Estimation of a photon energy spectrum for a computed tomography scanner.

C Ruth1, P M Joseph.   

Abstract

Estimated photon energy spectra are derived from transmission measurements using aluminium, copper, and sodium iodide absorbers. Two spectral models are proposed. One is based on a previously published model that analyzes the electron's penetration into the anode, and the production and attenuation of bremsstrahlung photons. The second model does not include details regarding the underlying physics, but treats the spectrum as a sum of delta functions. A nonlinear regularization method is used to overcome ill conditioning in the second model. Both models fit the transmission data to an accuracy of 0.30%, which is consistent with the experimental error. A quantitative comparison of the models is made by calculating the average and variance (over the derived energy spectra) of several relevant mass attenuation coefficients. The maximum variation in the average and variance was 1.5% and 3.2%, respectively, indicating that the spectra exhibit similar attenuation and beam hardening properties. The spectra were tested with a simulation that predicts scanner CT numbers for phantom measurements consisting of dilutions of sodium iodide in a water equivalent background. The agreement between simulation and experiment ranged from 1.5% at 220 HU to 4.4% at 1700 HU.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9167160     DOI: 10.1118/1.598159

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration.

Authors:  A N Primak; J C Ramirez Giraldo; X Liu; L Yu; C H McCollough
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

2.  CT scanner x-ray spectrum estimation from transmission measurements.

Authors:  Xinhui Duan; Jia Wang; Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

3.  Real-time dosimeter employed to evaluate the half-value layer in CT.

Authors:  Sarah E McKenney; J Anthony Seibert; George W Burkett; Dale Gelskey; Paul B Sunde; James D Newman; John M Boone
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

4.  Dual-Energy Technique at Low Tube Voltages for Small Animal Imaging.

Authors:  Seungryong Cho; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

5.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

6.  Statistical sinogram restoration in dual-energy CT for PET attenuation correction.

Authors:  Joonki Noh; Jeffrey A Fessler; Paul E Kinahan
Journal:  IEEE Trans Med Imaging       Date:  2009-03-24       Impact factor: 10.048

7.  Estimating the spectrum in computed tomography via Kullback-Leibler divergence constrained optimization.

Authors:  Wooseok Ha; Emil Y Sidky; Rina Foygel Barber; Taly Gilat Schmidt; Xiaochuan Pan
Journal:  Med Phys       Date:  2018-12-13       Impact factor: 4.071

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.