Literature DB >> 11055133

Analysis of incidence and associated factors with fractured implants: a retrospective study.

S E Eckert1, S J Meraw, E Cal, R K Ow.   

Abstract

Osseointegrated threaded titanium screw-type implants rarely lose integration after the first year of clinical function. Implant failure can occur for other reasons, with implant fracture being one of the major reasons for late failure. The purpose of the present study was to determine the incidence of implant fracture in completely edentulous and partially edentulous arches and to determine what factors may predispose an implant to a higher fracture risk. A retrospective evaluation of 4,937 implants was performed to determine the incidence of and factors common to fractured implants from a sample of implants placed and restored in one institutional setting. Based on the results of this study, the following observations were made: implants fracture at similar rates in the maxilla as in the mandible (0.6%), implant fractures occur more frequently in partially edentulous restorations (1.5%) than in restorations of completely edentulous arches (0.2%), all observed fractures occurred with commercially pure 3.75-mm-diameter threaded implants, and prosthetic or abutment screw loosening preceded implant fracture for the majority of the implants. More studies would be helpful to further explore the relationship and progression of factors associated with implant fracture.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11055133

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  22 in total

1.  Calibration of radiographs by a reference metal ball affects preoperative selection of implant size.

Authors:  Lars Schropp; Andreas Stavropoulos; Erik Gotfredsen; Ann Wenzel
Journal:  Clin Oral Investig       Date:  2009-02-17       Impact factor: 3.573

2.  Management of fractured implant case using loop connector fixed partial denture.

Authors:  Ashish Yadav; Aratee Gupta; Amrit Tandan; Sulabh Kumar
Journal:  BMJ Case Rep       Date:  2013-05-24

3.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

4.  Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

Authors:  Yuanyuan Duan; Jorge A Gonzalez; Pratim A Kulkarni; William W Nagy; Jason A Griggs
Journal:  Dent Mater       Date:  2018-06-18       Impact factor: 5.304

5.  Implant fracture under dynamic fatigue loading: influence of embedded angle and depth of implant.

Authors:  Hiroaki Suzuki; Yoshiaki Hata; Fumihiko Watanabe
Journal:  Odontology       Date:  2015-12-23       Impact factor: 2.634

Review 6.  Dental implant fractures - aetiology, treatment and case report.

Authors:  Coelho Goiato Marcelo; Marcela Filié Haddad; Humberto Gennari Filho; Luiz Marcelo Ribeiro Villa; Daniela Micheline Dos Santos; Alves Pesqueira Aldiéris
Journal:  J Clin Diagn Res       Date:  2014-03-15

7.  SEM Analysis and Management of Fracture Dental Implant.

Authors:  Archana Singh; Ankita Singh; Rajul Vivek; T P Chaturvedi; Pankaj Chauhan; Shruti Gupta
Journal:  Case Rep Dent       Date:  2013-04-23

8.  Fracture of abutment screw supporting a cemented implant-retained prosthesis with external hexagon connection: a case report with sem evaluation.

Authors:  Mariana Diniz Bisi Santos; Arthur Braga Pfeifer; Marcos Rogério Pupo Silva; Claudio Luiz Sendyk; Wilson Roberto Sendyk
Journal:  J Appl Oral Sci       Date:  2007-04       Impact factor: 2.698

9.  Accuracy of Implant Position Transfer and Surface Detail Reproduction with Different Impression Materials and Techniques.

Authors:  Marzieh Alikhasi; Hakimeh Siadat; Elaheh Beyabanaki; Mohammad Javad Kharazifard
Journal:  J Dent (Tehran)       Date:  2015-10

Review 10.  New Ti-Alloys and Surface Modifications to Improve the Mechanical Properties and the Biological Response to Orthopedic and Dental Implants: A Review.

Authors:  Yvoni Kirmanidou; Margarita Sidira; Maria-Eleni Drosou; Vincent Bennani; Athina Bakopoulou; Alexander Tsouknidas; Nikolaos Michailidis; Konstantinos Michalakis
Journal:  Biomed Res Int       Date:  2016-01-14       Impact factor: 3.411

View more