Literature DB >> 19190915

Remodelling of the aortic root in severe tricuspid aortic stenosis: implications for transcatheter aortic valve implantation.

Paul Stolzmann1, Joseph Knight, Lotus Desbiolles, Willibald Maier, Hans Scheffel, André Plass, Vartan Kurtcuoglu, Sebastian Leschka, Dimos Poulikakos, Borut Marincek, Hatem Alkadhi.   

Abstract

Detailed knowledge of aortic root geometry is a prerequisite to anticipate complications of transcatheter aortic valve (TAV) implantation. We determined coronary ostial locations and aortic root dimensions in patients with aortic stenosis (AS) and compared these values with normal subjects using computed tomography (CT). One hundred consecutive patients with severe tricuspid AS and 100 consecutive patients without valvular pathology (referred to as the controls) undergoing cardiac dual-source CT were included. Distances from the aortic annulus (AA) to the left coronary ostium (LCO), right coronary ostium (RCO), the height of the left coronary sinus (HLS), right coronary sinus (HRS), and aortic root dimensions [diameters of AA, sinus of Valsalva (SV), and sino-tubular junction (STJ)] were measured. LCO and RCO were 14.9 +/- 3.2 mm (8.2-25.9) and 16.8 +/- 3.6 mm (12.0-25.7) in the controls, 15.5 +/- 2.9 mm (8.8-24.3) and 17.3 +/- 3.6 mm (7.3-26.0) in patients with AS. Controls and patients with AS had similar values for LCO (P = 0.18), RCO (P = 0.33) and HLS (P = 0.88), whereas HRS (P < 0.05) was significantly larger in patients with AS. AA (r = 0.55,P < 0.001), SV (r = 0.54,P < 0.001), and STJ (r = 0.52,P < 0.001) significantly correlated with the body surface area in the controls; whereas no correlation was found in patients with AS. Patients with AS had significantly larger AA (P < 0.01) and STJ (P < 0.01) diameters when compared with the controls. In patients with severe tricuspid AS, coronary ostial locations were similar to the controls, but a transverse remodelling of the aortic root was recognized. Owing to the large distribution of ostial locations and the dilatation of the aortic root, CT is recommended before TAV implantation in each patient.

Entities:  

Mesh:

Year:  2009        PMID: 19190915     DOI: 10.1007/s00330-009-1302-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  36 in total

1.  The anatomy of the aortic root.

Authors:  Denis Berdajs; Patonay Lajos; Marko Turina
Journal:  Cardiovasc Surg       Date:  2002-08

2.  Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography.

Authors:  David Messika-Zeitoun; Marie-Christine Aubry; Delphine Detaint; Lawrence F Bielak; Patricia A Peyser; Patrick F Sheedy; Stephen T Turner; Jerome F Breen; Christopher Scott; A Jamil Tajik; Maurice Enriquez-Sarano
Journal:  Circulation       Date:  2004-07-12       Impact factor: 29.690

3.  ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons.

Authors:  Robert O Bonow; Blase A Carabello; Kanu Chatterjee; Antonio C de Leon; David P Faxon; Michael D Freed; William H Gaasch; Bruce Whitney Lytle; Rick A Nishimura; Patrick T O'Gara; Robert A O'Rourke; Catherine M Otto; Pravin M Shah; Jack S Shanewise; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Elliott M Antman; Valentin Fuster; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Bruce W Lytle; Rick Nishimura; Richard L Page; Barbara Riegel
Journal:  J Am Coll Cardiol       Date:  2006-08-01       Impact factor: 24.094

4.  Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area.

Authors:  Gudrun M Feuchtner; Silvana Müller; Johannes Bonatti; Thomas Schachner; Corinna Velik-Salchner; Otmar Pachinger; Wolfgang Dichtl
Journal:  AJR Am J Roentgenol       Date:  2007-07       Impact factor: 3.959

5.  Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing.

Authors:  Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Andre Plass; Oliver Gaemperli; Ines Valenta; Lars Husmann; Thomas G Flohr; Michele Genoni; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-08       Impact factor: 6.016

6.  Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

Authors:  Alain Cribier; Helene Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Genevieve Derumeaux; Frederic Anselme; François Laborde; Martin B Leon
Journal:  Circulation       Date:  2002-12-10       Impact factor: 29.690

7.  Simplified calculation of body-surface area.

Authors:  R D Mosteller
Journal:  N Engl J Med       Date:  1987-10-22       Impact factor: 91.245

8.  Dimensions and geometric relationships of the human aortic valve as a function of pressure.

Authors:  M Swanson; R E Clark
Journal:  Circ Res       Date:  1974-12       Impact factor: 17.367

9.  Percutaneous aortic valve replacement: an experimental study. I. Studies on implantation.

Authors:  Georg Lutter; Daniela Kuklinski; Georg Berg; Patrick Von Samson; Juergen Martin; Michael Handke; Peter Uhrmeister; Friedhelm Beyersdorf
Journal:  J Thorac Cardiovasc Surg       Date:  2002-04       Impact factor: 5.209

10.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience.

Authors:  Alain Cribier; Helene Eltchaninoff; Christophe Tron; Fabrice Bauer; Carla Agatiello; Deborah Nercolini; Sydney Tapiero; Pierre-Yves Litzler; Jean-Paul Bessou; Vasilis Babaliaros
Journal:  J Am Coll Cardiol       Date:  2006-02-09       Impact factor: 24.094

View more
  14 in total

1.  High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization.

Authors:  Christoph Karlo; Sebastian Leschka; Robert Paul Goetti; Gudrun Feuchtner; Lotus Desbiolles; Paul Stolzmann; Andre Plass; Volkmar Falk; Borut Marincek; Hatem Alkadhi; Stephan Baumüller
Journal:  Eur Radiol       Date:  2010-07-31       Impact factor: 5.315

Review 2.  In vivo imaging and computational analysis of the aortic root. Application in clinical research and design of transcatheter aortic valve systems.

Authors:  Paul Schoenhagen; Alexander Hill; Tim Kelley; Zoran Popovic; Sandra S Halliburton
Journal:  J Cardiovasc Transl Res       Date:  2011-04-12       Impact factor: 4.132

3.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

4.  Geometry of the left ventricular outflow tract assessed by 3D TEE in patients with aortic stenosis: impact of upper septal hypertrophy on measurements of Doppler-derived left ventricular stroke volume.

Authors:  Dan Koto; Masaki Izumo; Takafumi Machida; Kengo Suzuki; Kihei Yoneyama; Tomomi Suzuki; Ryo Kamijima; Yasuyuki Kobayashi; Tomoo Harada; Yoshihiro J Akashi
Journal:  J Echocardiogr       Date:  2018-05-24

5.  Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation.

Authors:  Johannes Rixe; Annika Schuhbaeck; Christoph Liebetrau; Helge Moellmann; Holger M Nef; Sebastian Szardien; Roland Brandt; Joern Schmitt; Thomas Neumann; Christian Schneider; Gabriele Krombach; Christian W Hamm; Stephan Achenbach; Andreas Rolf
Journal:  Eur Radiol       Date:  2012-06-12       Impact factor: 5.315

6.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment.

Authors:  Qian Wang; Eric Sirois; Wei Sun
Journal:  J Biomech       Date:  2012-06-13       Impact factor: 2.712

7.  Emerging approaches of transcatheter valve repair/insertion.

Authors:  Maurizio Taramasso; Micaela Cioni; Andrea Giacomini; Iassen Michev; Cosmo Godino; Matteo Montorfano; Antonio Colombo; Ottavio Alfieri; Francesco Maisano
Journal:  Cardiol Res Pract       Date:  2010-07-25       Impact factor: 1.866

8.  Comparison between cardiovascular magnetic resonance and transthoracic Doppler echocardiography for the estimation of effective orifice area in aortic stenosis.

Authors:  Julio Garcia; Lyes Kadem; Eric Larose; Marie-Annick Clavel; Philippe Pibarot
Journal:  J Cardiovasc Magn Reson       Date:  2011-04-28       Impact factor: 5.364

9.  A systematic approach for analysis, interpretation, and reporting of coronary CTA studies.

Authors:  Christoph A Karlo; Sebastian Leschka; Paul Stolzmann; Nicola Glaser-Gallion; Simon Wildermuth; Hatem Alkadhi
Journal:  Insights Imaging       Date:  2012-05-01

10.  The role of computed tomography in pre-procedural planning of cardiovascular surgery and intervention.

Authors:  Prabhakar Rajiah; Paul Schoenhagen
Journal:  Insights Imaging       Date:  2013-08-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.