Literature DB >> 26233207

Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging.

Karen Van Audenhaege1, Roel Van Holen1, Stefaan Vandenberghe1, Christian Vanhove1, Scott D Metzler2, Stephen C Moore3.   

Abstract

In single photon emission computed tomography, the choice of the collimator has a major impact on the sensitivity and resolution of the system. Traditional parallel-hole and fan-beam collimators used in clinical practice, for example, have a relatively poor sensitivity and subcentimeter spatial resolution, while in small-animal imaging, pinhole collimators are used to obtain submillimeter resolution and multiple pinholes are often combined to increase sensitivity. This paper reviews methods for production, sensitivity maximization, and task-based optimization of collimation for both clinical and preclinical imaging applications. New opportunities for improved collimation are now arising primarily because of (i) new collimator-production techniques and (ii) detectors with improved intrinsic spatial resolution that have recently become available. These new technologies are expected to impact the design of collimators in the future. The authors also discuss concepts like septal penetration, high-resolution applications, multiplexing, sampling completeness, and adaptive systems, and the authors conclude with an example of an optimization study for a parallel-hole, fan-beam, cone-beam, and multiple-pinhole collimator for different applications.

Mesh:

Year:  2015        PMID: 26233207      PMCID: PMC5148182          DOI: 10.1118/1.4927061

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  115 in total

1.  Image reconstruction algorithm for a rotating slat collimator.

Authors:  Gengsheng L Zeng; Daniel Gagnon; Christopher G Matthews; Jeffery A Kolthammer; Jason D Radachy; William G Hawkins
Journal:  Med Phys       Date:  2002-07       Impact factor: 4.071

2.  Myocardial perfusion SPECT using a rotating multi-segment slant-hole collimator.

Authors:  Chi Liu; Jingyan Xu; Benjamin M W Tsui
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential.

Authors:  Wei Chang; Caesar E Ordonez; Haoning Liang; Yusheng Li; Jingai Liu
Journal:  IEEE Trans Nucl Sci       Date:  2009-10-06       Impact factor: 1.679

Review 4.  Small animal SPECT and its place in the matrix of molecular imaging technologies.

Authors:  Steven R Meikle; Peter Kench; Michael Kassiou; Richard B Banati
Journal:  Phys Med Biol       Date:  2005-10-24       Impact factor: 3.609

5.  Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging--a simulation study.

Authors:  Zixiong Cao; Girish Bal; Roberto Accorsi; Paul D Acton
Journal:  Phys Med Biol       Date:  2005-09-21       Impact factor: 3.609

6.  An analytic model of pinhole aperture penetration for 3D pinhole SPECT image reconstruction.

Authors:  M F Smith; R J Jaszczak
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  The evaluation of data completeness and image quality in multiplexing multi-pinhole SPECT.

Authors:  Karen Van Audenhaege; Christian Vanhove; Stefaan Vandenberghe; Roel Van Holen
Journal:  IEEE Trans Med Imaging       Date:  2014-10-01       Impact factor: 10.048

8.  Three-dimensional SPECT reconstruction of combined cone beam and parallel beam data.

Authors:  R J Jaszczak; J Li; H Wang; R E Coleman
Journal:  Phys Med Biol       Date:  1992-03       Impact factor: 3.609

9.  Design and Validation of an Adaptive SPECT System: AdaptiSPECT.

Authors:  Roel Van Holen; Jared W Moore; Eric W Clarkson; Lars R Furenlid; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10-30

10.  Optimal design of anger camera for bremsstrahlung imaging: monte carlo evaluation.

Authors:  Stephan Walrand; Michel Hesse; Randy Wojcik; Renaud Lhommel; François Jamar
Journal:  Front Oncol       Date:  2014-06-13       Impact factor: 6.244

View more
  11 in total

1.  Characterization of "γ-Eye": a Low-Cost Benchtop Mouse-Sized Gamma Camera for Dynamic and Static Imaging Studies.

Authors:  Maria Georgiou; Eleftherios Fysikopoulos; Konstantinos Mikropoulos; Eirini Fragogeorgi; George Loudos
Journal:  Mol Imaging Biol       Date:  2017-06       Impact factor: 3.488

Review 2.  Positron Emission Tomography in the Neuroimaging of Autism Spectrum Disorder: A Review.

Authors:  Zhiqiang Tan; Huiyi Wei; Xiubao Song; Wangxiang Mai; Jiajian Yan; Weijian Ye; Xueying Ling; Lu Hou; Shaojuan Zhang; Sen Yan; Hao Xu; Lu Wang
Journal:  Front Neurosci       Date:  2022-04-13       Impact factor: 5.152

3.  Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Arda Konik; Timothy J Fromme; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

4.  Development of clinical simultaneous SPECT/MRI.

Authors:  Brian F Hutton; Michele Occhipinti; Andre Kuehne; Domokos Máthé; Noémi Kovács; Helmar Waiczies; Kjell Erlandsson; Debora Salvado; Marco Carminati; Giovanni L Montagnani; Susan C Short; Luisa Ottobrini; Pieter van Mullekom; Claudio Piemonte; Tamas Bukki; Zoltan Nyitrai; Zoltan Papp; Kalman Nagy; Thoralf Niendorf; Irene de Francesco; Carlo Fiorini
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

Review 5.  Advantages and Limitations of Current Techniques for Analyzing the Biodistribution of Nanoparticles.

Authors:  Lauren Arms; Doug W Smith; Jamie Flynn; William Palmer; Antony Martin; Ameha Woldu; Susan Hua
Journal:  Front Pharmacol       Date:  2018-08-14       Impact factor: 5.810

6.  Multiple-pinhole collimators improve intra- and between-rater agreement and the certainty of the visual interpretation in dopamine transporter SPECT.

Authors:  Franziska Mathies; Ivayla Apostolova; Lena Dierck; Janin Jacobi; Katja Kuen; Markus Sauer; Michael Schenk; Susanne Klutmann; Attila Forgács; Ralph Buchert
Journal:  EJNMMI Res       Date:  2022-08-17       Impact factor: 3.434

7.  Gamma Camera Imaging with Rotating Multi-Pinhole Collimator. A Monte Carlo Feasibility Study.

Authors:  Victor Ilisie; Laura Moliner; Constantino Morera; Johan Nuyts; José María Benlloch
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

Review 8.  Current and Future Theranostic Applications of the Lipid-Calcium-Phosphate Nanoparticle Platform.

Authors:  Andrew B Satterlee; Leaf Huang
Journal:  Theranostics       Date:  2016-04-27       Impact factor: 11.556

9.  Monte Carlo-based quantitative pinhole SPECT reconstruction using a ray-tracing back-projector.

Authors:  Mikael Peterson; Johan Gustafsson; Michael Ljungberg
Journal:  EJNMMI Phys       Date:  2017-12-15

10.  Design Study of an Ultrahigh Resolution Brain SPECT System Using a Synthetic Compound-Eye Camera Design With Micro-Slit and Micro-Ring Apertures.

Authors:  Elena Maria Zannoni; Can Yang; Ling-Jian Meng
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.