Literature DB >> 17110782

Small nodule detectability evaluation using a generalized scan-statistic model.

Lucreţiu M Popescu1, Robert M Lewitt.   

Abstract

In this paper is investigated the use of the scan statistic for evaluating the detectability of small nodules in medical images. The scan-statistic method is often used in applications in which random fields must be searched for abnormal local features. Several results of the detection with localization theory are reviewed and a generalization is presented using the noise nodule distribution obtained by scanning arbitrary areas. One benefit of the noise nodule model is that it enables determination of the scan-statistic distribution by using only a few image samples in a way suitable both for simulation and experimental setups. Also, based on the noise nodule model, the case of multiple targets per image is addressed and an image abnormality test using the likelihood ratio and an alternative test using multiple decision thresholds are derived. The results obtained reveal that in the case of low contrast nodules or multiple nodules the usual test strategy based on a single decision threshold underperforms compared with the alternative tests. That is a consequence of the fact that not only the contrast or the size, but also the number of suspicious nodules is a clue indicating the image abnormality. In the case of the likelihood ratio test, the multiple clues are unified in a single decision variable. Other tests that process multiple clues differently do not necessarily produce a unique ROC curve, as shown in examples using a test involving two decision thresholds. We present examples with two-dimensional time-of-flight (TOF) and non-TOF PET image sets analysed using the scan statistic for different search areas, as well as the fixed position observer.

Mesh:

Year:  2006        PMID: 17110782     DOI: 10.1088/0031-9155/51/23/020

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Application of a generalized scan statistic model to evaluate TOF PET images.

Authors:  Suleman Surti; Joel S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2011       Impact factor: 1.679

2.  Model for the detection of signals in images with multiple suspicious locations.

Authors:  Lucreţiu M Popescu
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

3.  Optimization of time-of-flight reconstruction on Philips GEMINI TF.

Authors:  Stefaan Vandenberghe; Larry van Elmbt; Michel Guerchaft; Enrico Clementel; Jeroen Verhaeghe; Anne Bol; Ignace Lemahieu; Max Lonneux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

4.  Aperture optimization in emission imaging using ideal observers for joint detection and localization.

Authors:  Lili Zhou; Parmeshwar Khurd; Santosh Kulkarni; Anand Rangarajan; Gene Gindi
Journal:  Phys Med Biol       Date:  2008-03-26       Impact factor: 3.609

5.  Virtual assessment of stereoscopic viewing of digital breast tomosynthesis projection images.

Authors:  Gezheng Wen; Ho-Chang Chang; Jacob Reinhold; Joseph Y Lo; Mia K Markey
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-17

6.  Impact of detector design on imaging performance of a long axial field-of-view, whole-body PET scanner.

Authors:  S Surti; J S Karp
Journal:  Phys Med Biol       Date:  2015-06-25       Impact factor: 3.609

7.  Operating characteristics predicted by models for diagnostic tasks involving lesion localization.

Authors:  D P Chakraborty; Hong-Jun Yoon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

8.  The efficiency of the human observer for lesion detection and localization in emission tomography.

Authors:  Bin Liu; Lili Zhou; Santosh Kulkarni; Gene Gindi
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

9.  Study of PET scanner designs using clinical metrics to optimize the scanner axial FOV and crystal thickness.

Authors:  S Surti; M E Werner; J S Karp
Journal:  Phys Med Biol       Date:  2013-05-17       Impact factor: 3.609

10.  Correlation between model observer and human observer performance in CT imaging when lesion location is uncertain.

Authors:  Shuai Leng; Lifeng Yu; Yi Zhang; Rickey Carter; Alicia Y Toledano; Cynthia H McCollough
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

View more