What degree of accuracy is required and can be achieved in photon and neutron therapy?

B J Mijnheer, J J Battermann, A Wambersie.   

Abstract

In this paper an attempt is made to formulate criteria for the accuracy in the delivery of absorbed dose to a patient during photon or neutron therapy. These requirements are mainly based on the relative steepness of dose-effect curves for local tumour control and normal tissue damage. A review of these dose-effect curves after photon irradiation shows a great variety in steepness; the curves for normal tissue complications in general may be steeper than those for local tumour control. From these data a standard requirement for the combined uncertainty of type A (random) and type B (systematic), given as one relative standard deviation, in the absorbed dose delivery of 3.5% is proposed, even though it is known that in many cases larger values are acceptable and in a few special cases an even smaller value should be aimed at. From the available radiobiological and clinical data it can be concluded that no statistically significant difference can be observed in the relative steepness of dose-effect curves after photon or neutron irradiation. Similar limits will thus be requested in neutron therapy. The uncertainties in the various steps involved in the delivery of an absorbed dose to a point in a patient have been analysed for a treatment with two parallel-opposed beams. The results of this analysis showed that even for these simple treatment conditions, the required accuracy in the delivery of the absorbed dose cannot completely be obtained in photon therapy, and not nearly in neutron therapy. The uncertainties in physical, radiobiological and clinical approaches for weighting of the biological effectiveness of neutron radiation have been compared. The uncertainty in the RBE ratio will replace the type B uncertainty in the absorbed dose during patient treatment if the same dosimetry protocol is applied during biological and clinical procedures.

Entities:  

Mesh:

Year:  1987        PMID: 3107087     DOI: 10.1016/s0167-8140(87)80247-5

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  30 in total

1.  RBE, reference RBE and clinical RBE: applications of these concepts in hadron therapy.

Authors:  A Wambersie
Journal:  Strahlenther Onkol       Date:  1999-06       Impact factor: 3.621

2.  An analysis of an implantable dosimeter system for external beam therapy.

Authors:  Robert D Black; Charles W Scarantino; Gregory G Mann; Mitchell S Anscher; Robert D Ornitz; Benjamin E Nelms
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-09-01       Impact factor: 7.038

Review 3.  The use of medical images in planning and delivery of radiation therapy.

Authors:  I J Kalet; M M Austin-Seymour
Journal:  J Am Med Inform Assoc       Date:  1997 Sep-Oct       Impact factor: 4.497

4.  Effect of deformable registration on the dose calculated in radiation therapy planning CT scans of lung cancer patients.

Authors:  Alexandra R Cunliffe; Clay Contee; Samuel G Armato; Bradley White; Julia Justusson; Renuka Malik; Hania A Al-Hallaq
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

5.  What is the best way to evaluate clinical target volume for radiotherapy of brain tumors?

Authors:  Alba Fiorentino; Piernicola Pedicini; Rocchina Caivano; Vincenzo Fusco
Journal:  CNS Oncol       Date:  2013-11

6.  Pretreatment verification of dose calculation and delivery by means of measurements with PLEXITOM™ phantom.

Authors:  Paweł Wołowiec; Paweł Kukołowicz; Krzysztof Lis
Journal:  Rep Pract Oncol Radiother       Date:  2013-02-04

7.  The impact of computed tomography slice thickness on the assessment of stereotactic, 3D conformal and intensity-modulated radiotherapy of brain tumors.

Authors:  R Caivano; A Fiorentino; P Pedicini; G Califano; V Fusco
Journal:  Clin Transl Oncol       Date:  2013-09-20       Impact factor: 3.405

8.  Monte carlo simulation of bony heterogeneity effects on dose profile for small irradiation field in radiotherapy.

Authors:  Simone C Cardoso; Victor Gabriel L Alves; Luiz Antonio R da Rosa; Luciana T Campos; Delano V S Batista; Alessandro Facure
Journal:  PLoS One       Date:  2010-05-03       Impact factor: 3.240

9.  Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials.

Authors:  Catharine H Clark; Edwin G A Aird; Steve Bolton; Elizabeth A Miles; Andrew Nisbet; Julia A D Snaith; Russell A S Thomas; Karen Venables; David I Thwaites
Journal:  Br J Radiol       Date:  2015-09-02       Impact factor: 3.039

10.  Verification of setup errors in external beam radiation therapy using electronic portal imaging.

Authors:  K Krishna Murthy; Zakiya Al-Rahbi; S S Sivakumar; C A Davis; R Ravichandran; Kamal El Ghamrawy
Journal:  J Med Phys       Date:  2008-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.