Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints.

B Derbyshire1, J Fisher, D Dowson, C Hardaker, K Brummitt.   

Abstract

The wear of ultra high molecular weight polyethylene (UHMWPE) when sliding against zirconia ceramic and stainless steel counterfaces has been compared in a pin-on-plate reciprocator and in a hip joint simulator. A lower wear factor was found for the UHMWPE when sliding on the zirconia ceramic counterfaces in the pin-on-plate tests. In the hip joint simulator test, the acetabular cups articulating on zirconia heads showed consistently lower volume changes than the cups articulating on stainless steel heads. The higher volume changes found with the stainless steel heads were associated with an increased roughness of the femoral heads during the tests. This roughening was caused by the adherence of a rough polymer transfer film.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8061909     DOI: 10.1016/1350-4533(94)90042-6

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Fabrication and evaluation of SixNy coatings for total joint replacements.

Authors:  J Olofsson; M Pettersson; N Teuscher; A Heilmann; K Larsson; K Grandfield; C Persson; S Jacobson; H Engqvist
Journal:  J Mater Sci Mater Med       Date:  2012-06-12       Impact factor: 3.896

2.  Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study.

Authors:  Jean Langlois; Samer El Hage; Faouzi Madi; Jean-Pierre Courpied; Marcel Kerboull; Moussa Hamadouche
Journal:  Int Orthop       Date:  2013-01-31       Impact factor: 3.075

3.  Surface crystalline phases and nanoindentation hardness of explanted zirconia femoral heads.

Authors:  Shane A Catledge; Monique Cook; Yogesh K Vohra; Erick M Santos; Michelle D McClenny; K David Moore
Journal:  J Mater Sci Mater Med       Date:  2003-10       Impact factor: 3.896

4.  Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Maiken Stilling; Kjeld Anton Nielsen; Kjeld Søballe; Ole Rahbek
Journal:  Clin Orthop Relat Res       Date:  2009-03-27       Impact factor: 4.176

5.  Evaluation of silicon nitride as a wear resistant and resorbable alternative for total hip joint replacement.

Authors:  Johanna Olofsson; T Mikael Grehk; Torun Berlind; Cecilia Persson; Staffan Jacobson; Håkan Engqvist
Journal:  Biomatter       Date:  2012 Apr-Jun
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.