Literature DB >> 19789236

Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography.

Stephen J Riederer1, Clifton R Haider, Eric A Borisch.   

Abstract

This study was HIPAA compliant and institutional review board approved, and informed consent was obtained from all volunteers. The authors describe a method for generating a time-of-arrival (TOA) map of intravenously administered contrast material, as observed in a time series of three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiograms. The method may enable visualization and interpretation, on one 3D image, of the temporal enhancement patterns that occur in the vasculature. Colorization of TOA values may further aid interpretation. The quality of the results depends not only on the adequacy of the frame rate, spatial resolution, and signal-to-noise ratio of the MR image acquisition method but also on the accuracy and clarity with which the leading edge of the contrast material bolus is depicted. The criteria for optimizing these parameters are described. The TOA mapping technique is demonstrated by using vascular studies of the hands, brain, and lower leg regions. (c) RSNA, 2009.

Mesh:

Substances:

Year:  2009        PMID: 19789236      PMCID: PMC2770111          DOI: 10.1148/radiol.2532082322

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  31 in total

1.  Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography.

Authors:  Ananth J Madhuranthakam; Houchun H Hu; Andrew V Barger; Clifton R Haider; David G Kruger; James F Glockner; John Huston; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

2.  Highly constrained backprojection for time-resolved MRI.

Authors:  C A Mistretta; O Wieben; J Velikina; W Block; J Perry; Y Wu; K Johnson; Y Wu
Journal:  Magn Reson Med       Date:  2006-01       Impact factor: 4.668

3.  Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: application to the renal arteries.

Authors:  A H Wilman; S J Riederer; B F King; J P Debbins; P J Rossman; R L Ehman
Journal:  Radiology       Date:  1997-10       Impact factor: 11.105

4.  3D time-resolved contrast-enhanced MR DSA: advantages and tradeoffs.

Authors:  C A Mistretta; T M Grist; F R Korosec; R Frayne; D C Peters; Y Mazaheri; T J Carrol
Journal:  Magn Reson Med       Date:  1998-10       Impact factor: 4.668

5.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

6.  Time-resolved contrast-enhanced 3D MR angiography.

Authors:  F R Korosec; R Frayne; T M Grist; C A Mistretta
Journal:  Magn Reson Med       Date:  1996-09       Impact factor: 4.668

7.  Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector.

Authors:  J P Earls; N M Rofsky; D R DeCorato; G A Krinsky; J C Weinreb
Journal:  Radiology       Date:  1996-12       Impact factor: 11.105

8.  Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches.

Authors:  M R Prince; D L Narasimham; J C Stanley; T L Chenevert; D M Williams; M V Marx; K J Cho
Journal:  Radiology       Date:  1995-12       Impact factor: 11.105

9.  Cerebral arteriovenous malformation: Spetzler-Martin classification at subsecond-temporal-resolution four-dimensional MR angiography compared with that at DSA.

Authors:  Dariusch R Hadizadeh; Marcus von Falkenhausen; Jürgen Gieseke; Bernhard Meyer; Horst Urbach; Romhild Hoogeveen; Hans H Schild; Winfried A Willinek
Journal:  Radiology       Date:  2007-10-19       Impact factor: 11.105

10.  Time-resolved 3D contrast-enhanced MRA with GRAPPA on a 1.5-T system for imaging of craniocervical vascular disease: initial experience.

Authors:  Stephan Meckel; Ralf Mekle; Christian Taschner; Sven Haller; Klaus Scheffler; Ernst-Wilhelm Radue; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2006-03-11       Impact factor: 2.804

View more
  6 in total

1.  Noncontrast dynamic 3D intracranial MR angiography using pseudo-continuous arterial spin labeling (PCASL) and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; David J Rusinak; Yijing Wu; Kevin M Johnson
Journal:  J Magn Reson Imaging       Date:  2013-10-15       Impact factor: 4.813

2.  Time-of-Arrival Parametric Maps and Virtual Bolus Images Derived From Contrast-Enhanced Time-Resolved Radial Magnetic Resonance Angiography Improve the Display of Brain Arteriovenous Malformation Vascular Anatomy.

Authors:  Tilman Schubert; Yijing Wu; Kevin M Johnson; Oliver Wieben; Jane Maksimovic; Charles Mistretta; Patrick Turski
Journal:  Invest Radiol       Date:  2016-11       Impact factor: 6.016

Review 3.  High temporal and spatial resolution 3D time-resolved contrast-enhanced magnetic resonance angiography of the hands and feet.

Authors:  Clifton R Haider; Stephen J Riederer; Eric A Borisch; James F Glockner; Roger C Grimm; Thomas C Hulshizer; Thanila A Macedo; Petrice M Mostardi; Phillip J Rossman; Terri J Vrtiska; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2011-07       Impact factor: 4.813

4.  High spatial and temporal resolution imaging of the arterial vasculature of the lower extremity with contrast enhanced MR angiography.

Authors:  Petrice M Mostardi; Clifton R Haider; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Clin Anat       Date:  2011-01-12       Impact factor: 2.414

5.  High temporal and spatial resolution imaging of peripheral vascular malformations.

Authors:  Petrice M Mostardi; Phillip M Young; Michael A McKusick; Stephen J Riederer
Journal:  J Magn Reson Imaging       Date:  2012-06-04       Impact factor: 4.813

6.  Pretreatment imaging of peripheral vascular malformations.

Authors:  Joshua B Johnson; Petrice M Cogswell; Michael A McKusick; Larry A Binkovitz; Stephen J Riederer; Phillip M Young
Journal:  J Vasc Diagn       Date:  2014
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.