Literature DB >> 10509194

Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses.

J E Nevelos1, E Ingham, C Doyle, J Fisher, A B Nevelos.   

Abstract

This study analyses explanted prostheses from a single surgeon's 16-yr series of Mittelmeier cementless total hip replacements. The patient group was young (patients aged 15-60, average 40) and active. Revision was related to various factors. All components were measured using a Kemco 3D coordinate measurement machine. Wear surfaces and linear wear penetrations of 11 retrieved Mittelmeier Autophor ceramic hip components (average implantation time 8.6 yr, range 1-13 yr) were analysed and the different types of wear identified. Surface analysis was then performed using Talysurf contacting profilometry and scanning electron microscopy. Three types of wear were identified: low wear (1 case), stripe wear (6 cases) and severe wear (4 cases). Stripe wear was characterised as a stripe of worn area on the head up to 150 microns deep whilst the rest of the head showed very low wear. The cups in the stripe wear cases were worn over about 40-50% of the surface. Severe wear cases had very large areas of heavy wear and visible volume loss on both heads and cups. The four cases of severe wear were associated with abnormal clinical histories.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10509194     DOI: 10.1016/s0142-9612(99)00081-2

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  20 in total

1.  Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions.

Authors:  T Stewart; J Tipper; R Streicher; E Ingham; J Fisher
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

2.  Wear degradation of long-term in vivo exposed alumina-on-alumina hip joints: linking nanometer-scale phenomena to macroscopic joint design.

Authors:  Yasuhito Takahashi; Nobuhiko Sugano; Wenliang Zhu; Takashi Nishii; Takashi Sakai; Masaki Takao; Giuseppe Pezzotti
Journal:  J Mater Sci Mater Med       Date:  2011-11-22       Impact factor: 3.896

3.  High cup angle and microseparation increase the wear of hip surface replacements.

Authors:  Ian J Leslie; Sophie Williams; Graham Isaac; Eileen Ingham; John Fisher
Journal:  Clin Orthop Relat Res       Date:  2009-04-11       Impact factor: 4.176

Review 4.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

5.  In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report.

Authors:  Michel P Laurent; Robin Pourzal; Alfons Fischer; Kim C Bertin; Joshua J Jacobs; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-04-06       Impact factor: 5.284

6.  Titanium dioxide (TiO(2)) nanoparticles filled poly(D,L lactid acid) (PDLLA) matrix composites for bone tissue engineering.

Authors:  L-C Gerhardt; G M R Jell; A R Boccaccini
Journal:  J Mater Sci Mater Med       Date:  2007-01-09       Impact factor: 3.896

7.  Does acetabular inclination angle affect survivorship of alumina-ceramic articulations?

Authors:  Henning R Johansson; Aaron J Johnson; Michael G Zywiel; Marybeth Naughton; Michael A Mont; Peter M Bonutti
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

8.  Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis.

Authors:  Young-Hoo Kim; Yoowang Choi; Jun-Shik Kim
Journal:  Int Orthop       Date:  2009-09-26       Impact factor: 3.075

9.  Risk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.

Authors:  Ian C Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G Bowsher; Michelle Burgett; Thomas K Donaldson
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

10.  Is wear debris responsible for failure in alumina-on-alumina implants?

Authors:  Lucia Savarino; Nicola Baldini; Gabriela Ciapetti; Andrea Pellacani; Armando Giunti
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more