Literature DB >> 10522202

Development of a system for craniofacial analysis from monitor-displayed digital images.

E Gotfredsen1, J Kragskov, A Wenzel.   

Abstract

OBJECTIVES: To develop a program for clinical craniofacial analysis directly on monitor-displayed digital images.
METHODS: The program was developed in VisualBasic (Microsoft, Redwood WA, USA), using Access (Microsoft) database, for landmark identification analysis and data storage. It runs on Windows95 (Microsoft).
RESULTS: The following established cephalometric analyses were included in the program: Bjork, Down, Frontal, Jarabak, Occlusogram, Rickett and Tweed. In addition, an orthodontist can simply define his own analyses. If he wants to identify a particular landmark, he clicks on its name at the top of the screen, and the definition including a drawing will be shown. If specified in the analysis selected, reference lines or templates are drawn using the identified landmarks. Soft tissues can be drawn either freehand or using the 'soft tissue detection' that generates an outline from the grey-level histogram. The program has been implemented at the Royal Dental College and at the Department of Maxillofacial Surgery and at the Cleft Palate Centre, Aarhus University Hospital.
CONCLUSION: A program (PorDiosW) has been developed which has facilitated cephalometric analysis from digital lateral and frontal skull radiographs and digital photographs. The program has been successfully applied in patients with cleft lip and palate and other developmental craniofacial anomalies before and after surgery.

Entities:  

Mesh:

Year:  1999        PMID: 10522202     DOI: 10.1038/sj/dmfr/4600420

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  5 in total

1.  Five-year results of guided tissue regeneration in combination with deproteinized bovine bone (Bio-Oss) in the treatment of intrabony periodontal defects: a case series report.

Authors:  Andreas Stavropoulos; Thorkild Karring
Journal:  Clin Oral Investig       Date:  2005-07-12       Impact factor: 3.573

2.  Calibration of radiographs by a reference metal ball affects preoperative selection of implant size.

Authors:  Lars Schropp; Andreas Stavropoulos; Erik Gotfredsen; Ann Wenzel
Journal:  Clin Oral Investig       Date:  2009-02-17       Impact factor: 3.573

3.  Accuracy of scanography using storage phosphor plate systems and film for assessment of mandibular third molars.

Authors:  L H Matzen; J Christensen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

4.  Radiographic observers' ability to recognize patient movement during cone beam CT.

Authors:  R Spin-Neto; L H Matzen; L Schropp; G S Liedke; E Gotfredsen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2014-02-26       Impact factor: 2.419

5.  Comparative Study of Skeletal Stability between Postoperative Skeletal Intermaxillary Fixation and No Skeletal Fixation after Bilateral Sagittal Split Ramus Osteotomy: an 18 Months Retrospective Study.

Authors:  Jens Hartlev; Erik Godtfredsen; Niels Trolle Andersen; Thomas Jensen
Journal:  J Oral Maxillofac Res       Date:  2014-04-01
  5 in total