Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time.

I Catelas1, P A Campbell, J D Bobyn, J B Medley, O L Huk.   

Abstract

Detailed characterization of wear particles is necessary to understand better the implant wear mechanisms and the periprosthetic tissue response. The purposes of the present study were to compare particle characteristics of current with older designs of metal-on-metal (MM) total hip replacements (THRs), and to determine the effect of implantation time on wear particle characteristics. Metal wear particles isolated from periprosthetic tissues from 19 patients with MM THRs of current and older designs and at different implantation times (very short, longer, and very long) were studied using transmission electron microscopy and energy dispersive X-ray analysis. The particles from the current design implants with implantation times of not more than 15 months (very short-term) were almost exclusively round to oval chromium oxide particles. In all other cases, although the predominance was still round to oval chromium oxide particles, greater proportions of cobalt-chromium-molybdenum (Co-Cr-Mo) particles, mainly needle-shaped, were detected. Very long-term THRs implanted for more than 20 years had the highest percentage of needle-shaped Co-Cr-Mo particles. Particle lengths were not markedly different between the different designs and implantation times except for the current design implants of not more than 15 months, which had a significantly smaller mean length of 39 nm. In conclusion, the implant design did not seem to have a significant influence on particle characteristics whereas the implantation time appeared to have the most effect on the particles. It should be noted that, because of the limited number of tissue retrievals available, some uncertainty remains regarding the generality of these findings.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16669387     DOI: 10.1243/09544119JEIM112

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  17 in total

1.  High cup angle and microseparation increase the wear of hip surface replacements.

Authors:  Ian J Leslie; Sophie Williams; Graham Isaac; Eileen Ingham; John Fisher
Journal:  Clin Orthop Relat Res       Date:  2009-04-11       Impact factor: 4.176

Review 2.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

Review 3.  New insights into wear and biological effects of metal-on-metal bearings.

Authors:  Isabelle Catelas; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

Review 4.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

5.  In-situ Generated Tribomaterial in Metal/Metal Contacts: current understanding and future implications for implants.

Authors:  N Espallargas; A Fischer; A Igual Muñoz; S Mischler; M A Wimmer
Journal:  Biotribology (Oxf)       Date:  2017-05-12

6.  The Hard on Hard Bearings in THA - Current concepts.

Authors:  P Gopinathan
Journal:  J Orthop       Date:  2014-09-19

7.  Characterization of Wear Particles Generated from CoCrMo Alloy under Sliding Wear Conditions.

Authors:  R Pourzal; I Catelas; R Theissmann; C Kaddick; A Fischer
Journal:  Wear       Date:  2011-07-29       Impact factor: 3.892

8.  Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms.

Authors:  Marco S Caicedo; Lauryn Samelko; Kyron McAllister; Joshua J Jacobs; Nadim J Hallab
Journal:  J Orthop Res       Date:  2013-06-21       Impact factor: 3.494

9.  A retrospective comparative study of mortality and causes of death among patients with metal-on-metal and metal-on-polyethylene total hip prostheses in primary osteoarthritis after a long-term follow-up.

Authors:  Tuomo Visuri; Håkan Borg; Pekka Pulkkinen; Pekka Paavolainen; Eero Pukkala
Journal:  BMC Musculoskelet Disord       Date:  2010-04-23       Impact factor: 2.362

10.  Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis.

Authors:  Jean-Yves Lazennec; Patrick Boyer; Joel Poupon; Marc-Antoine Rousseau; Carine Roy; Philippe Ravaud; Yves Catonné
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.