Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment.

Qian Wang1, Eric Sirois, Wei Sun.   

Abstract

The objective of this study was to develop a patient-specific computational model to quantify the biomechanical interaction between the transcatheter aortic valve (TAV) stent and the stenotic aortic valve during TAV intervention. Finite element models of a patient-specific stenotic aortic valve were reconstructed from multi-slice computed tomography (MSCT) scans, and TAV stent deployment into the aortic root was simulated. Three initial aortic root geometries of this patient were analyzed: (a) aortic root geometry directly reconstructed from MSCT scans, (b) aortic root geometry at the rapid right ventricle pacing phase, and (c) aortic root geometry with surrounding myocardial tissue. The simulation results demonstrated that stress, strain, and contact forces of the aortic root model directly reconstructed from MSCT scans were significantly lower than those of the model at the rapid ventricular pacing phase. Moreover, the presence of surrounding myocardium slightly increased the mechanical responses. Peak stresses and strains were observed around the calcified regions in the leaflets, suggesting the calcified leaflets helped secure the stent in position. In addition, these elevated stresses induced during TAV stent deployment indicated a possibility of tissue tearing and breakdown of calcium deposits, which might lead to an increased risk of stroke. The potential of paravalvular leak and occlusion of coronary ostia can be evaluated from simulated post-deployment aortic root geometries. The developed computational models could be a valuable tool for pre-operative planning of TAV intervention and facilitate next generation TAV device design.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22698832      PMCID: PMC3392407          DOI: 10.1016/j.jbiomech.2012.05.008

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  38 in total

1.  Fatigue and life prediction for cobalt-chromium stents: A fracture mechanics analysis.

Authors:  Ramesh V Marrey; Robert Burgermeister; Randy B Grishaber; R O Ritchie
Journal:  Biomaterials       Date:  2005-11-02       Impact factor: 12.479

2.  Rapid pacing to facilitate transcatheter prosthetic heart valve implantation.

Authors:  John G Webb; Sanjeevan Pasupati; Leslie Achtem; Christopher R Thompson
Journal:  Catheter Cardiovasc Interv       Date:  2006-08       Impact factor: 2.692

3.  Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis.

Authors:  John G Webb; Sanjeevan Pasupati; Karin Humphries; Christopher Thompson; Lukas Altwegg; Robert Moss; Ajay Sinhal; Ronald G Carere; Brad Munt; Donald Ricci; Jian Ye; Anson Cheung; Sam V Lichtenstein
Journal:  Circulation       Date:  2007-07-23       Impact factor: 29.690

4.  A computational tool to support pre-operative planning of stentless aortic valve implant.

Authors:  F Auricchio; M Conti; S Morganti; P Totaro
Journal:  Med Eng Phys       Date:  2011-06-11       Impact factor: 2.242

5.  Remodeling of the constitutive equation while a blood vessel remodels itself under stress.

Authors:  Y C Fung; S Q Liu; J B Zhou
Journal:  J Biomech Eng       Date:  1993-11       Impact factor: 2.097

Review 6.  Hyperelastic modelling of arterial layers with distributed collagen fibre orientations.

Authors:  T Christian Gasser; Ray W Ogden; Gerhard A Holzapfel
Journal:  J R Soc Interface       Date:  2006-02-22       Impact factor: 4.118

7.  Anisotropic mechanical properties of tissue components in human atherosclerotic plaques.

Authors:  Gerhard A Holzapfel; Gerhard Sommer; Peter Regitnig
Journal:  J Biomech Eng       Date:  2004-10       Impact factor: 2.097

8.  Observations on bone formation and remodelling in advanced atherosclerotic lesions of human carotid arteries.

Authors:  M Jeziorska; C McCollum; D E Wooley
Journal:  Virchows Arch       Date:  1998-12       Impact factor: 4.064

9.  Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults.

Authors:  Rachid Zegdi; Vlad Ciobotaru; Miléna Noghin; Ghassan Sleilaty; Antoine Lafont; Christian Latrémouille; Alain Deloche; Jean-Noël Fabiani
Journal:  J Am Coll Cardiol       Date:  2008-02-05       Impact factor: 24.094

10.  Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome.

Authors:  Eberhard Grube; Gerhard Schuler; Lutz Buellesfeld; Ulrich Gerckens; Axel Linke; Peter Wenaweser; Barthel Sauren; Friedrich-Wilhelm Mohr; Thomas Walther; Bernfried Zickmann; Stein Iversen; Thomas Felderhoff; Raymond Cartier; Raoul Bonan
Journal:  J Am Coll Cardiol       Date:  2007-06-06       Impact factor: 24.094

View more
  29 in total

1.  Modeling risk of coronary obstruction during transcatheter aortic valve replacement.

Authors:  Megan Heitkemper; Hoda Hatoum; Amirsepehr Azimian; Breandan Yeats; Jennifer Dollery; Bryan Whitson; Greg Rushing; Juan Crestanello; Scott M Lilly; Lakshmi Prasad Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2019-05-18       Impact factor: 5.209

2.  The impact of balloon-expandable transcatheter aortic valve replacement on concomitant mitral regurgitation: a comprehensive computational analysis.

Authors:  Andrés Caballero; Wenbin Mao; Raymond McKay; Wei Sun
Journal:  J R Soc Interface       Date:  2019-08-14       Impact factor: 4.118

3.  Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: A fatigue simulation study.

Authors:  Caitlin Martin; Wei Sun
Journal:  J Biomech       Date:  2015-08-07       Impact factor: 2.712

4.  A deep learning approach to estimate stress distribution: a fast and accurate surrogate of finite-element analysis.

Authors:  Liang Liang; Minliang Liu; Caitlin Martin; Wei Sun
Journal:  J R Soc Interface       Date:  2018-01       Impact factor: 4.118

5.  Evaluation of transcatheter heart valve biomaterials: Computational modeling using bovine and porcine pericardium.

Authors:  Fatiesa Sulejmani; Andrés Caballero; Caitlin Martin; Thuy Pham; Wei Sun
Journal:  J Mech Behav Biomed Mater       Date:  2019-05-17

Review 6.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

Review 7.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

8.  Quantification of biomechanical interaction of transcatheter aortic valve stent deployed in porcine and ovine hearts.

Authors:  Joseph Mummert; Eric Sirois; Wei Sun
Journal:  Ann Biomed Eng       Date:  2012-11-17       Impact factor: 3.934

9.  Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root.

Authors:  Wenbin Mao; Qian Wang; Susheel Kodali; Wei Sun
Journal:  J Biomech Eng       Date:  2018-10-01       Impact factor: 2.097

Review 10.  Computational modeling of cardiac valve function and intervention.

Authors:  Wei Sun; Caitlin Martin; Thuy Pham
Journal:  Annu Rev Biomed Eng       Date:  2014-04-16       Impact factor: 9.590

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.