Literature DB >> 19361028

Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study.

Gerard J Myers1, Cheri Voorhees, Rob Haynes, Bob Eke.   

Abstract

During a previously published study on gaseous microemboli (GMEs) and perfusionist interventions, it was noted that emboli could be detected after the arterial filter when blood/air challenges entered the membrane oxygenator's integral cardiotomy. The findings indicated that further study into the oxygenator's integral cardiotomy reservoir was warranted. This is the first know published report that connects the vent return to GME activity after the arterial filter. To study the air handling ability of the membranes integral cardiotomy, an in vitro study was conducted on five hard shell coated membrane oxygenators (Terumo Capiox SX25, X coated; Sorin Synthesis, phosphorylcholine coated; Gish Vision, GBS coated; Medtronic Affinity NT, trillium coated; Maquet Quadrox, bioline coated). The oxygenators were matched with their own manufacturer's coated arterial filters (Medtronic 351T Arterial Filter, Sorin Synthesis Integrated Arterial Filter, Terumo CXAF200X Arterial Filter, Gish GAF40GBS-2 Arterial Filter, and Maquet Quart HBF140 Arterial Filter). There were three arms to the study, and three separate oxygenator/filter combinations were used in each arm. The first arm consisted of a pump flow of 4.0 L/min with only the filter purge blood entering the integral cardiotomy. In the second arm, 500 mL/min of simulated vent blood was added to the filter purge blood entering the integral cardiotomy. During the final arm, 200 mL/min of air was added to the vent blood as it entered the integral cardiotomy, to more closely simulate vent return during cardiopulmonary bypass. All GME activity in the oxygenator/filter combinations was examined using the Hatteland CMD20 Microemboli Counter. Placement of the Hatteland probes was 4 in after the hard shell reservoir outlet (PRO) and 12 in after the arterial filter (PAF). When vent blood flow was turned on, there was a significant increase in the PRO microemboli activity detected in all reservoirs. In the PAF position, three of the oxygenator/filter combinations were able to remove 98-99% of the GME, one removed 84.3%, and another removed only 55.5% of the GMEs coming out of the oxygenator's reservoir. All oxygenators were found to have a dramatic increase in reservoir GME activity when the vent was turned on. Depending on the oxygenator/filter combination, vent return into the oxygenator's integral cardiotomy resulted in the presence of significant amounts of GMEs after the arterial filter.

Entities:  

Mesh:

Year:  2009        PMID: 19361028      PMCID: PMC4680219     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  31 in total

1.  Investigation on the ability of an ultrasound bubble detector to deliver size measurements of gaseous bubbles in fluid lines by using a glass bead model.

Authors:  S Eitschberger; A Henseler; B Krasenbrink; B Oedekoven; K Mottaghy
Journal:  ASAIO J       Date:  2001 Jan-Feb       Impact factor: 2.872

2.  The dynamic bubble trap reduces microbubbles in extracorporeal circulation and high intensity transient signals in the middle cerebral artery: a case report.

Authors:  Mathias Perthel; Samer Kseibi; Andreas Bendisch; Joachim Laas
Journal:  Perfusion       Date:  2003-09       Impact factor: 1.972

3.  Significant safety advantages gained with an improved pressure-regulated blood pump.

Authors:  J P Montoya; S I Merz; R H Bartlett
Journal:  J Extra Corpor Technol       Date:  1996-06

4.  Gaseous microemboli and the influence of microporous membrane oxygenators.

Authors:  Heinz-H Weitkemper; Bernd Oppermann; Andreas Spilker; Hermann-J Knobl; Reiner Körfer
Journal:  J Extra Corpor Technol       Date:  2005-09

5.  Effect of closed minimized cardiopulmonary bypass on cerebral tissue oxygenation and microembolization.

Authors:  A Liebold; A Khosravi; B Westphal; C Skrabal; Y H Choi; C Stamm; A Kaminski; A Alms; T Birken; D Zurakowski; G Steinhoff
Journal:  J Thorac Cardiovasc Surg       Date:  2006-01-18       Impact factor: 5.209

6.  Bubble generation and venous air filtration by hard-shell venous reservoirs: a comparative study.

Authors:  S J Mitchell; T Willcox; D F Gorman
Journal:  Perfusion       Date:  1997-09       Impact factor: 1.972

7.  Impact of embolization during coronary artery bypass grafting on outcome and length of stay.

Authors:  D Barbut; Y W Lo; J P Gold; R R Trifiletti; F S Yao; D N Hager; R B Hinton; O W Isom
Journal:  Ann Thorac Surg       Date:  1997-04       Impact factor: 4.330

8.  Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypass.

Authors:  Rosendo A Rodriguez; Kathryn A Williams; Andrei Babaev; Fraser Rubens; Howard J Nathan
Journal:  Perfusion       Date:  2005-01       Impact factor: 1.972

9.  Cerebral emboli detected during bypass surgery are associated with clamp removal.

Authors:  D Barbut; R B Hinton; T P Szatrowski; G S Hartman; M Bruefach; P Williams-Russo; M E Charlson; J P Gold
Journal:  Stroke       Date:  1994-12       Impact factor: 7.914

10.  Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation.

Authors:  Gerard J Myers
Journal:  J Extra Corpor Technol       Date:  2007-09
View more
  13 in total

1.  Microbubble generation and transmission of medtronic's affinity hardshell venous reservoir and collapsible venous reservoir bag: an in-vitro comparison.

Authors:  Kieron C Potger; Darryl McMillan; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2011-09

2.  In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.

Authors:  Saifei Liu; Richard F Newland; Phillip J Tully; Sigrid C Tuble; Robert A Baker
Journal:  J Extra Corpor Technol       Date:  2011-09

3.  Evidence-based used, yet still controversial: the arterial filter.

Authors:  Filip De Somer
Journal:  J Extra Corpor Technol       Date:  2012-03

4.  Blood temperature management and gaseous microemboli creation: an in-vitro analysis.

Authors:  Joseph Sleep; Ingrid Syhre; Ed Evans
Journal:  J Extra Corpor Technol       Date:  2010-09

5.  Is the air handling capability of the quadrox D pump dependent within an ECMO circuit? An in vitro study.

Authors:  Martin C Gill; Hayden Dando; Dittmer John
Journal:  J Extra Corpor Technol       Date:  2010-09

6.  Sequential Blood Filtration for Extracorporeal Circulation: Initial Results from a Proof-of-Concept Prototype.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2014-09

7.  The effects of pressure on gases in solution: possible insights to improve microbubble filtration for extracorporeal circulation.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2013-06

8.  Microbubble transmission during cardiotomy infusion of a hardshell venous reservoir with integrated cardiotomy versus a softshell venous reservoir with separated cardiotomy: an in vitro comparison.

Authors:  Kieron C Potger; Darryl McMillan; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2013-06

9.  Oxygenator safety evaluation: a focus on connection grip strength and arterial temperature measurement accuracy.

Authors:  Richard F Newland; Robert A Baker; Andrew J Sanderson; Sigrid C Tuble; Phil J Tully
Journal:  J Extra Corpor Technol       Date:  2012-06

10.  Arterial Limb Microemboli during Cardiopulmonary Bypass: Observations from a Congenital Cardiac Surgery Practice.

Authors:  Gregory S Matte; Kevin R Connor; Hua Liu; James A DiNardo; David Faraoni; Frank Pigula
Journal:  J Extra Corpor Technol       Date:  2016-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.