Literature DB >> 3173063

MR fluoroscopy: technical feasibility.

S J Riederer1, T Tasciyan, F Farzaneh, J N Lee, R C Wright, R J Herfkens.   

Abstract

A method of magnetic resonance image acquisition and reconstruction is described in which high imaging rates and fast reconstruction times are allowed. The acquisition is a modification of the basic FLASH sequence but with a restricted number N of phase encodings. The encodings are applied sequentially, periodically, and continuously. Images are formed by sliding a window of width N encodings along the acquired data and reconstructing an image for each position of the window. In general the acquisition time per image exceeds the time between successive images, and the method thus has a temporal lag. Experimental studies were performed with a dynamic phantom using 48 phase encodings and a TR of 20 ms, for an image acquisition time of about 1 s. The image display rate in the reconstructed sequence was 12.5 images/s, and the image sequence portrayed the motion of the phantom. Additional studies were done with 24 encodings. It is shown how the sliding window technique lends itself to high-speed reconstruction, with each newly acquired echo used to quickly update the image on display. The combination of the acquisition technique described and a hardware implementation of the reconstruction algorithm can result in realtime MR image acquisition and reconstruction.

Mesh:

Year:  1988        PMID: 3173063     DOI: 10.1002/mrm.1910080102

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  78 in total

1.  3D contrast-enhanced MR angiography using fluoroscopic triggering and an elliptical centric view order.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  Int J Card Imaging       Date:  1999-04

2.  Real-time imaging and triggering of 3D contrast-enhanced MR angiograms using MR fluoroscopy.

Authors:  S J Riederer; S B Fain; D G Kruger; R F Busse
Journal:  MAGMA       Date:  1999-08       Impact factor: 2.310

3.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

4.  Catheter-based endomyocardial injection with real-time magnetic resonance imaging.

Authors:  Robert J Lederman; Michael A Guttman; Dana C Peters; Richard B Thompson; Jonathan M Sorger; Alexander J Dick; Venkatesh K Raman; Elliot R McVeigh
Journal:  Circulation       Date:  2002-03-19       Impact factor: 29.690

Review 5.  Future prospects in magnetic resonance imaging.

Authors:  Mark Doyle; Robert W W Biederman
Journal:  Curr Cardiol Rep       Date:  2004-01       Impact factor: 2.931

6.  Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Authors:  Dana C Peters; Robert J Lederman; Alexander J Dick; Venkatesh K Raman; Michael A Guttman; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

Review 7.  Future prospects in cardiac magnetic resonance imaging.

Authors:  Mark Doyle; Robert W W Biederman
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

Review 8.  Neurovascular MRI with dynamic contrast-enhanced subtraction angiography.

Authors:  S C Coley; J M Wild; I D Wilkinson; P D Griffiths
Journal:  Neuroradiology       Date:  2003-09-20       Impact factor: 2.804

9.  Radial sliding-window magnetic resonance angiography (MRA) with highly-constrained projection reconstruction (HYPR).

Authors:  Hyun J Jeong; Ty A Cashen; Michael C Hurley; Christopher Eddleman; Christopher Getch; H Hunt Batjer; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

10.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

View more