Literature DB >> 18768727

3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA.

R P Lim1, M Shapiro, E Y Wang, M Law, J S Babb, L E Rueff, J S Jacob, S Kim, R H Carson, T P Mulholland, G Laub, E M Hecht.   

Abstract

BACKGROUND AND
PURPOSE: Time-resolved MR angiography (MRA) offers the combined advantage of large anatomic coverage and hemodynamic flow information. We applied parallel imaging and time-resolved imaging with stochastic trajectories (TWIST), which uses a spiral trajectory to undersample k-space, to perform time-resolved MRA of the extracranial internal carotid arteries and compare it to time-of-flight (TOF) and high-resolution contrast-enhanced (HR) MRA.
MATERIALS AND METHODS: A retrospective review of 31 patients who underwent carotid MRA at 1.5T using TOF, time-resolved and HR MRA was performed. Images were evaluated for the presence and degree of ICA stenosis, reader confidence, and number of pure arterial frames attained with the TWIST technique.
RESULTS: With a consensus interpretation of all sequences as the reference standard, accuracy for identifying stenosis was 90.3% for TWIST MRA, compared with 96.0% and 88.7% for HR MRA and TOF MRA, respectively. HR MRA was significantly more accurate than the other techniques (P < .05). TWIST MRA yielded datasets with high in-plane spatial resolution and distinct arterial and venous phases. It provided dynamic information not otherwise available. Mean diagnostic confidence was satisfactory or greater for TWIST in all patients.
CONCLUSION: The TWIST technique consistently obtained pure arterial phase images while providing dynamic information. It is rapid, uses a low dose of contrast, and may be useful in specific circumstances, such as in the acute stroke setting. However, it does not yet have spatial resolution comparable with standard contrast-enhanced MRA.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18768727      PMCID: PMC8118944          DOI: 10.3174/ajnr.A1252

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  31 in total

1.  Contrast-enhanced 3D MR angiography of the carotid artery: comparison with conventional digital subtraction angiography.

Authors:  Luca Remonda; Pascal Senn; Alain Barth; Marcel Arnold; Karl-Olof Lövblad; Gerhard Schroth
Journal:  AJNR Am J Neuroradiol       Date:  2002-02       Impact factor: 3.825

2.  Magnetic resonance angiography of the carotid arteries using three different techniques: accuracy compared with intraarterial x-ray angiography and endarterectomy specimens.

Authors:  Claudia Fellner; Werner Lang; Rolf Janka; Ralf Wutke; Werner Bautz; Franz A Fellner
Journal:  J Magn Reson Imaging       Date:  2005-04       Impact factor: 4.813

3.  Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients.

Authors:  Alex Frydrychowicz; Thorsten A Bley; Jan T Winterer; Andreas Harloff; Mathias Langer; Jürgen Hennig; Michael Markl
Journal:  MAGMA       Date:  2006-08-26       Impact factor: 2.310

4.  Gadolinium--a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?

Authors:  Thomas Grobner
Journal:  Nephrol Dial Transplant       Date:  2006-01-23       Impact factor: 5.992

5.  Noise measurement and estimation in MR imaging experiments.

Authors:  Johannes T Heverhagen
Journal:  Radiology       Date:  2007-12       Impact factor: 11.105

6.  Evaluation of carotid artery stenosis with multisection CT and MR imaging: influence of imaging modality and postprocessing.

Authors:  M Lell; C Fellner; U Baum; T Hothorn; R Steiner; W Lang; W Bautz; F A Fellner
Journal:  AJNR Am J Neuroradiol       Date:  2007-01       Impact factor: 3.825

7.  Postoperative assessment of extracranial-intracranial bypass by time-resolved 3D contrast-enhanced MR angiography using parallel imaging.

Authors:  Kazuhiro Tsuchiya; Keita Honya; Akira Fujikawa; Hidekatsu Tateishi; Yoshiaki Shiokawa
Journal:  AJNR Am J Neuroradiol       Date:  2005-10       Impact factor: 3.825

8.  Continuous update with random encoding (CURE): a new strategy for dynamic imaging.

Authors:  T Parrish; X Hu
Journal:  Magn Reson Med       Date:  1995-03       Impact factor: 4.668

9.  Long-term prognosis and effect of endarterectomy in patients with symptomatic severe carotid stenosis and contralateral carotid stenosis or occlusion: results from NASCET. North American Symptomatic Carotid Endarterectomy Trial (NASCET) Group.

Authors:  A P Gasecki; M Eliasziw; G G Ferguson; V Hachinski; H J Barnett
Journal:  J Neurosurg       Date:  1995-11       Impact factor: 5.115

10.  Time-resolved MR angiography: optimal parallel imaging method.

Authors:  J-Y Gauvrit; M Law; J Xu; R Carson; P Sunenshine; Q Chen
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

View more
  58 in total

1.  Bilateral contrast-enhanced MR angiography of the hand: diagnostic image quality of accelerated MRI using echo sharing with interleaved stochastic trajectories (TWIST).

Authors:  Jan Thorsten Winterer; P Blanke; A Schaefer; G Pache; M Langer; M Markl
Journal:  Eur Radiol       Date:  2010-11-18       Impact factor: 5.315

2.  A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings.

Authors:  Luminita A Tudorica; Karen Y Oh; Nicole Roy; Mark D Kettler; Yiyi Chen; Stephanie L Hemmingson; Aneela Afzal; John W Grinstead; Gerhard Laub; Xin Li; Wei Huang
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

3.  Improved quality and diagnostic confidence achieved by use of dose-reduced gadolinium blood-pool agents for time-resolved intracranial MR angiography.

Authors:  S Dehkharghani; J Kang; A M Saindane
Journal:  AJNR Am J Neuroradiol       Date:  2013-08-22       Impact factor: 3.825

Review 4.  [Magnetic resonance imaging of pulmonary perfusion. Technical requirements and diagnostic impact].

Authors:  U I Attenberger; M Ingrisch; K Büsing; M Reiser; S O Schoenberg; C Fink
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

5.  Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

6.  Time-resolved magnetic resonance angiography (MRA) at 3.0 Tesla for evaluation of hemodynamic characteristics of vascular malformations: description of distinct subgroups.

Authors:  Simone Hammer; Wibke Uller; Florentine Manger; Claudia Fellner; Florian Zeman; Walter A Wohlgemuth
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

7.  Simultaneous magnetic resonance angiography and perfusion (MRAP) measurement: initial application in lower extremity skeletal muscle.

Authors:  Katherine L Wright; Nicole Seiberlich; John A Jesberger; Dean A Nakamoto; Raymond F Muzic; Mark A Griswold; Vikas Gulani
Journal:  J Magn Reson Imaging       Date:  2013-02-06       Impact factor: 4.813

8.  Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography.

Authors:  Ting Song; Andrew F Laine; Qun Chen; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Gerhard Laub; Randall Kroeker; Vivian S Lee
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

9.  Acceleration apportionment: a method of improved 2D SENSE acceleration applied to 3D contrast-enhanced MR angiography.

Authors:  Paul T Weavers; Eric A Borisch; Casey P Johnson; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography.

Authors:  Clifton R Haider; James F Glockner; Anthony W Stanson; Stephen J Riederer
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.