Literature DB >> 22688129

Multi-detector computed tomography is equivalent to trans-oesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation.

Johannes Rixe1, Annika Schuhbaeck, Christoph Liebetrau, Helge Moellmann, Holger M Nef, Sebastian Szardien, Roland Brandt, Joern Schmitt, Thomas Neumann, Christian Schneider, Gabriele Krombach, Christian W Hamm, Stephan Achenbach, Andreas Rolf.   

Abstract

OBJECTIVES: In transcatheter aortic valve implantation (TAVI), assessment of the aortic annulus is mandatory. We sought to investigate the correlation between trans-oesophageal echocardiography (TEE) and multi-detector computed tomography (MDCT) for annulus diameter assessment before TAVI.
METHODS: A total of 122 patients (67 male, mean age 84 ± 6 years) underwent MDCT and TEE for TAVI planning. In TEE annulus diameters were obtained in a long-axis view at diastole. MDCT data were evaluated using MPR images, and corresponding projections were adjusted for MDCT and TEE. Patients were classified by the predominant localisation of aortic valve calcifications, and annulus diameters between TEE and MDCT were correlated. Additionally, the eccentricity of the aortic annulus was calculated.
RESULTS: Mean eccentricity of the aortic annulus determined by MDCT was 0.34 ± 0.17, with no difference according to valve calcification. Regarding the aortic annulus diameter, the mean values measured were 24.3 ± 2.1 mm in MDCT and 24.0 ± 2.5 mm in TEE (P < 0.0001 for agreement).
CONCLUSIONS: Independent of the pattern of aortic valve calcification, close correlation is found between CT and TEE measurements of the aortic annulus diameter. In addition, CT demonstrates the non-circular shape of the aortic annulus. KEY POINTS: Accurate assessment of aortic annulus before transcatheter aortic valve implantation is crucial. Trans-oesophageal echocardiography has been the preferred method for aortic annulus assessment. We demonstrated a strong correlation between TEE and CT for annulus dimensions. CT reliably demonstrates the non-circular shape of the aortic annulus. CT could therefore be generally used for aortic annulus assessment before TAVI.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22688129     DOI: 10.1007/s00330-012-2530-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

1.  To operate or not on elderly patients with aortic stenosis: the decision and its consequences.

Authors:  B J Bouma; R B van Den Brink; J H van Der Meulen; H A Verheul; E C Cheriex; H P Hamer; E Dekker; K I Lie; J G Tijssen
Journal:  Heart       Date:  1999-08       Impact factor: 5.994

2.  ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons.

Authors:  Robert O Bonow; Blase A Carabello; Kanu Chatterjee; Antonio C de Leon; David P Faxon; Michael D Freed; William H Gaasch; Bruce Whitney Lytle; Rick A Nishimura; Patrick T O'Gara; Robert A O'Rourke; Catherine M Otto; Pravin M Shah; Jack S Shanewise; Sidney C Smith; Alice K Jacobs; Cynthia D Adams; Jeffrey L Anderson; Elliott M Antman; Valentin Fuster; Jonathan L Halperin; Loren F Hiratzka; Sharon A Hunt; Bruce W Lytle; Rick Nishimura; Richard L Page; Barbara Riegel
Journal:  J Am Coll Cardiol       Date:  2006-08-01       Impact factor: 24.094

3.  Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation.

Authors:  Ertunc Altiok; Ralf Koos; Jörg Schröder; Kathrin Brehmer; Sandra Hamada; Michael Becker; Andreas H Mahnken; Mohammad Almalla; Guido Dohmen; Rüdiger Autschbach; Nikolaus Marx; Rainer Hoffmann
Journal:  Heart       Date:  2011-06-23       Impact factor: 5.994

4.  Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?

Authors:  Carl J Schultz; Adriaan Moelker; Nicolo Piazza; Apostolos Tzikas; Amber Otten; Rutger J Nuis; Lisan A Neefjes; Robert J van Geuns; Pim de Feyter; Gabriel Krestin; Patrick W Serruys; Peter P T de Jaegere
Journal:  Eur Heart J       Date:  2009-12-07       Impact factor: 29.983

5.  Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description.

Authors:  Alain Cribier; Helene Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Genevieve Derumeaux; Frederic Anselme; François Laborde; Martin B Leon
Journal:  Circulation       Date:  2002-12-10       Impact factor: 29.690

6.  The effect of aortic valve replacement on survival.

Authors:  F Schwarz; P Baumann; J Manthey; M Hoffmann; G Schuler; H C Mehmel; W Schmitz; W Kübler
Journal:  Circulation       Date:  1982-11       Impact factor: 29.690

7.  Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement.

Authors:  Laurens F Tops; David A Wood; Victoria Delgado; Joanne D Schuijf; John R Mayo; Sanjeevan Pasupati; Frouke P L Lamers; Ernst E van der Wall; Martin J Schalij; John G Webb; Jeroen J Bax
Journal:  JACC Cardiovasc Imaging       Date:  2008-05

8.  Role of multislice computed tomography in transcatheter aortic valve replacement.

Authors:  David A Wood; Laurens F Tops; John R Mayo; Sanjeevan Pasupati; Martin J Schalij; Karin Humphries; May Lee; Abdullah Al Ali; Brad Munt; Rob Moss; Christopher R Thompson; Jeroen J Bax; John G Webb
Journal:  Am J Cardiol       Date:  2009-05-01       Impact factor: 2.778

9.  Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly.

Authors:  Fleur Descoutures; Dominique Himbert; Laurent Lepage; Bernard Iung; Delphine Détaint; Didier Tchetche; Eric Brochet; Yves Castier; Jean-Pol Depoix; Patrick Nataf; Alec Vahanian
Journal:  Eur Heart J       Date:  2008-03-06       Impact factor: 29.983

10.  Remodelling of the aortic root in severe tricuspid aortic stenosis: implications for transcatheter aortic valve implantation.

Authors:  Paul Stolzmann; Joseph Knight; Lotus Desbiolles; Willibald Maier; Hans Scheffel; André Plass; Vartan Kurtcuoglu; Sebastian Leschka; Dimos Poulikakos; Borut Marincek; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2009-02-04       Impact factor: 5.315

View more
  6 in total

Review 1.  [Transcatheter aortic valve implantation (TAVI)].

Authors:  H Möllmann; W-K Kim; T Walther; C Hamm
Journal:  Internist (Berl)       Date:  2013-12       Impact factor: 0.743

2.  Optimal pre-TAVR annulus sizing in patients with bicuspid aortic valve: area-derived perimeter by CT is the best-correlated measure with intraoperative sizing.

Authors:  Yuan Wang; Moyang Wang; Guanyuan Song; Wei Wang; Bin Lv; Hao Wang; Yongjian Wu
Journal:  Eur Radiol       Date:  2018-06-20       Impact factor: 5.315

3.  Aortic root dimensions are predominantly determined by genetic factors: a classical twin study.

Authors:  Csilla Celeng; Márton Kolossváry; Attila Kovács; Andrea Ágnes Molnár; Bálint Szilveszter; Tamás Horváth; Mihály Károlyi; Ádám L Jermendy; Ádám D Tárnoki; Dávid L Tárnoki; Júlia Karády; Szilard Voros; György Jermendy; Béla Merkely; Pál Maurovich-Horvat
Journal:  Eur Radiol       Date:  2016-09-22       Impact factor: 5.315

4.  Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement.

Authors:  Simon S Martin; Moritz H Albrecht; Julian L Wichmann; Kristina Hüsers; Jan-Erik Scholtz; Christian Booz; Boris Bodelle; Ralf W Bauer; Sarah C Metzger; Thomas J Vogl; Thomas Lehnert
Journal:  Eur Radiol       Date:  2016-05-28       Impact factor: 5.315

5.  Comparison of aortic root dimension changes during cardiac cycle between the patients with and without aortic valve calcification using ECG-gated 64-slice and dual-source 256-slice computed tomography scanners: results of a multicenter study.

Authors:  Abbas Arjmand Shabestari; Ramin Pourghorban; Mahmood Tehrai; Hamidreza Pouraliakbar; Taraneh Faghihi Langroudi; Hooman Bakhshandeh; Seifollah Abdi
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-13       Impact factor: 2.357

6.  Retrospectively ECG-gated helical vs. non-ECG-synchronized high-pitch CTA of the aortic root for TAVI planning.

Authors:  Barbora Horehledova; Casper Mihl; Ellen Boswijk; Genevieve A J C Crombag; Estelle C Nijssen; Patty J Nelemans; Leo F Veenstra; Joachim E Wildberger; Marco Das
Journal:  PLoS One       Date:  2020-05-12       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.