Calibration of radiographs by a reference metal ball affects preoperative selection of implant size.

Lars Schropp1, Andreas Stavropoulos, Erik Gotfredsen, Ann Wenzel.   

Abstract

The aim was to evaluate the impact of a reference ball for calibration of periapical and panoramic radiographs on preoperative selection of implant size for three implant systems. Presurgical digital radiographs (70 panoramic, 43 periapical) from 70 patients scheduled for single-tooth implant treatment, recorded with a metal ball placed in the edentulous area, were evaluated by three observers with the intent to select the appropriate implant size. Four reference marks corresponding to the margins of the metal ball were manually placed on the digital image by means of computer software. Additionally, an implant with proper dimensions for the respective site was outlined by manually placing four reference marks. The diameter of the metal ball and the unadjusted length and width of the implant were calculated. Implant size was adjusted according to a "standard" calibration method (SCM; magnification factor 1.25 in panoramic images and 1.05 in periapical images) and according to a reference ball calibration method (RCM; true magnification). Based on the unadjusted as well as the adjusted implant dimensions, the implant size was selected among those available in a given implant system. For periapical radiographs, when comparing SCM and RCM with unadjusted implant dimensions, implant size changed in 42% and 58%, respectively. When comparing SCM and RCM, implant size changed in 24%. For panoramic radiographs, comparing SCM and RCM changed implant size in 48%. The use of a reference metal ball for calibration of periapical and panoramic radiographs when selecting implant size during treatment planning might be advantageous.

Entities:  

Mesh:

Year:  2009        PMID: 19221809     DOI: 10.1007/s00784-009-0257-5

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  20 in total

1.  Impact of conventional tomography on prediction of the appropriate implant size.

Authors:  L Schropp; A Wenzel; L Kostopoulos
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2001-10

2.  Effect of the vertical and horizontal distances between adjacent implants and between a tooth and an implant on the incidence of interproximal papilla.

Authors:  Jose Fabio Gastaldo; Patricia Ramos Cury; Wilson Roberto Sendyk
Journal:  J Periodontol       Date:  2004-09       Impact factor: 6.993

Review 3.  Impact of implant length and diameter on survival rates.

Authors:  Franck Renouard; David Nisand
Journal:  Clin Oral Implants Res       Date:  2006-10       Impact factor: 5.977

4.  Do longer implants improve clinical outcome in immediate loading?

Authors:  M Degidi; A Piattelli; G Iezzi; F Carinci
Journal:  Int J Oral Maxillofac Surg       Date:  2007-07-03       Impact factor: 2.789

5.  Changes in the pre-surgical treatment planning using conventional spiral tomography.

Authors:  Ana Flávia N Diniz; Elismauro F Mendonça; Claudio R Leles; Adérico S Guilherme; Marcelo P Cavalcante; Maria Alves G S Silva
Journal:  Clin Oral Implants Res       Date:  2008-03       Impact factor: 5.977

6.  Bone height measurements on panoramic radiographs: the effect of shape and position of edentulous mandibles.

Authors:  R H Batenburg; K Stellingsma; G M Raghoebar; A Vissink
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1997-10

7.  Image distortion in rotational panoramic radiography. VI. Distortion effects in sliding systems.

Authors:  G Tronje; U Welander; W D McDavid; C R Morris
Journal:  Acta Radiol Diagn (Stockh)       Date:  1982

8.  Analysis of incidence and associated factors with fractured implants: a retrospective study.

Authors:  S E Eckert; S J Meraw; E Cal; R K Ow
Journal:  Int J Oral Maxillofac Implants       Date:  2000 Sep-Oct       Impact factor: 2.804

9.  Development of a system for craniofacial analysis from monitor-displayed digital images.

Authors:  E Gotfredsen; J Kragskov; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  1999-03       Impact factor: 2.419

10.  A long-term follow-up study of non-submerged ITI implants in the treatment of totally edentulous jaws. Part I: Ten-year life table analysis of a prospective multicenter study with 1286 implants.

Authors:  Nicola Ferrigno; Mauro Laureti; Stefano Fanali; Guido Grippaudo
Journal:  Clin Oral Implants Res       Date:  2002-06       Impact factor: 5.977

View more
  13 in total

1.  Influence of the intergonial distance on image distortion in panoramic radiographs.

Authors:  D B S Ladeira; A D Cruz; S M Almeida; F N Bóscolo
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

2.  Spatial relation between a rigid (digital) intraoral X-ray receptor and longitudinal axes of maxillary teeth.

Authors:  Felix Roeder; Isabell von Rechenberg; Bernd d'Hoedt; Ralf Schulze
Journal:  Clin Oral Investig       Date:  2010-05-25       Impact factor: 3.573

Review 3.  Conventional radiography and cross-sectional imaging when planning dental implants in the anterior edentulous mandible to support an overdenture: a systematic review.

Authors:  A M Shelley; A-M Glenny; M Goodwin; P Brunton; K Horner
Journal:  Dentomaxillofac Radiol       Date:  2013-11-22       Impact factor: 2.419

4.  Ex vivo radiographic tooth length measurements with the reference sphere method (RSM).

Authors:  Felix Roeder; Dan Brüllmann; Bernd d'Hoedt; Ralf Schulze
Journal:  Clin Oral Investig       Date:  2009-10-15       Impact factor: 3.573

5.  Accuracy of vertical height measurements on direct digital panoramic radiographs using posterior mandibular implants and metal balls as reference objects.

Authors:  L Vazquez; Y Nizamaldin; C Combescure; R Nedir; M Bischof; D M Dohan Ehrenfest; J-P Carrel; U C Belser
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

Review 6.  Efficacy of CBCT for assessment of impacted mandibular third molars: a review - based on a hierarchical model of evidence.

Authors:  L H Matzen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

7.  Radiographic signs of pathology determining removal of an impacted mandibular third molar assessed in a panoramic image or CBCT.

Authors:  Louise H Matzen; Lars Schropp; Rubens Spin-Neto; Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2016-10-25       Impact factor: 2.419

8.  Pose determination of a blade implant in three dimensions from a single two-dimensional radiograph.

Authors:  Paolo Toti; Antonio Barone; Simone Marconcini; Giovanni Battista Menchini-Fabris; Ranieri Martuscelli; Ugo Covani
Journal:  Dentomaxillofac Radiol       Date:  2018-01-11       Impact factor: 2.419

9.  Use of digital panoramic radiography as an auxiliary means of low bone mineral density detection in post-menopausal women.

Authors:  C S Valerio; A M Trindade; E T Mazzieiro; T P Amaral; F R Manzi
Journal:  Dentomaxillofac Radiol       Date:  2013-09-04       Impact factor: 2.419

10.  Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography.

Authors:  Mona A Abbassy; Hanady M Sabban; Ali H Hassan; Khalid H Zawawi
Journal:  Saudi Med J       Date:  2015-11       Impact factor: 1.484

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.