Literature DB >> 19363640

High cup angle and microseparation increase the wear of hip surface replacements.

Ian J Leslie1, Sophie Williams, Graham Isaac, Eileen Ingham, John Fisher.   

Abstract

High wear rates and high patient ion levels have been associated with high (> 55 degrees) cup inclination angles for metal-on-metal surface replacements. Wear rates and patterns have been simulated for ceramic-on-ceramic bearings by applying microseparation to replicate head offset deficiency. We tested 39-mm metal-on-metal surface replacements (n = 5) in a hip simulator with (A) an increased cup inclination angle of 60 degrees and (B) an increased cup inclination angle and microseparation over 2 million cycles. (A) resulted in a ninefold increase in wear rate and (B) resulted in a 17-fold increase in wear rate compared to a standard gait condition study. Wear particles produced under microseparation conditions were larger than those produced under standard conditions but of similar shape (round to oval). The data suggest both head and cup position influence the wear of surface replacements; we believe it likely bearings with high wear either have a high cup inclination angle, an offset deficient head, or a combination of both.

Entities:  

Mesh:

Year:  2009        PMID: 19363640      PMCID: PMC2866926          DOI: 10.1007/s11999-009-0830-x

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

1.  A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates.

Authors:  P S Barbour; M H Stone; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  1999       Impact factor: 1.617

2.  The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator.

Authors:  J E Nevelos; E Ingham; C Doyle; A B Nevelos; J Fisher
Journal:  J Mater Sci Mater Med       Date:  2001-02       Impact factor: 3.896

3.  Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure.

Authors:  L Kang; A L Galvin; T D Brown; J Fisher; Z-M Jin
Journal:  Proc Inst Mech Eng H       Date:  2008-10       Impact factor: 1.617

4.  Modes of implant failure after hip resurfacing: morphological and wear analysis of 267 retrieval specimens.

Authors:  Michael M Morlock; Nick Bishop; Jozef Zustin; Michael Hahn; Wolfgang Rüther; Michael Amling
Journal:  J Bone Joint Surg Am       Date:  2008-08       Impact factor: 5.284

5.  Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components.

Authors:  R De Haan; P A Campbell; E P Su; K A De Smet
Journal:  J Bone Joint Surg Br       Date:  2008-09

6.  Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses.

Authors:  J E Nevelos; E Ingham; C Doyle; J Fisher; A B Nevelos
Journal:  Biomaterials       Date:  1999-10       Impact factor: 12.479

7.  Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time.

Authors:  I Catelas; P A Campbell; J D Bobyn; J B Medley; O L Huk
Journal:  Proc Inst Mech Eng H       Date:  2006-02       Impact factor: 1.617

8.  Pseudotumours associated with metal-on-metal hip resurfacings.

Authors:  H Pandit; S Glyn-Jones; P McLardy-Smith; R Gundle; D Whitwell; C L M Gibbons; S Ostlere; N Athanasou; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2008-07

9.  Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity.

Authors:  Mauricio Silva; Eric F Shepherd; Walter O Jackson; Frederick J Dorey; Thomas P Schmalzried
Journal:  J Arthroplasty       Date:  2002-09       Impact factor: 4.757

10.  Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation.

Authors:  Christopher Brown; Sophie Williams; Joanne L Tipper; John Fisher; Eileen Ingham
Journal:  J Mater Sci Mater Med       Date:  2006-12-14       Impact factor: 4.727

View more
  42 in total

1.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  [Durom™ hip resurfacing. Short- to midterm clinical and radiological outcome].

Authors:  J Goronzy; M Stiehler; S Kirschner; K-P Günther
Journal:  Orthopade       Date:  2010-09       Impact factor: 1.087

Review 3.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

5.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

6.  Edge-loading severity as a function of cup lip radius in metal-on-metal total hips--a finite element analysis.

Authors:  Jacob M Elkins; Karen M Kruger; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-08-02       Impact factor: 3.494

7.  Using acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement.

Authors:  Junwei Li; Xu Gao; Guanghui Yang; Yanru Zhang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

Review 8.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

9.  The First SICOT Oral Presentation Award 2011: imageless computer-assisted femoral component positioning in hip resurfacing: a prospective randomised trial.

Authors:  Maik Stiehler; Jens Goronzy; Albrecht Hartmann; Frank Krummenauer; Klaus-Peter Günther
Journal:  Int Orthop       Date:  2013-02-06       Impact factor: 3.075

10.  Risk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.

Authors:  Ian C Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G Bowsher; Michelle Burgett; Thomas K Donaldson
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.