Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration.

A N Primak1, J C Ramirez Giraldo, X Liu, L Yu, C H McCollough.   

Abstract

The use of additional spectral filtration for dual-energy (DE) imaging using a dual-source CT (DSCT) system was investigated and its effect on the material-specific DE(ratio) was evaluated for several clinically relevant materials. The x-ray spectra, data acquisition, and reconstruction processes for a DSCT system (Siemens Definition) were simulated using information provided by the system manufacturer, resulting in virtual DE images. The factory-installed filtration for the 80 kV spectrum was left unchanged to avoid any further reductions in tube output, and only the filtration for the high-energy spectrum was modified. Only practical single-element filter materials within the atomic number range of 40 < or = Z < or = 83 were evaluated, with the aim of maximizing the separation between the two spectra, while maintaining similar noise levels for high- and low-energy images acquired at the same tube current. The differences between mean energies and the ratio of the 140 and 80 kV detector signals, each integrated below 80 keV, were evaluated. The simulations were performed for three attenuation scenarios: Head, body, and large body. The large body scenario was evaluated for the DE acquisition mode using the 100 and 140 kV spectra. The DE(ratio) for calcium hydroxyapatite (simulating bone or calcifications), iodine, and iron were determined for CT images simulated using the modified and factory-installed filtration. Several filter materials were found to perform well at proper thicknesses, with tin being a good practical choice. When image noise was matched between the low- and high-energy images, the spectral difference in mean absorbed energy using tin was increased from 25.7 to 42.7 keV (head), from 28.6 to 44.1 keV (body), and from 20.2 to 30.2 keV (large body). The overlap of the signal spectra for energies below 80 keV was reduced from 78% to 31% (head), from 93% to 27% (body), and from 106% to 79% (large body). The DE(ratio) for the body attenuation scenario increased from 1.45 to 1.91 (calcium), from 1.84 to 3.39 (iodine), and from 1.73 to 2.93 (iron) with the additional tin filtration compared to the factory filtration. This use of additional filtration for one of the x-ray tubes used in dual-source DECT dramatically increased the difference between material-specific DE ratios, e.g., from 0.39 to 1.48 for calcium and iodine or from 0.28 to 1.02 for calcium and iron. Because the ability to discriminate between different materials in DE imaging depends primarily on the differences in DE ratios, this increase is expected to improve the performance of any material-specific DECT imaging task. Furthermore, for the large patient size and in conjunction with a 100/140 kV acquisition, the use of additional filtration decreased noise in the low-energy images and increased contrast in the DE image relative to that obtained with 80/140 kV and no additional filtration.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19472643      PMCID: PMC2719491          DOI: 10.1118/1.3083567

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  26 in total

Review 1.  X-ray computed tomography.

Authors:  Willi A Kalender
Journal:  Phys Med Biol       Date:  2006-06-20       Impact factor: 3.609

2.  Material differentiation by dual energy CT: initial experience.

Authors:  Thorsten R C Johnson; Bernhard Krauss; Martin Sedlmair; Michael Grasruck; Herbert Bruder; Dominik Morhard; Christian Fink; Sabine Weckbach; Miriam Lenhard; Bernhard Schmidt; Thomas Flohr; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-12-07       Impact factor: 5.315

3.  Optimization of image acquisition techniques for dual-energy imaging of the chest.

Authors:  N A Shkumat; J H Siewerdsen; A C Dhanantwari; D B Williams; S Richard; N S Paul; J Yorkston; R Van Metter
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

4.  First performance evaluation of a dual-source CT (DSCT) system.

Authors:  Thomas G Flohr; Cynthia H McCollough; Herbert Bruder; Martin Petersilka; Klaus Gruber; Christoph Süss; Michael Grasruck; Karl Stierstorfer; Bernhard Krauss; Rainer Raupach; Andrew N Primak; Axel Küttner; Stefan Achenbach; Christoph Becker; Andreas Kopp; Bernd M Ohnesorge
Journal:  Eur Radiol       Date:  2005-12-10       Impact factor: 5.315

5.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

Authors:  J M Boone; J A Seibert
Journal:  Med Phys       Date:  1997-11       Impact factor: 4.071

6.  Estimation of a photon energy spectrum for a computed tomography scanner.

Authors:  C Ruth; P M Joseph
Journal:  Med Phys       Date:  1997-05       Impact factor: 4.071

7.  Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies.

Authors:  W A Kalender; W H Perman; J R Vetter; E Klotz
Journal:  Med Phys       Date:  1986 May-Jun       Impact factor: 4.071

8.  Dual-energy mammography: a detector analysis.

Authors:  J M Boone; G S Shaber; M Tecotzky
Journal:  Med Phys       Date:  1990 Jul-Aug       Impact factor: 4.071

9.  Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease.

Authors:  Hans Scheffel; Paul Stolzmann; Thomas Frauenfelder; Thomas Schertler; Lotus Desbiolles; Sebastian Leschka; Borut Marincek; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-12       Impact factor: 6.016

10.  Quantitative X-ray imaging of intraplaque hemorrhage in aortas of apoE(-/-)/LDL(-/-) double knockout mice.

Authors:  Alexander C Langheinrich; Agata Michniewicz; Daniel G Sedding; Barry Lai; Steven M Jorgensen; Rainer M Bohle; Erik L Ritman
Journal:  Invest Radiol       Date:  2007-05       Impact factor: 6.016

View more
  67 in total

1.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

3.  Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study.

Authors:  Christoph Karlo; Arno Lauber; Robert Paul Götti; Stephan Baumüller; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Bernhard Schmidt; Borut Marincek; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-08-15       Impact factor: 5.315

4.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

5.  Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: comparison of analytic and polyenergetic statistical reconstruction algorithms.

Authors:  Joshua D Evans; Bruce R Whiting; Joseph A O'Sullivan; David G Politte; Paul H Klahr; Yaduo Yu; Jeffrey F Williamson
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

6.  Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition.

Authors:  Xin Liu; Lifeng Yu; Andrew N Primak; Cynthia H McCollough
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

7.  Material separation in x-ray CT with energy resolved photon-counting detectors.

Authors:  Xiaolan Wang; Dirk Meier; Katsuyuki Taguchi; Douglas J Wagenaar; Bradley E Patt; Eric C Frey
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

8.  Quantification of multiple mixed contrast and tissue compositions using photon-counting spectral computed tomography.

Authors:  Tyler E Curtis; Ryan K Roeder
Journal:  J Med Imaging (Bellingham)       Date:  2019-02-11

9.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

10.  Spectral CT imaging of intranodular hemorrhage in cases with challenging benign thyroid nodules.

Authors:  Ming Li; Xiangpeng Zheng; Feng Gao; Li Xiao; Yanqing Hua
Journal:  Radiol Med       Date:  2015-11-27       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.