Literature DB >> 17972455

Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation.

Gerard J Myers1.   

Abstract

The detection and prevention of gaseous microemboli (GMEs) during cardiopulmonary bypass has generated considerable interest within the cardiac surgical community. There have been several landmark papers that have used transcranial Doppler devices during cardiopulmonary bypass to detect gaseous microemboli activity in the patients' middle cerebral artery during perfusionist interventions. To determine if this source of emboli could be prevented, a shunt was developed between the oxygenator's sampling manifold and the oxygenator's venous line. This shunt bypassed the venous line and emptied into the oxygenator's integral cardiotomy. An in vitro experiment was performed using three open system oxygenators (Sorin Synthesis, Sorin PrimeOx2, and Terumo Capiox SX25) to compare post-arterial filter emboli detection using the Hatteland CMD20 Microbubble Detector under tightly controlled conditions. After injection of air through the sampling manifold, the PrimeOx2 and the Synthesis oxygenators had statistically significant fewer GMEs with the shunt used than when the shunt was not used. Using a shunt in the sampling manifold during perfusionist interventions will dramatically reduce or eliminate gaseous microemboli transmission to the patient during bypass with both the PrimeOx2 and Synthesis oxygenators. However, results indicate that further study of GME handling with all oxygenator's integral cardiotomies is warranted.

Entities:  

Mesh:

Year:  2007        PMID: 17972455      PMCID: PMC4680731     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  14 in total

1.  Microvascular rheology of Definity microbubbles after intra-arterial and intravenous administration.

Authors:  Jonathan R Lindner; Ji Song; Ananda R Jayaweera; Jiri Sklenar; Sanjiv Kaul
Journal:  J Am Soc Echocardiogr       Date:  2002-05       Impact factor: 5.251

2.  Neuropsychologic impairment after coronary bypass surgery: effect of gaseous microemboli during perfusionist interventions.

Authors:  M A Borger; C M Peniston; R D Weisel; M Vasiliou; R E Green; C M Feindel
Journal:  J Thorac Cardiovasc Surg       Date:  2001-04       Impact factor: 5.209

3.  Deairing of the venous drainage in standard extracorporeal circulation results in a profound reduction of arterial micro bubbles.

Authors:  U A Stock; T Müller; R Bienek; H Krause; M Hartrumpf; J Albes
Journal:  Thorac Cardiovasc Surg       Date:  2006-02       Impact factor: 1.827

4.  Use of a large bore syringe creates significantly fewer high intensity transient signals (HITS) into a cardiopulmonary bypass system than a small bore syringe.

Authors:  James L Rudolph; Daniel Tilahun; Patrick R Treanor; Val E Pochay; Meetali A Mahendrakar; Praveen Sagar; Viken L Babikian
Journal:  Perfusion       Date:  2006-01       Impact factor: 1.972

Review 5.  Cerebral emboli and cognitive outcome after cardiac surgery.

Authors:  D A Stump; A T Rogers; J W Hammon; S P Newman
Journal:  J Cardiothorac Vasc Anesth       Date:  1996-01       Impact factor: 2.628

6.  Bubble generation and venous air filtration by hard-shell venous reservoirs: a comparative study.

Authors:  S J Mitchell; T Willcox; D F Gorman
Journal:  Perfusion       Date:  1997-09       Impact factor: 1.972

7.  The effect of arterial filtration on reduction of gaseous microemboli in the middle cerebral artery during cardiopulmonary bypass.

Authors:  T S Padayachee; S Parsons; R Theobold; R G Gosling; P B Deverall
Journal:  Ann Thorac Surg       Date:  1988-06       Impact factor: 4.330

8.  Cerebral microemboli during cardiopulmonary bypass: increased emboli during perfusionist interventions.

Authors:  R L Taylor; M A Borger; R D Weisel; L Fedorko; C M Feindel
Journal:  Ann Thorac Surg       Date:  1999-07       Impact factor: 4.330

9.  Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypass.

Authors:  Rosendo A Rodriguez; Kathryn A Williams; Andrei Babaev; Fraser Rubens; Howard J Nathan
Journal:  Perfusion       Date:  2005-01       Impact factor: 1.972

10.  Microemboli during coronary artery bypass grafting. Genesis and effect on outcome.

Authors:  R E Clark; J Brillman; D A Davis; M R Lovell; T R Price; G J Magovern
Journal:  J Thorac Cardiovasc Surg       Date:  1995-02       Impact factor: 5.209

View more
  7 in total

1.  In-vitro quantification of gaseous microemboli in two extracorporeal life support circuits.

Authors:  Jeffrey Burnside; Daniel Gomez; Thomas J Preston; Vincent F Olshove; Alistair Phillips
Journal:  J Extra Corpor Technol       Date:  2011-09

2.  Evidence-based used, yet still controversial: the arterial filter.

Authors:  Filip De Somer
Journal:  J Extra Corpor Technol       Date:  2012-03

3.  Is the air handling capability of the quadrox D pump dependent within an ECMO circuit? An in vitro study.

Authors:  Martin C Gill; Hayden Dando; Dittmer John
Journal:  J Extra Corpor Technol       Date:  2010-09

4.  Microbubble transmission during cardiotomy infusion of a hardshell venous reservoir with integrated cardiotomy versus a softshell venous reservoir with separated cardiotomy: an in vitro comparison.

Authors:  Kieron C Potger; Darryl McMillan; Mark Ambrose
Journal:  J Extra Corpor Technol       Date:  2013-06

5.  Clinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population.

Authors:  Thomas J Preston; Daniel Gomez; Vincent F Olshove; Alistair Phillips; Mark Galantowicz
Journal:  J Extra Corpor Technol       Date:  2009-12

6.  Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study.

Authors:  Gerard J Myers; Cheri Voorhees; Rob Haynes; Bob Eke
Journal:  J Extra Corpor Technol       Date:  2009-03

7.  Neural network-based modeling of the number of microbubbles generated with four circulation factors in cardiopulmonary bypass.

Authors:  Satoshi Miyamoto; Zu Soh; Shigeyuki Okahara; Akira Furui; Taiichi Takasaki; Keijiro Katayama; Shinya Takahashi; Toshio Tsuji
Journal:  Sci Rep       Date:  2021-01-12       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.