Abstract

Various methods have been used for time-resolved contrast-enhanced magnetic resonance angiography (CE-MRA), many involving view sharing. However, the extent to which the resultant image time series represents the actual dynamic behavior of the contrast bolus is not always clear. Although numerical simulations can be used to estimate performance, an experimental study can allow more realistic characterization. The purpose of this work was to use a computer-controlled motion phantom for study of the temporal fidelity of three-dimensional (3D) time-resolved sequences in depicting a contrast bolus. It is hypothesized that the view order of the acquisition and the selection of views in the reconstruction can affect the positional accuracy and sharpness of the leading edge of the bolus and artifactual signal preceding the edge. Phantom studies were performed using dilute gadolinium-filled vials that were moved along tabletop tracks by a computer-controlled motor. Several view orders were tested using view-sharing and Cartesian sampling. Compactness of measuring the k-space center, consistency of view ordering within each reconstruction frame, and sampling the k-space center near the end of the temporal footprint were shown to be important in accurate portrayal of the leading edge of the bolus. A number of findings were confirmed in an in vivo CE-MRA study. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19319897      PMCID: PMC2918382          DOI: 10.1002/mrm.21993

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  33 in total

1.  Undersampled projection reconstruction applied to MR angiography.

Authors:  D C Peters; F R Korosec; T M Grist; W F Block; J E Holden; K K Vigen; C A Mistretta
Journal:  Magn Reson Med       Date:  2000-01       Impact factor: 4.668

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience.

Authors:  Winfried A Willinek; Jürgen Gieseke; Rudolf Conrad; Holger Strunk; Romhild Hoogeveen; Marcus von Falkenhausen; Ewald Keller; Horst Urbach; Christiane K Kuhl; Hans H Schild
Journal:  Radiology       Date:  2002-11       Impact factor: 11.105

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels.

Authors:  J Du; T J Carroll; H J Wagner; K Vigen; S B Fain; W F Block; F R Korosec; T M Grist; C A Mistretta
Journal:  Magn Reson Med       Date:  2002-09       Impact factor: 4.668

6.  3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA.

Authors:  R P Lim; M Shapiro; E Y Wang; M Law; J S Babb; L E Rueff; J S Jacob; S Kim; R H Carson; T P Mulholland; G Laub; E M Hecht
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-03       Impact factor: 3.825

7.  MR fluoroscopy: technical feasibility.

Authors:  S J Riederer; T Tasciyan; F Farzaneh; J N Lee; R C Wright; R J Herfkens
Journal:  Magn Reson Med       Date:  1988-09       Impact factor: 4.668

8.  The effect of injection rate on time-resolved contrast-enhanced peripheral MRA.

Authors:  T J Carroll; F R Korosec; J S Swan; T F Hany; T M Grist; C A Mistretta
Journal:  J Magn Reson Imaging       Date:  2001-10       Impact factor: 4.813

9.  Time-resolved 3D contrast-enhanced MRA of an extended FOV using continuous table motion.

Authors:  Ananth J Madhuranthakam; David G Kruger; Stephen J Riederer; James F Glockner; Houchun H Hu
Journal:  Magn Reson Med       Date:  2004-03       Impact factor: 4.668

10.  2D SENSE for faster 3D MRI.

Authors:  Markus Weiger; Klaas P Pruessmann; Peter Boesiger
Journal:  MAGMA       Date:  2002-03       Impact factor: 2.533

View more
  15 in total

1.  Time-resolved magnetic resonance angiography: evaluation of intrapulmonary circulation parameters in pulmonary arterial hypertension.

Authors:  Hyun J Jeong; Parmede Vakil; John J Sheehan; Sanjiv J Shah; Michael Cuttica; James C Carr; Timothy J Carroll; Amir Davarpanah
Journal:  J Magn Reson Imaging       Date:  2011-01       Impact factor: 4.813

2.  Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

3.  Prospective comparison of cartesian acquisition with projection-like reconstruction magnetic resonance angiography with computed tomography angiography for evaluation of below-the-knee runoff.

Authors:  Phillip M Young; Petrice M Mostardi; James F Glockner; Terri R Vrtiska; Thanila Macedo; Clifton R Haider; Stephen J Riederer
Journal:  J Vasc Interv Radiol       Date:  2013-03       Impact factor: 3.464

4.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

5.  Novel High Spatiotemporal Resolution Versus Standard-of-Care Dynamic Contrast-Enhanced Breast MRI: Comparison of Image Quality.

Authors:  Courtney K Morrison; Leah C Henze Bancroft; Wendy B DeMartini; James H Holmes; Kang Wang; Ryan J Bosca; Frank R Korosec; Roberta M Strigel
Journal:  Invest Radiol       Date:  2017-04       Impact factor: 6.016

6.  Accelerated noncontrast-enhanced 4-dimensional intracranial MR angiography using golden-angle stack-of-stars trajectory and compressed sensing with magnitude subtraction.

Authors:  Ziwu Zhou; Fei Han; Songlin Yu; Dandan Yu; Stanislas Rapacchi; Hee Kwon Song; Danny J J Wang; Peng Hu; Lirong Yan
Journal:  Magn Reson Med       Date:  2017-05-07       Impact factor: 4.668

7.  Buildup of image quality in view-shared time-resolved 3D CE-MRA.

Authors:  Casey P Johnson; Thomas W Polley; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2012-08-30       Impact factor: 4.668

8.  Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography.

Authors:  Clifton R Haider; James F Glockner; Anthony W Stanson; Stephen J Riederer
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

9.  Use of a computer-controlled motion phantom to investigate the temporal and spatial fidelity of HYPR processing.

Authors:  Lauren Keith; Mahdi Rahimi; James Holmes; Jean Brittain; Frank Korosec
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Pulmonary perfusion MRI using interleaved variable density sampling and HighlY constrained cartesian reconstruction (HYCR).

Authors:  Kang Wang; Mark L Schiebler; Christopher J Francois; A Munoz Del Rio; Ma Daniela Cornejo; Laura C Bell; Frank R Korosec; Jean H Brittain; James H Holmes; Scott K Nagle
Journal:  J Magn Reson Imaging       Date:  2013-01-24       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.