Is the air handling capability of the quadrox D pump dependent within an ECMO circuit? An in vitro study.

Martin C Gill1, Hayden Dando, Dittmer John.   

Abstract

The occurrence of gaseous microemboli (GME) within the extracorporeal membrane oxygenation circuit is largely overlooked, as are methods to ameliorate this occurrence. We aimed to determine if the air handling capability of the Quadrox D oxygenator was dependent upon whether it was used in conjunction with a centrifugal or roller pump; and if application of a Pall air eliminating filter (AEF) would prevent circuit air introduction from intravenous infusions. Using a blood primed circuit 1 mL of air was infused pre pump. GME were quantified post pump and post oxygenator using the EDAC Quantifier. Trials were conducted at 1 and 2 L/min flow. To prevent GME recirculation a Capiox SX18 was used in circuit with negative pressure applied to its oxygenator; an EDAC cuvette distal to this device quantified GME recirculation. Following air infusion, 3-5 minute data recordings were carried out for each trial. Separate trials were carried out for centrifugal and roller pumps, and for each flow rate. The process was then repeated following the application of the AEF to the air infusion line. More GME were detected post Quadrox D when the centrifugal pump was used in comparison to the roller pump at 1 L/min (p < .05), and 2 L/min (p = .05). A greater volume of air was detected post Quadrox D when used in conjunction with the centrifugal device at 1 L/min (p < or = .05), and 2 L/min (p < or = .05). Application of the AEF resulted in zero GME detected at any circuit location. The results of this study confirm that a greater total count and volume of GME are detected distal to the Quadrox D when used in conjunction with a Rotaflow centrifugal pump. Application of a Pall AEF to infusion and drug lines can prevent air introduction from this source.

Entities:  

Mesh:

Year:  2010        PMID: 21114223      PMCID: PMC4679960     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  14 in total

1.  Neuromonitoring and neurocognitive outcome in off-pump versus conventional coronary bypass operation.

Authors:  A Diegeler; R Hirsch; F Schneider; L O Schilling; V Falk; T Rauch; F W Mohr
Journal:  Ann Thorac Surg       Date:  2000-04       Impact factor: 4.330

2.  Neuropsychologic impairment after coronary bypass surgery: effect of gaseous microemboli during perfusionist interventions.

Authors:  M A Borger; C M Peniston; R D Weisel; M Vasiliou; R E Green; C M Feindel
Journal:  J Thorac Cardiovasc Surg       Date:  2001-04       Impact factor: 5.209

3.  Reduction of microemboli count in the priming fluid of cardiopulmonary bypass circuits.

Authors:  Frank Merkle; Wolfgang Boettcher; Fritz Schulz; Michael Kopitz; Andreas Koster; Ewald Hennig; Roland Hetzer
Journal:  J Extra Corpor Technol       Date:  2003-06

4.  The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli.

Authors:  Matthew J Norman; Joseph J Sistino; Jeffrey R Acsell
Journal:  J Extra Corpor Technol       Date:  2004-12

5.  Gaseous microemboli and hyperoxia.

Authors:  Gary Grist
Journal:  J Extra Corpor Technol       Date:  2006-12

6.  Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass?

Authors:  Timothy J Jones; Dwight D Deal; Jason C Vernon; Noel Blackburn; David A Stump
Journal:  Ann Thorac Surg       Date:  2002-12       Impact factor: 4.330

7.  Cerebral microemboli during cardiopulmonary bypass: increased emboli during perfusionist interventions.

Authors:  R L Taylor; M A Borger; R D Weisel; L Fedorko; C M Feindel
Journal:  Ann Thorac Surg       Date:  1999-07       Impact factor: 4.330

8.  Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children.

Authors:  Khin N Win; Shigang Wang; Akif Undar
Journal:  ASAIO J       Date:  2008 Sep-Oct       Impact factor: 2.872

9.  Arterial line filters ranked for gaseous micro-emboli separation performance: an in vitro study.

Authors:  Jeffrey B Riley
Journal:  J Extra Corpor Technol       Date:  2008-03

10.  Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation.

Authors:  Gerard J Myers
Journal:  J Extra Corpor Technol       Date:  2007-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.