Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Maiken Stilling1, Kjeld Anton Nielsen, Kjeld Søballe, Ole Rahbek.   

Abstract

UNLABELLED: Ceramic femoral heads were developed to reduce the wear of conventional ultrahigh-molecular-weight polyethylene (UHMWPE) bearing surfaces in THA. We compared the wear rates of PE acetabular components bearing against femoral heads of zirconia (Zr) or cobalt-chromium (CoCr) in young patients. One surgeon inserted CoCr femoral heads in all 33 patients (33 hips) having THA for primary osteoarthritis from 1996 to 1997 and then Zr femoral heads in all 34 patients (36 hips) from 1998 to 1999. The mean age of the entire cohort was 52.5 years (range, 29-64 years). The shells were solid and hydroxyapatite (HA) -coated, liners were argon-sterilized UHMWPE, and head size was 28 mm. The minimum clinical followup was 56 months (mean, 65 months; range, 56-77 months); minimum 5-year radiographs were available for 62 of the 68 patients. Wear analysis of digitized anteroposterior (AP) radiographs was performed with a computerized method. Demographic data were comparable in the two groups. Mean femoral head penetration rate was similar in the two types of heads (CoCr: 0.25 mm/year; range, 0.21-0.33 mm/year; Zr: 0.23 mm/year; range, 0.20-0.29 mm/year), as was mean linear wear (CoCr: 1.22 mm; range, 0.28-3.78 mm; Zr: 1.11 mm; range, 0.15-2.05 mm). There were no revisions. These data support skepticism regarding the clinical wear advantage of Zr compared with CoCr femoral heads. The explanation for the clinical similarity of wear, despite the theoretical advantages of ceramic heads, needs further investigation. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19326182      PMCID: PMC2745450          DOI: 10.1007/s11999-009-0799-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  34 in total

1.  Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty.

Authors:  Matthew B Collier; Matthew J Kraay; Clare M Rimnac; Victor M Goldberg
Journal:  J Bone Joint Surg Am       Date:  2003-12       Impact factor: 5.284

2.  Femoral head technologies to reduce polyethylene wear in total hip arthroplasty.

Authors:  J M Cuckler; J Bearcroft; C M Asgian
Journal:  Clin Orthop Relat Res       Date:  1995-08       Impact factor: 4.176

3.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

4.  Effect of femoral head size on wear of the polyethylene acetabular component.

Authors:  J Livermore; D Ilstrup; B Morrey
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

5.  Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique.

Authors:  P A Devane; R B Bourne; C H Rorabeck; R M Hardie; J G Horne
Journal:  Clin Orthop Relat Res       Date:  1995-10       Impact factor: 4.176

6.  Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints.

Authors:  B Derbyshire; J Fisher; D Dowson; C Hardaker; K Brummitt
Journal:  Med Eng Phys       Date:  1994-05       Impact factor: 2.242

7.  Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.

Authors:  T P Schmalzried; M Jasty; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1992-07       Impact factor: 5.284

8.  The John Charnley Award. Wear is a function of use, not time.

Authors:  T P Schmalzried; E F Shepherd; F J Dorey; W O Jackson; M dela Rosa; F Fa'vae; H A McKellop; C D McClung; J Martell; J R Moreland; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2000-12       Impact factor: 4.176

Review 9.  Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear.

Authors:  I C Clarke; A Gustafson
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

10.  Similar wear in total hip arthroplasties with metallic or zirconia femoral heads.

Authors:  Randy M Cohn; Alejandro González Della Valle; Margaret Peterson; Charles N Cornell
Journal:  HSS J       Date:  2008-07-15
View more
  9 in total

1.  Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register.

Authors:  Thomas Kadar; Eva Dybvik; Geir Hallan; Ove Furnes; Leif Ivar Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Letter to the editor: Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Marcel E Roy; Leo A Whiteside
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

3.  Long-term outcomes of total hip arthroplasty in patients younger than 55 years: a systematic review of the contemporary literature

Authors:  Xin Yu Mei; Ying Jia Gong; Oleg Safir; Allan Gross; Paul Kuzyk
Journal:  Can J Surg       Date:  2019-08-01       Impact factor: 2.089

4.  Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.

Authors:  Marcel E Roy; Leo A Whiteside; Mark E Magill; Brian J Katerberg
Journal:  Clin Orthop Relat Res       Date:  2011-02-11       Impact factor: 4.176

5.  The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty. A study of validity and reliability.

Authors:  Maiken Stilling; Kristian Larsen; Niels T Andersen; Kjeld Søballe; Søren Kold; Ole Rahbek
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

Review 6.  Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty.

Authors:  Anton H Hosman; Henny C van der Mei; Sjoerd K Bulstra; Henk J Busscher; Danielle Neut
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

7.  No Difference in Conventional Polyethylene Wear Between Yttria-stabilized Zirconia and Cobalt-chromium-molybdenum Femoral Heads at 10 Years.

Authors:  Todd A Morrison; Rebecca D Moore; Jia Meng; Clare M Rimnac; Matthew J Kraay
Journal:  HSS J       Date:  2017-10-13

8.  Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear: A phantom study.

Authors:  M Stilling; S Kold; S de Raedt; N T Andersen; O Rahbek; K Søballe
Journal:  Bone Joint Res       Date:  2012-08-01       Impact factor: 5.853

9.  In vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up.

Authors:  Masahiro Hasegawa; Akihiro Sudo
Journal:  BMC Musculoskelet Disord       Date:  2013-05-01       Impact factor: 2.362

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.