res Int       Date:  2014-08-17       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.