In patient dose reconstruction using a cine acquisition for dynamic arc radiation therapy.

Angelo Piermattei1, Andrea Fidanzio, Luigi Azario, Francesca Greco, Alessandra Mameli, Savino Cilla, Luca Grimaldi, Guido D'Onofrio, Boris Giuseppe Augelli, Gerardina Stimato, Diego Gaudino, Sara Ramella, Rolando D'Angelillo, Francesco Cellini, Lucio Trodella.   

Abstract

An amorphous silicon (a-Si) electronic portal imaging device (EPID) was implemented to perform transit in vivo dosimetry for dynamic conformal arc therapy (DCAT). A set of images was acquired for each arc irradiation using the EPID cine acquisition mode, that supplies a frame acquisition rate of one image every 1.66 s, with a monitor unit rate equal to 100 UM/min. In these conditions good signal stability, +/-1% (2SD) evaluated during 3 months, signal reproducibility within +/-0.8% (2SD) and linearity with dose and dose rate within +/-1% (2SD) were obtained. The transit signal, S (t), due to the transmitted radiotherapy beam below a solid phantom, measured by the EPID cine acquisition mode was used to determine, (1) a set of correlation functions, F(w, L), defined as the ratio between S (t) and the dose at half thickness, D (m), measured in solid water phantoms of different thicknesses, w and with square fields of side L, (2) a set of factors, f(d, L), that take into account the different x-ray scatter contribution from the phantom to the S (t) signal as a function of the variation, d, of the air gap between the phantom and the EPID. The reconstruction of the isocenter dose, D (iso), for DCAT was obtained convolving the transit signal values, obtained at different gantry angles, with the respective reconstruction factors determined by a house-made software. The method was applied to a first patient and the results show that the reconstructed D (iso) values can be obtained with an accuracy within +/-5%. In conclusion, it was assessed that an a-Si EPID with the cine acquisition mode is suitable to perform transit in vivo dosimetry for the DCAT therapy.

Entities:  

Mesh:

Year:  2009        PMID: 19221822     DOI: 10.1007/s11517-009-0456-x

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  31 in total

1.  Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58.

Authors:  M G Herman; J M Balter; D A Jaffray; K P McGee; P Munro; S Shalev; M Van Herk; J W Wong
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

2.  An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

Authors:  Ellen E Grein; Richard Lee; Kurt Luchka
Journal:  Med Phys       Date:  2002-10       Impact factor: 4.071

3.  Experimental verification of a portal dose prediction model.

Authors:  W J C van Elmpt; S M J J G Nijsten; B J Mijnheer; A W H Minken
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

4.  American Society for Therapeutic Radiology and Oncology and American College of Radiology practice guideline for the performance of stereotactic body radiation therapy.

Authors:  Louis Potters; Michael Steinberg; Christopher Rose; Robert Timmerman; Samuel Ryu; James M Hevezi; James Welsh; Minesh Mehta; David A Larson; Nora A Janjan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-11-15       Impact factor: 7.038

5.  Calibration of an amorphous-silicon flat panel portal imager for exit-beam dosimetry.

Authors:  Josephine Chen; Cynthia F Chuang; Olivier Morin; Michèle Aubin; Jean Pouliot
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

6.  What degree of accuracy is required and can be achieved in photon and neutron therapy?

Authors:  B J Mijnheer; J J Battermann; A Wambersie
Journal:  Radiother Oncol       Date:  1987-03       Impact factor: 6.280

7.  In vivo dosimetry during conformal radiotherapy: requirements for and findings of a routine procedure.

Authors:  J H Lanson; M Essers; G J Meijer; A W Minken; G J Uiterwaal; B J Mijnheer
Journal:  Radiother Oncol       Date:  1999-07       Impact factor: 6.280

8.  Routine individualised patient dosimetry using electronic portal imaging devices.

Authors:  Sebastiaan M J J G Nijsten; Ben J Mijnheer; André L A J Dekker; Philippe Lambin; André W H Minken
Journal:  Radiother Oncol       Date:  2007-03-26       Impact factor: 6.280

9.  Assessment of the uncertainties in dose delivery of a commercial system for linac-based stereotactic radiosurgery.

Authors:  D Verellen; N Linthout; A Bel; G Soete; D van den Berge; J D' Haens; G Storme
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-05-01       Impact factor: 7.038

10.  In vivo dosimetry during conformal therapy of prostatic cancer.

Authors:  M Essers; J H Lanson; B J Mijnheer
Journal:  Radiother Oncol       Date:  1993-11       Impact factor: 6.280

View more
  5 in total

1.  A simulation technique for computation of the dosimetric effects of setup, organ motion and delineation uncertainties in radiotherapy.

Authors:  Bongile Mzenda; Mir Hosseini-Ashrafi; Antony Palmer; Honghai Liu; David J Brown
Journal:  Med Biol Eng Comput       Date:  2010-04-23       Impact factor: 2.602

2.  A generalized calibration procedure for in vivo transit dosimetry using siemens electronic portal imaging devices.

Authors:  Andrea Fidanzio; Francesca Greco; Laura Gargiulo; Savino Cilla; Domenico Sabatino; Massimo Cappiello; Cinzia Di Felice; Elisabetta Di Castro; Luigi Azario; Mariateresa Russo; Luciano Pompei; Guido D'Onofrio; Angelo Piermattei
Journal:  Med Biol Eng Comput       Date:  2010-11-04       Impact factor: 2.602

3.  Dose-guided radiotherapy for lung tumors.

Authors:  Angelo Piermattei; Andrea Fidanzio; Savino Cilla; Francesca Greco; Luigi Azario; Domenico Sabatino; Mattia Grusio; Mariella Cozzolino; Vincenzo Fusco
Journal:  Med Biol Eng Comput       Date:  2009-12-10       Impact factor: 2.602

4.  Transit dosimetry in dynamic IMRT with an a-Si EPID.

Authors:  Mahsheed Sabet; Pejman Rowshanfarzad; Fred W Menk; Peter B Greer
Journal:  Med Biol Eng Comput       Date:  2014-05-31       Impact factor: 2.602

5.  An investigation of gantry angle data accuracy for cine-mode EPID images acquired during arc IMRT.

Authors:  Peter M McCowan; Daniel W Rickey; Pejman Rowshanfarzad; Peter B Greer; William Ansbacher; Boyd M McCurdy
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.