Literature DB >> 16341833

First performance evaluation of a dual-source CT (DSCT) system.

Thomas G Flohr1, Cynthia H McCollough, Herbert Bruder, Martin Petersilka, Klaus Gruber, Christoph Süss, Michael Grasruck, Karl Stierstorfer, Bernhard Krauss, Rainer Raupach, Andrew N Primak, Axel Küttner, Stefan Achenbach, Christoph Becker, Andreas Kopp, Bernd M Ohnesorge.   

Abstract

We present a performance evaluation of a recently introduced dual-source computed tomography (DSCT) system equipped with two X-ray tubes and two corresponding detectors, mounted onto the rotating gantry with an angular offset of 90 degrees . We introduce the system concept and derive its consequences and potential benefits for electrocardiograph [corrected] (ECG)-controlled cardiac CT and for general radiology applications. We evaluate both temporal and spatial resolution by means of phantom scans. We present first patient scans to illustrate the performance of DSCT for ECG-gated cardiac imaging, and we demonstrate first results using a dual-energy acquisition mode. Using ECG-gated single-segment reconstruction, the DSCT system provides 83 ms temporal resolution independent of the patient's heart rate for coronary CT angiography (CTA) and evaluation of basic functional parameters. With dual-segment reconstruction, the mean temporal resolution is 60 ms (minimum temporal resolution 42 ms) for advanced functional evaluation. The z-flying focal spot technique implemented in the evaluated DSCT system allows 0.4 mm cylinders to be resolved at all heart rates. First clinical experience shows a considerably increased robustness for the imaging of patients with high heart rates. As a potential application of the dual-energy acquisition mode, the automatic separation of bones and iodine-filled vessels is demonstrated.

Entities:  

Mesh:

Year:  2005        PMID: 16341833     DOI: 10.1007/s00330-005-2919-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  41 in total

1.  Noninvasive detection of coronary artery stenosis by multislice helical computed tomography.

Authors:  A Knez; C Becker; B Ohnesorge; R Haberl; M Reiser; G Steinbeck
Journal:  Circulation       Date:  2000-06-13       Impact factor: 29.690

2.  Accuracy of density measurements within plaques located in artificial coronary arteries by X-ray multislice CT: results of a phantom study.

Authors:  S Schroeder; T Flohr; A F Kopp; C Meisner; A Kuettner; C Herdeg; A Baumbach; B Ohnesorge
Journal:  J Comput Assist Tomogr       Date:  2001 Nov-Dec       Impact factor: 1.826

3.  Coronary angiography with multi-slice computed tomography.

Authors:  K Nieman; M Oudkerk; B J Rensing; P van Ooijen; A Munne; R J van Geuns; P J de Feyter
Journal:  Lancet       Date:  2001-02-24       Impact factor: 79.321

4.  Coronary artery calcium measurement: agreement of multirow detector and electron beam CT.

Authors:  C R Becker; T Kleffel; A Crispin; A Knez; J Young; U J Schoepf; R Haberl; M F Reiser
Journal:  AJR Am J Roentgenol       Date:  2001-05       Impact factor: 3.959

5.  Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT.

Authors:  Andreas F Kopp; Bernd Ohnesorge; Christoph Becker; Stephen Schröder; Martin Heuschmid; Axel Küttner; Ronald Kuzo; Claus D Claussen
Journal:  Radiology       Date:  2002-10       Impact factor: 11.105

6.  Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution.

Authors:  A Kuettner; T Beck; T Drosch; K Kettering; M Heuschmid; C Burgstahler; C D Claussen; A F Kopp; S Schroeder
Journal:  Heart       Date:  2005-07       Impact factor: 5.994

Review 7.  The technical design and performance of ultrafast computed tomography.

Authors:  C H McCollough; R L Morin
Journal:  Radiol Clin North Am       Date:  1994-05       Impact factor: 2.303

8.  Optimal short scan convolution reconstruction for fanbeam CT.

Authors:  D L Parker
Journal:  Med Phys       Date:  1982 Mar-Apr       Impact factor: 4.071

9.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

10.  Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determination of vertebral bone mineral content.

Authors:  J R Vetter; W H Perman; W A Kalender; R B Mazess; J E Holden
Journal:  Med Phys       Date:  1986 May-Jun       Impact factor: 4.071

View more
  333 in total

1.  Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography.

Authors:  Satoshi Okayama; Ayako Seno; Tsunenari Soeda; Yasuhiro Takami; Rika Kawakami; Satoshi Somekawa; Ken-Ichi Ishigami; Yukiji Takeda; Hiroyuki Kawata; Manabu Horii; Shiro Uemura; Yoshihiko Saito
Journal:  Int J Cardiovasc Imaging       Date:  2011-06-03       Impact factor: 2.357

2.  [Principles of multidetector-row computed tomography. Part 2: determinants of radiation exposure and current technical developments].

Authors:  W Stiller
Journal:  Radiologe       Date:  2011-12       Impact factor: 0.635

3.  A strategy to decrease partial scan reconstruction artifacts in myocardial perfusion CT: phantom and in vivo evaluation.

Authors:  Juan C Ramirez-Giraldo; Lifeng Yu; Birgit Kantor; Erik L Ritman; Cynthia H McCollough
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

Review 4.  Coronary artery anatomy and variants.

Authors:  Roberto Malagò; Andrea Pezzato; Camilla Barbiani; Ugolino Alfonsi; Lisa Nicolì; Giuliana Caliari; Roberto Pozzi Mucelli
Journal:  Pediatr Radiol       Date:  2011-11-30

Review 5.  Dual-energy computed tomography applications in uroradiology.

Authors:  Jong Park; Hersh Chandarana; Michael Macari; Alec J Megibow
Journal:  Curr Urol Rep       Date:  2012-02       Impact factor: 3.092

Review 6.  Multislice computed tomography angiography in the diagnosis of cardiovascular disease: 3D visualizations.

Authors:  Zhonghua Sun
Journal:  Front Med       Date:  2011-10-02       Impact factor: 4.592

Review 7.  Anomalous origination of a coronary artery from the opposite sinus.

Authors:  Joanna C E Lim; Andy Beale; Steve Ramcharitar
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

8.  Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets.

Authors:  Shuai Leng; Wei Zhou; Zhicong Yu; Ahmed Halaweish; Bernhard Krauss; Bernhard Schmidt; Lifeng Yu; Steffen Kappler; Cynthia McCollough
Journal:  Phys Med Biol       Date:  2017-08-21       Impact factor: 3.609

9.  Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts.

Authors:  Kai Roman Laukamp; David Zopfs; Simon Lennartz; Lenhard Pennig; David Maintz; Jan Borggrefe; Nils Große Hokamp
Journal:  Eur Radiol       Date:  2019-01-16       Impact factor: 5.315

Review 10.  Recent and future directions in CT imaging.

Authors:  Norbert J Pelc
Journal:  Ann Biomed Eng       Date:  2014-01-17       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.