In vivo dosimetry during conformal therapy of prostatic cancer.

M Essers1, J H Lanson, B J Mijnheer.   

Abstract

In vivo dose measurements were performed during the simultaneous boost technique for prostatic cancer to check the accuracy of dose calculations by a monitor unit calculation program and a three-dimensional planning system. The dose of the large field and the boost field are given simultaneously using customized 10 mm thick Roses-metal blocks in which the boost field is cut out. Following the procedure of the quality assurance protocol for this technique, the dose at the specification point has been determined by in vivo dosimetry. The measured dose was initially too high for 5 out of 16 patients, due to unexpected differences in two beams with the same nominal beam quality and a different density correction for the femoral heads; the monitor unit calculation program was therefore checked and improved. The dose at the specification point was also compared with calculations performed by a CT-based three-dimensional (3-D) planning system. The average deviation of the 3-D planning system from the measurements is 0.1% +/- 1.2%. Entrance, midline and exit dose values in the central axial plane, in a cranial plane and in a plane under the transmission block have also been compared with calculations performed by the 3-D treatment planning system. The measured entrance dose is, on average, 3.4% higher than the calculated dose for the AP beam and up to 5.5% for the lateral beams. Phantom measurements were performed and showed that these differences were not related to patient set-up errors.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8310155     DOI: 10.1016/0167-8140(93)90258-a

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  3 in total

1.  In patient dose reconstruction using a cine acquisition for dynamic arc radiation therapy.

Authors:  Angelo Piermattei; Andrea Fidanzio; Luigi Azario; Francesca Greco; Alessandra Mameli; Savino Cilla; Luca Grimaldi; Guido D'Onofrio; Boris Giuseppe Augelli; Gerardina Stimato; Diego Gaudino; Sara Ramella; Rolando D'Angelillo; Francesco Cellini; Lucio Trodella
Journal:  Med Biol Eng Comput       Date:  2009-02-17       Impact factor: 2.602

2.  Breast in vivo dosimetry by EPID.

Authors:  Andrea Fidanzio; Francesca Greco; Alessandra Mameli; Luigi Azario; Mario Balducci; Maria Antonietta Gambacorta; Vincenzo Frascino; Savino Cilla; Domenico Sabatino; Angelo Piermattei
Journal:  J Appl Clin Med Phys       Date:  2010-09-02       Impact factor: 2.102

3.  Measurement comparison and Monte Carlo analysis for volumetric-modulated arc therapy (VMAT) delivery verification using the ArcCHECK dosimetry system.

Authors:  Mu-Han Lin; Sion Koren; Iavor Veltchev; Jinsheng Li; Lu Wang; Robert A Price; C-M Ma
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.