Literature DB >> 25784987

Using acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement.

Junwei Li1, Xu Gao1, Guanghui Yang2, Yanru Zhang3.   

Abstract

Positions of acetabular implant generally are considered to be major causative factors of dislocation. Accurate and consistent achievement of the preoperatively anticipated orientation of the acetabular cup is a great challenge in total hip replacement (THR). In the present study, we investigated the surgical application of acetabular fossa as a guide for anticipated inclination of uncemented cup, and evaluated its accuracy as an anatomic reference for achieving the preoperatively anticipated abduction of the acetabular cup in comparison with traditional device method on cadaveric specimens. Sixteen normal adult pelvic cadaveric specimens were collected. On each of the sixteen normal adult pelvic cadaveric specimens, acetabular fossa related anatomic sites were marked and studied on pelvic radiographs. Our results showed that there is close correlation between most medial aspect of acetabular sourcil and central axis of the acetabular cup at anticipated inclination of 40° ± 5°. And the fossa group can achieve the preoperatively anticipated cup abduction more accurately than the device group. The current results demonstrated that acetabular fossa can be a reasonable alternative, or as a complement to the currently used methods guiding total hip replacement.

Keywords:  Acetabular fossa; accuracy; anatomic reference; preoperative assessment; radiographic characteristics; total hip replacement

Year:  2015        PMID: 25784987      PMCID: PMC4358442     

Source DB:  PubMed          Journal:  Int J Clin Exp Med        ISSN: 1940-5901


  25 in total

1.  Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs.

Authors:  Maximilian Haenle; Wolfram Mittelmeier; Rodrigo Barbano; Klaus Wörtler; Roger Scholz; Rainer Bader
Journal:  Surg Radiol Anat       Date:  2010-06-25       Impact factor: 1.246

2.  High cup angle and microseparation increase the wear of hip surface replacements.

Authors:  Ian J Leslie; Sophie Williams; Graham Isaac; Eileen Ingham; John Fisher
Journal:  Clin Orthop Relat Res       Date:  2009-04-11       Impact factor: 4.176

Review 3.  Cup positioning in THA: current status and pitfalls. A systematic evaluation of the literature.

Authors:  J Beckmann; C Lüring; M Tingart; S Anders; J Grifka; F X Köck
Journal:  Arch Orthop Trauma Surg       Date:  2008-07-04       Impact factor: 3.067

4.  A systematic approach to the plain radiographic evaluation of the young adult hip.

Authors:  John C Clohisy; John C Carlisle; Paul E Beaulé; Young-Jo Kim; Robert T Trousdale; Rafael J Sierra; Michael Leunig; Perry L Schoenecker; Michael B Millis
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

5.  Are acetabular component alignment guides for total hip arthroplasty accurate?

Authors:  Yukihide Minoda; Kenji Ohzono; Masaharu Aihara; Naoya Umeda; Masuhiro Tomita; Keiko Hayakawa
Journal:  J Arthroplasty       Date:  2009-10-17       Impact factor: 4.757

6.  Position, orientation and component interaction in dislocation of the total hip prosthesis.

Authors:  K Herrlin; G Selvik; H Pettersson; P Kesek; R Onnerfält; A Ohlin
Journal:  Acta Radiol       Date:  1988 Jul-Aug       Impact factor: 1.990

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  Dislocation after total hip arthroplasty. Causes and prevention.

Authors:  D E McCollum; W J Gray
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

9.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

10.  The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment.

Authors:  A M DiGioia; B Jaramaz; M Blackwell; D A Simon; F Morgan; J E Moody; C Nikou; B D Colgan; C A Aston; R S Labarca; E Kischell; T Kanade
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

View more
  1 in total

1.  Mid-term and long-term results of restoring rotation center in revision hip arthroplasty.

Authors:  Heng Zhang; Jiansheng Zhou; Yang Liu; Jianzhong Guan; Hai Ding; Zhiyan Wang; Qirong Dong
Journal:  J Orthop Surg Res       Date:  2020-04-16       Impact factor: 2.359

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.