Literature DB >> 16790909

X-ray computed tomography.

Willi A Kalender1.   

Abstract

X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.

Mesh:

Year:  2006        PMID: 16790909     DOI: 10.1088/0031-9155/51/13/R03

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  73 in total

1.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

Review 2.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

3.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration.

Authors:  A N Primak; J C Ramirez Giraldo; X Liu; L Yu; C H McCollough
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

4.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

5.  Characterization and identification of spatial artifacts during 4D-CT imaging.

Authors:  Dongfeng Han; John Bayouth; Sudershan Bhatia; Milan Sonka; Xiaodong Wu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 6.  Light sheet fluorescence microscopy: a review.

Authors:  Peter A Santi
Journal:  J Histochem Cytochem       Date:  2011-02       Impact factor: 2.479

7.  Live augmented reality: a new visualization method for laparoscopic surgery using continuous volumetric computed tomography.

Authors:  Raj Shekhar; Omkar Dandekar; Venkatesh Bhat; Mathew Philip; Peng Lei; Carlos Godinez; Erica Sutton; Ivan George; Steven Kavic; Reuben Mezrich; Adrian Park
Journal:  Surg Endosc       Date:  2010-02-21       Impact factor: 4.584

Review 8.  Newer CT applications and their alternatives: what is appropriate in children?

Authors:  R Paul Guillerman
Journal:  Pediatr Radiol       Date:  2011-08-17

9.  Quantification of multiple mixed contrast and tissue compositions using photon-counting spectral computed tomography.

Authors:  Tyler E Curtis; Ryan K Roeder
Journal:  J Med Imaging (Bellingham)       Date:  2019-02-11

10.  Diffuse optical tomography to measure functional changes during motor tasks: a motor imagery study.

Authors:  Estefania Hernandez-Martin; Francisco Marcano; Cristian Modroño; Niels Janssen; Jose Luis González-Mora
Journal:  Biomed Opt Express       Date:  2020-10-05       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.