Literature DB >> 23930376

Microbubble transmission during cardiotomy infusion of a hardshell venous reservoir with integrated cardiotomy versus a softshell venous reservoir with separated cardiotomy: an in vitro comparison.

Kieron C Potger1, Darryl McMillan, Mark Ambrose.   

Abstract

An important mechanism for postoperative cognitive impairment after cardiac surgery using cardiopulmonary bypass (CPB) is microemboli. One component of the CPB circuit-the cardiotomy-is a major source of gaseous microemboli because it aspirates significant volumes of air with blood from the operative field and intracardiac chambers. Cardiotomies are either integrated within an open hardshell venous reservoir (IC-HSVR) or are a separate canister attached to a softshell collapsible venous reservoir bag (SC-SSVR). The purpose of this study was to compare the Medtronic IC-HSVR (Affinity NT CVR) with Medtronic's SC-SSVR (CB 1351, CBMVR 1600) in terms of relative microbubble transmission during cardiotomy infusion. A recirculating in vitro circuit primed with blood was used to compare the two cardiotomy-reservoir systems with the venous reservoir in the SC-SSVR further assessed in a fully closed or partially open state (SC-SSVR-closed; SC-SSVR-open). Microbubbles were detected using a GAMPT BC100 Doppler system in the outflow line of the venous reservoir. Measurements were taken before (baseline) and after aerated prime was pumped into the cardiotomy while altering pump flow rates (3 L/min; 5 L/min) and reservoir prime volumes (400 mL; 900 mL). Infusing cardiotomy blood into the venous reservoir was associated with an increase in microbubbles and bubble volume transmitted by both cardiotomy-reservoir systems with the magnitude rising with reduced prime volumes. The effect was markedly greater with the IC-HSVR. The IC-HSVR also transmitted larger bubbles, particularly with reduced prime volumes. There was no significant difference in microbubble transmission seen between the SC-SSVR-closed and SC-SSVR-open. The SC-SSVR transmits fewer microbubbles than the IC-HSVR during cardiotomy infusion and should be considered as the preferential system. Because both cardiotomy-reservoir systems transmitted microbubbles during cardiotomy infusion, particularly at the lower venous reservoir volume, it is important to use strategies to minimize cardiotomy microbubble infusion.

Entities:  

Mesh:

Year:  2013        PMID: 23930376      PMCID: PMC4557584     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  26 in total

Review 1.  Microbubbles: pathophysiology and clinical implications.

Authors:  Michal Barak; Yeshayahu Katz
Journal:  Chest       Date:  2005-10       Impact factor: 9.410

2.  Australian and New Zealand perfusion survey: equipment and monitoring.

Authors:  Robert A Baker; Timothy W Willcox
Journal:  J Extra Corpor Technol       Date:  2006-09

Review 3.  Stroke and encephalopathy after cardiac surgery: an update.

Authors:  Guy M McKhann; Maura A Grega; Louis M Borowicz; William A Baumgartner; Ola A Selnes
Journal:  Stroke       Date:  2005-12-22       Impact factor: 7.914

4.  Estimate of the maximum absorption rate of microscopic arterial air emboli after entry into the arterial circulation during cardiac surgery.

Authors:  F Dexter; B J Hindman; J S Marshall
Journal:  Perfusion       Date:  1996-11       Impact factor: 1.972

5.  Bubble generation and venous air filtration by hard-shell venous reservoirs: a comparative study.

Authors:  S J Mitchell; T Willcox; D F Gorman
Journal:  Perfusion       Date:  1997-09       Impact factor: 1.972

6.  Ultrasonic identification of sources of gaseous microemboli during open heart surgery.

Authors:  E G Gallagher; D T Pearson
Journal:  Thorax       Date:  1973-05       Impact factor: 9.139

7.  An ultrasonic analysis of the comparative efficiency of various cardiotomy reservoirs and micropore blood filters.

Authors:  D T Pearson; B G Watson; P S Waterhouse
Journal:  Thorax       Date:  1978-06       Impact factor: 9.139

Review 8.  Neurologic injury associated with CABG surgery: outcomes, mechanisms, and opportunities for improvement.

Authors:  Donald S Likosky; Robert M Roth; Andrew J Saykin; Clifford J Eskey; Cathy S Ross; Gerald T O'Connor
Journal:  Heart Surg Forum       Date:  2004       Impact factor: 0.676

9.  Carbon dioxide field flooding minimizes residual intracardiac air after open heart operations.

Authors:  W R Webb; L H Harrison; F R Helmcke; A Camino-Lopez; N A Munfakh; H A Heck; P V Moulder
Journal:  Ann Thorac Surg       Date:  1997-11       Impact factor: 4.330

10.  Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypass.

Authors:  Rosendo A Rodriguez; Kathryn A Williams; Andrei Babaev; Fraser Rubens; Howard J Nathan
Journal:  Perfusion       Date:  2005-01       Impact factor: 1.972

View more
  2 in total

1.  Elimination of gaseous microemboli from cardiopulmonary bypass using hypobaric oxygenation.

Authors:  Keith E Gipson; David J Rosinski; Robert B Schonberger; Cathryn Kubera; Eapen S Mathew; Frank Nichols; William Dyckman; Francois Courtin; Bradford Sherburne; Angelique F Bordey; Jeffrey B Gross
Journal:  Ann Thorac Surg       Date:  2013-11-06       Impact factor: 4.330

2.  Optical verification and in-vitro characterization of two commercially available acoustic bubble counters for cardiopulmonary bypass systems.

Authors:  Tim Segers; Marco C Stehouwer; Filip M J J de Somer; Bastian A de Mol; Michel Versluis
Journal:  Perfusion       Date:  2017-08-02       Impact factor: 1.972

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.