Similar wear in total hip arthroplasties with metallic or zirconia femoral heads.

Randy M Cohn1, Alejandro González Della Valle, Margaret Peterson, Charles N Cornell.   

Abstract

Ceramic femoral heads have been used in an attempt at reducing polyethylene wear of total hip arthroplasties. Clinical results with zirconia femoral heads have been mixed. This study was undertaken to compare the polyethylene wear and incidence of periprosthetic osteolysis in total hip replacements performed using a 28-mm zirconia versus a 28-mm cobalt chromium femoral head. Thirty-five hips with a 28-mm cobalt chromium head and 68 hips with a 28-mm zirconia head were evaluated after a minimum follow-up of 2 years (average, 4.0 years; range, 2.0 to 9.1 years). A monoblock acetabular component was used in all patients. Polyethylene wear was measured in serial radiographs from 58 of the hips utilizing a computer-assisted vector wear technique. Periacetabular osteolysis developed in three patients (two with a zirconia head and one with a cobalt chromium head). The total wear and the annual wear rate were 0.48 mm and 0.11 mm/year for the cobalt chromium heads and 0.53 mm and 0.14 mm/year for the zirconia heads, respectively. We found no benefit with respect to the rate of polyethylene wear or incidence of osteolysis with the use of zirconia femoral heads.

Entities:  

Year:  2008        PMID: 18815852      PMCID: PMC2553166          DOI: 10.1007/s11420-008-9084-5

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  26 in total

1.  Phase transformation of a zirconia ceramic head after total hip arthroplasty.

Authors:  K Haraguchi; N Sugano; T Nishii; H Miki; K Oka; H Yoshikawa
Journal:  J Bone Joint Surg Br       Date:  2001-09

2.  Assessment of head wear more than ten years after total hip arthroplasty: 22-mm zirconia vs. metal heads.

Authors:  Atsushi Inoue; Koji Asaumi; Hirosuke Endo; Kazuo Fujiwara; Shigeru Mitani; Toshifumi Ozaki
Journal:  Acta Med Okayama       Date:  2006-12       Impact factor: 0.892

3.  Contact damage in an yttria stabilized zirconia: implications.

Authors:  J Zhou; J Mah; P Shrotriya; C Mercer; W O Soboyejo
Journal:  J Mater Sci Mater Med       Date:  2007-01       Impact factor: 3.896

4.  Failures of yttria-stabilised tetragonal zirconia: 52 retrieved ceramic femoral heads of total hip prostheses.

Authors:  M Fernández-Fairén; P Sala; F J Gil
Journal:  Biomed Mater Eng       Date:  2006       Impact factor: 1.300

5.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study.

Authors:  Y H Kim; J S Kim; S H Cho
Journal:  J Bone Joint Surg Br       Date:  2001-07

8.  Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.

Authors:  D H Sochart
Journal:  Clin Orthop Relat Res       Date:  1999-06       Impact factor: 4.176

9.  Zirconia femoral head fractures: a clinical and retrieval analysis.

Authors:  John L Masonis; Robert B Bourne; Michael D Ries; Richard W McCalden; Abraham Salehi; David C Kelman
Journal:  J Arthroplasty       Date:  2004-10       Impact factor: 4.757

10.  Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up.

Authors:  Karl F Orishimo; Alexandra M Claus; Christi J Sychterz; Charles A Engh
Journal:  J Bone Joint Surg Am       Date:  2003-06       Impact factor: 5.284

View more
  5 in total

1.  Case reports: Tantalum debris dispersion during revision of a tibial component for TKA.

Authors:  Jose Miguel Sanchez Marquez; Nicolas Del Sel; Alejandro Leali; Alejandro González Della Valle
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

2.  A review of protein adsorption on bioceramics.

Authors:  Kefeng Wang; Changchun Zhou; Youliang Hong; Xingdong Zhang
Journal:  Interface Focus       Date:  2012-03-22       Impact factor: 3.906

3.  Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.

Authors:  Maiken Stilling; Kjeld Anton Nielsen; Kjeld Søballe; Ole Rahbek
Journal:  Clin Orthop Relat Res       Date:  2009-03-27       Impact factor: 4.176

4.  No Difference in Conventional Polyethylene Wear Between Yttria-stabilized Zirconia and Cobalt-chromium-molybdenum Femoral Heads at 10 Years.

Authors:  Todd A Morrison; Rebecca D Moore; Jia Meng; Clare M Rimnac; Matthew J Kraay
Journal:  HSS J       Date:  2017-10-13

5.  In vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up.

Authors:  Masahiro Hasegawa; Akihiro Sudo
Journal:  BMC Musculoskelet Disord       Date:  2013-05-01       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.