Literature DB >> 22644422

Head material influences survival of a cemented total hip prosthesis in the Norwegian Arthroplasty Register.

Thomas Kadar1, Eva Dybvik, Geir Hallan, Ove Furnes, Leif Ivar Havelin.   

Abstract

BACKGROUND: High prosthesis survival is reported for total hip prostheses with metal and alumina heads, but direct comparisons of a single prosthesis design with one of two different head materials has seldom been studied. Prostheses with zirconia heads are less commonly used than metal and alumina heads, and the few reports suggest variable results with zirconia heads. QUESTIONS/PURPOSES: We therefore asked: (1) Would metal heads provide better survival of a cemented total hip arthroplasty (THA) than alumina heads? (2) Would metal heads provide better survival of a cemented THA than zirconia heads?
METHODS: We searched in the Norwegian Arthroplasty Register for cemented primary THA cup/stem combinations that simultaneously had been used with different head materials. The only THA that fulfilled these inclusion criteria was the cemented Reflection All-Poly/Spectron EF (cup/stem) that had during 2001 to 2006 been used both with alumina (n = 448) and cobalt-chromium (n = 5229) heads; that implant had also been used with zirconia (n = 275) and cobalt-chromium heads (n = 3195) during 1997 to 2003, and we included patients with this THA from these two time intervals in the study. All cups were conventional polyethylene. We estimated prosthesis survival and relative revision risks adjusting for age, sex, and diagnosis. The followup in the two study materials was until December 2010.
RESULTS: The survival at 8 years of the Spectron EF/Reflection THAs, inserted with alumina and cobalt-chromium heads during 2001 to 2006, was 92.3% and 94.0%, respectively. The Reflection/Spectron EF THA had inferior survival with zirconia heads compared with cobalt-chromium heads (relative risk, 1.7). At 12 years, the survival rate was 88.1% with cobalt-chromium heads and 74.8% with zirconia heads.
CONCLUSIONS: Alumina femoral heads provided no advantage over cobalt-chromium heads on midterm prosthesis survival. THAs with zirconia heads had inferior survival. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22644422      PMCID: PMC3462857          DOI: 10.1007/s11999-012-2396-2

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  30 in total

1.  Phase transformation of a zirconia ceramic head after total hip arthroplasty.

Authors:  K Haraguchi; N Sugano; T Nishii; H Miki; K Oka; H Yoshikawa
Journal:  J Bone Joint Surg Br       Date:  2001-09

Review 2.  The design features of cemented femoral hip implants.

Authors:  T Scheerlinck; P-P Casteleyn
Journal:  J Bone Joint Surg Br       Date:  2006-11

Review 3.  Manufacturers affect clinical results of THA with zirconia heads: a systematic review.

Authors:  Hiroyuki Yoshitomi; Satoru Shikata; Hiromu Ito; Takeo Nakayama; Takashi Nakamura
Journal:  Clin Orthop Relat Res       Date:  2009-01-31       Impact factor: 4.176

4.  Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head.

Authors:  H Minakawa; M H Stone; B M Wroblewski; J G Lancaster; E Ingham; J Fisher
Journal:  J Bone Joint Surg Br       Date:  1998-09

5.  Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: a ten-year follow-up with radiostereometry.

Authors:  Jon Dahl; Per Söderlund; Bo Nivbrant; Lars Nordsletten; Stephan M Röhrl
Journal:  Int Orthop       Date:  2011-08-26       Impact factor: 3.075

6.  The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.

Authors:  Geraint E R Thomas; David J Simpson; Shahid Mehmood; Adrian Taylor; Peter McLardy-Smith; Harinderjit Singh Gill; David W Murray; Siôn Glyn-Jones
Journal:  J Bone Joint Surg Am       Date:  2011-04-20       Impact factor: 5.284

Review 7.  Ceramic femoral head retrieval data.

Authors:  G Willmann
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

8.  Registration completeness in the Norwegian Arthroplasty Register.

Authors:  Birgitte Espehaug; Ove Furnes; Leif I Havelin; Lars B Engesaeter; Stein E Vollset; Ola Kindseth
Journal:  Acta Orthop       Date:  2006-02       Impact factor: 3.717

9.  5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis.

Authors:  Georgios Digas; Johan Kärrholm; Jonas Thanner; Peter Herberts
Journal:  Acta Orthop       Date:  2007-12       Impact factor: 3.717

10.  Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Maiken Stilling; Kjeld Anton Nielsen; Kjeld Søballe; Ole Rahbek
Journal:  Clin Orthop Relat Res       Date:  2009-03-27       Impact factor: 4.176

View more
  5 in total

1.  Charnley-Kerboull total hip arthroplasty combining zirconia on polyethylene. A minimum eight-year follow-up prospective study.

Authors:  Jean Langlois; Samer El Hage; Faouzi Madi; Jean-Pierre Courpied; Marcel Kerboull; Moussa Hamadouche
Journal:  Int Orthop       Date:  2013-01-31       Impact factor: 3.075

2.  Retrieval analysis of new-generation yttria-stabilized zirconia femoral heads after total hip arthroplasty.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Tadami Matsumoto
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-12-31

3.  Influence of implant variations on survival of the Lubinus SP II stem: evaluation of 76,530 hips in the Swedish Arthroplasty Register, 2000-2018.

Authors:  Raed Itayem; Ola Rolfson; Maziar Mohaddes; Johan Kärrholm
Journal:  Acta Orthop       Date:  2022-01-03       Impact factor: 3.717

4.  No Difference in Conventional Polyethylene Wear Between Yttria-stabilized Zirconia and Cobalt-chromium-molybdenum Femoral Heads at 10 Years.

Authors:  Todd A Morrison; Rebecca D Moore; Jia Meng; Clare M Rimnac; Matthew J Kraay
Journal:  HSS J       Date:  2017-10-13

5.  Novel chitosan/diclofenac coatings on medical grade stainless steel for hip replacement applications.

Authors:  Matjaž Finšgar; Amra Perva Uzunalić; Janja Stergar; Lidija Gradišnik; Uroš Maver
Journal:  Sci Rep       Date:  2016-05-24       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.