Literature DB >> 29398997

No Difference in Conventional Polyethylene Wear Between Yttria-stabilized Zirconia and Cobalt-chromium-molybdenum Femoral Heads at 10 Years.

Todd A Morrison1, Rebecca D Moore1, Jia Meng2, Clare M Rimnac3, Matthew J Kraay1.   

Abstract

BACKGROUND: Concerns have arisen regarding deterioration of wear properties of yttria-stabilized zirconia (YSZ) femoral head on conventional polyethylene (PE) bearings due to YSZ phase transformation. QUESTIONS/PURPOSES: The purpose of this study was to determine if there is a difference in long-term PE wear properties between YSZ and cobalt-chromium-molybdenum (Co-Cr-Mo) femoral heads.
METHODS: Ten-year radiographic wear assessment was performed on a cohort of patients enrolled in a prospective randomized clinical trial comparing total hip arthroplasty with YSZ or Co-Cr-Mo femoral heads on conventional, non-cross-linked PE.
RESULTS: PE linear wear, annualized wear, and steady-state wear rates remained low and similar between groups. No cases of osteolysis were observed.
CONCLUSIONS: Measured conventional PE wear was similar between YSZ and Co-Cr-Mo femoral heads with the steady-state wear rates for both remaining below the generally accepted threshold at which osteolysis typically occurs. Whether clinically relevant phase transformation with YSZ femoral heads occurs is uncertain; however, the use of YSZ femoral heads in this study was not associated with increased PE wear, osteolysis, or deterioration of wear properties.

Entities:  

Keywords:  ceramic; hip; polyethylene; wear analysis; zirconia

Year:  2017        PMID: 29398997      PMCID: PMC5786591          DOI: 10.1007/s11420-017-9579-z

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  21 in total

1.  Reassessment of computerized wear measurement for total hip arthroplasty with correction for projectional image distortion: a brief follow-up report.

Authors:  Matthew J Kraay; Rebecca D Moore; John M Martell; Clare M Rimnac
Journal:  J Bone Joint Surg Am       Date:  2010-08-04       Impact factor: 5.284

2.  Revision of a failed cemented total hip prosthesis with insertion of an acetabular component without cement and a femoral component with cement. A five to eight-year follow-up study.

Authors:  K L Weber; J J Callaghan; D D Goetz; R C Johnston
Journal:  J Bone Joint Surg Am       Date:  1996-07       Impact factor: 5.284

Review 3.  Manufacturers affect clinical results of THA with zirconia heads: a systematic review.

Authors:  Hiroyuki Yoshitomi; Satoru Shikata; Hiromu Ito; Takeo Nakayama; Takashi Nakamura
Journal:  Clin Orthop Relat Res       Date:  2009-01-31       Impact factor: 4.176

4.  Tribological and material analyses of retrieved alumina and zirconia ceramic heads correlated with polyethylene wear after total hip replacement.

Authors:  Y-H Kim; J-S Kim
Journal:  J Bone Joint Surg Br       Date:  2008-06

5.  The determination of linear and angular penetration of the femoral head into the acetabular component as an assessment of wear in total hip replacement: a comparison of four computer-assisted methods.

Authors:  C H Geerdink; B Grimm; W Vencken; I C Heyligers; A J Tonino
Journal:  J Bone Joint Surg Br       Date:  2008-07

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  Zirconia femoral head fractures: a clinical and retrieval analysis.

Authors:  John L Masonis; Robert B Bourne; Michael D Ries; Richard W McCalden; Abraham Salehi; David C Kelman
Journal:  J Arthroplasty       Date:  2004-10       Impact factor: 4.757

8.  Similar wear in total hip arthroplasties with metallic or zirconia femoral heads.

Authors:  Randy M Cohn; Alejandro González Della Valle; Margaret Peterson; Charles N Cornell
Journal:  HSS J       Date:  2008-07-15

Review 9.  Patient factors and wear in total hip arthroplasty.

Authors:  Thomas P Schmalzried; Olga L Huk
Journal:  Clin Orthop Relat Res       Date:  2004-01       Impact factor: 4.176

10.  Retrieval analysis of new-generation yttria-stabilized zirconia femoral heads after total hip arthroplasty.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Tadami Matsumoto
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.