Literature DB >> 19789238

Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography.

Clifton R Haider1, James F Glockner, Anthony W Stanson, Stephen J Riederer.   

Abstract

PURPOSE: To prospectively evaluate the feasibility of performing high-spatial-resolution (1-mm isotropic) time-resolved three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiography of the peripheral vasculature with Cartesian acquisition with projection-reconstruction-like sampling (CAPR) and eightfold accelerated two-dimensional (2D) sensitivity encoding (SENSE).
MATERIALS AND METHODS: All studies were approved by the institutional review board and were HIPAA compliant; written informed consent was obtained from all participants. There were 13 volunteers (mean age, 41.9; range, 27-53 years). The CAPR sequence was adapted to provide 1-mm isotropic spatial resolution and a 5-second frame time. Use of different receiver coil element sizes for those placed on the anterior-to-posterior versus left-to-right sides of the field of view reduced signal-to-noise ratio loss due to acceleration. Results from eight volunteers were rated independently by two radiologists according to prominence of artifact, arterial to venous separation, vessel sharpness, continuity of arterial signal intensity in major arteries (anterior and posterior tibial, peroneal), demarcation of origin of major arteries, and overall diagnostic image quality. MR angiographic results in two patients with peripheral vascular disease were compared with their results at computed tomographic angiography.
RESULTS: The sequence exhibited no image artifact adversely affecting diagnostic image quality. Temporal resolution was evaluated to be sufficient in all cases, even with known rapid arterial to venous transit. The vessels were graded to have excellent sharpness, continuity, and demarcation of the origins of the major arteries. Distal muscular branches and the communicating and perforating arteries were routinely seen. Excellent diagnostic quality rating was given for 15 (94%) of 16 evaluations.
CONCLUSION: The feasibility of performing high-diagnostic-quality time-resolved 3D contrast-enhanced MR angiography of the peripheral vasculature by using CAPR and eightfold accelerated 2D SENSE has been demonstrated.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19789238      PMCID: PMC2817830          DOI: 10.1148/radiol.2533081744

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  47 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Whole-body MR angiography using variable density sampling and dual-injection bolus-chase acquisition.

Authors:  Jiang Du; Frank R Korosec; Yijing Wu; Thomas M Grist; Charles A Mistretta
Journal:  Magn Reson Imaging       Date:  2007-09-10       Impact factor: 2.546

3.  High-resolution magnetic resonance angiography of the lower extremities with a dedicated 36-element matrix coil at 3 Tesla.

Authors:  Harald Kramer; Henrik J Michaely; Volker Matschl; Peter Schmitt; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Invest Radiol       Date:  2007-06       Impact factor: 6.016

4.  3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA.

Authors:  R P Lim; M Shapiro; E Y Wang; M Law; J S Babb; L E Rueff; J S Jacob; S Kim; R H Carson; T P Mulholland; G Laub; E M Hecht
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-03       Impact factor: 3.825

5.  Cerebral arteriovenous malformation: Spetzler-Martin classification at subsecond-temporal-resolution four-dimensional MR angiography compared with that at DSA.

Authors:  Dariusch R Hadizadeh; Marcus von Falkenhausen; Jürgen Gieseke; Bernhard Meyer; Horst Urbach; Romhild Hoogeveen; Hans H Schild; Winfried A Willinek
Journal:  Radiology       Date:  2007-10-19       Impact factor: 11.105

6.  High-spatial-resolution lower extremity MR angiography at 3.0 T: contrast agent dose comparison study.

Authors:  Reza Habibi; Mayil S Krishnam; Derek G Lohan; Fatemeh Barkhordarian; Mehdi Jalili; Roya S Saleh; Stefan G Ruehm; J Paul Finn
Journal:  Radiology       Date:  2008-06-23       Impact factor: 11.105

7.  Controlled experimental study depicting moving objects in view-shared time-resolved 3D MRA.

Authors:  Petrice M Mostardi; Clifton R Haider; Phillip J Rossman; Eric A Borisch; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

8.  3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain.

Authors:  Clifton R Haider; Houchun Harry Hu; Norbert G Campeau; John Huston; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

9.  Magnetic resonance angiography in infrapopliteal arterial disease: prospective comparison of 1.5 and 3 Tesla magnetic resonance imaging.

Authors:  Nicolas Diehm; Ralph Kickuth; Iris Baumgartner; Sudesh K Srivastav; Silvia Gretener; Marc J Husmann; Yves Jaccard; Do Dai Do; Juergen Triller; Harald M Bonel
Journal:  Invest Radiol       Date:  2007-06       Impact factor: 6.016

10.  CE-MRA of the lower extremities using HYPR stack-of-stars.

Authors:  Yan Wu; Frank R Korosec; Charles A Mistretta; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2009-04       Impact factor: 4.813

View more
  23 in total

1.  NonCartesian MR image reconstruction with integrated gradient nonlinearity correction.

Authors:  Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; John Huston; Kevin M Johnson; Paul T Weavers; Erin M Gray; Matt A Bernstein
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

Review 2.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

Review 3.  Sub-Nyquist acquisition and constrained reconstruction in time resolved angiography.

Authors:  Charles A Mistretta
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  Prospective comparison of cartesian acquisition with projection-like reconstruction magnetic resonance angiography with computed tomography angiography for evaluation of below-the-knee runoff.

Authors:  Phillip M Young; Petrice M Mostardi; James F Glockner; Terri R Vrtiska; Thanila Macedo; Clifton R Haider; Stephen J Riederer
Journal:  J Vasc Interv Radiol       Date:  2013-03       Impact factor: 3.464

5.  Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction.

Authors:  Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; Paul T Weavers; John Huston; Erin M Gray; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2015-07-17       Impact factor: 4.668

6.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

7.  Three-station three-dimensional bolus-chase MR angiography with real-time fluoroscopic tracking.

Authors:  Casey P Johnson; Paul T Weavers; Eric A Borisch; Roger C Grimm; Thomas C Hulshizer; Christine C LaPlante; Phillip J Rossman; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Radiology       Date:  2014-03-14       Impact factor: 11.105

8.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

9.  Three-dimensional through-time radial GRAPPA for renal MR angiography.

Authors:  Katherine L Wright; Gregory R Lee; Philipp Ehses; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-21       Impact factor: 4.813

10.  Acceleration apportionment: a method of improved 2D SENSE acceleration applied to 3D contrast-enhanced MR angiography.

Authors:  Paul T Weavers; Eric A Borisch; Casey P Johnson; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.