Three-dimensional linear system analysis for breast tomosynthesis.

Bo Zhao1, Wei Zhao.   

Abstract

The optimization of digital breast tomosynthesis (DBT) geometry and reconstruction is crucial for the clinical translation of this exciting new imaging technique. In the present work, the authors developed a three-dimensional (3D) cascaded linear system model for DBT to investigate the effects of detector performance, imaging geometry, and image reconstruction algorithm on the reconstructed image quality. The characteristics of a prototype DBT system equipped with an amorphous selenium flat-panel detector and filtered backprojection reconstruction were used as an example in the implementation of the linear system model. The propagation of signal and noise in the frequency domain was divided into six cascaded stages incorporating the detector performance, imaging geometry, and reconstruction filters. The reconstructed tomosynthesis imaging quality was characterized by spatial frequency dependent presampling modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) in 3D. The results showed that both MTF and NPS were affected by the angular range of the tomosynthesis scan and the reconstruction filters. For image planes parallel to the detector (in-plane), MTF at low frequencies was improved with increase in angular range. The shape of the NPS was affected by the reconstruction filters. Noise aliasing in 3D could be introduced by insufficient voxel sampling, especially in the z (slice-thickness) direction where the sampling distance (slice thickness) could be more than ten times that for in-plane images. Aliasing increases the noise at high frequencies, which causes degradation in DQE. Application of a reconstruction filter that limits the frequency components beyond the Nyquist frequency in the z direction, referred to as the slice thickness filter, eliminates noise aliasing and improves 3D DQE. The focal spot blur, which arises from continuous tube travel during tomosynthesis acquisition, could degrade DQE significantly because it introduces correlation in signal only, not NPS.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19175081      PMCID: PMC2673606          DOI: 10.1118/1.2996014

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Evaluation of linear and nonlinear tomosynthetic reconstruction methods in digital mammography.

Authors:  S Suryanarayanan; A Karellas; S Vedantham; S P Baker; S J Glick; C J D'Orsi; R L Webber
Journal:  Acad Radiol       Date:  2001-03       Impact factor: 3.173

2.  Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.

Authors:  Wei Zhao; W G Ji; Anne Debrie; J A Rowlands
Journal:  Med Phys       Date:  2003-02       Impact factor: 4.071

3.  A framework for noise-power spectrum analysis of multidimensional images.

Authors:  J H Siewerdsen; I A Cunningham; D A Jaffray
Journal:  Med Phys       Date:  2002-11       Impact factor: 4.071

4.  A comparison of reconstruction algorithms for breast tomosynthesis.

Authors:  Tao Wu; Richard H Moore; Elizabeth A Rafferty; Daniel B Kopans
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

5.  Experimental validation of a three-dimensional linear system model for breast tomosynthesis.

Authors:  Bo Zhao; Jun Zhou; Yue-Houng Hu; Thomas Mertelmeier; Jasmina Ludwig; Wei Zhao
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Tomographic mammography using a limited number of low-dose cone-beam projection images.

Authors:  Tao Wu; Alexander Stewart; Martin Stanton; Thomas McCauley; Walter Phillips; Daniel B Kopans; Richard H Moore; Jeffrey W Eberhard; Beale Opsahl-Ong; Loren Niklason; Mark B Williams
Journal:  Med Phys       Date:  2003-03       Impact factor: 4.071

7.  The noise power spectrum of CT images.

Authors:  M F Kijewski; P F Judy
Journal:  Phys Med Biol       Date:  1987-05       Impact factor: 3.609

8.  Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function.

Authors:  K Faulkner; B M Moores
Journal:  Phys Med Biol       Date:  1984-11       Impact factor: 3.609

9.  The noise power spectrum in computed X-ray tomography.

Authors:  S J Riederer; N J Pelc; D A Chesler
Journal:  Phys Med Biol       Date:  1978-05       Impact factor: 3.609

10.  Detectability in computed tomographic images.

Authors:  K M Hanson
Journal:  Med Phys       Date:  1979 Sep-Oct       Impact factor: 4.071

View more
  30 in total

1.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

2.  Anatomical background and generalized detectability in tomosynthesis and cone-beam CT.

Authors:  G J Gang; D J Tward; J Lee; J H Siewerdsen
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  A novel solid-angle tomosynthesis (SAT) scanning scheme.

Authors:  Jin Zhang; Cedric Yu
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

5.  Experimental validation of a three-dimensional linear system model for breast tomosynthesis.

Authors:  Bo Zhao; Jun Zhou; Yue-Houng Hu; Thomas Mertelmeier; Jasmina Ludwig; Wei Zhao
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Image artifacts in digital breast tomosynthesis: investigation of the effects of system geometry and reconstruction parameters using a linear system approach.

Authors:  Yue-Houng Hu; Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  Oblique reconstructions in tomosynthesis. II. Super-resolution.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

8.  Oblique reconstructions in tomosynthesis. I. Linear systems theory.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

9.  Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

Authors:  Grace J Gang; Wojciech Zbijewski; J Webster Stayman; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

10.  Digital breast tomosynthesis versus digital mammography: a clinical performance study.

Authors:  Gisella Gennaro; Alicia Toledano; Cosimo di Maggio; Enrica Baldan; Elisabetta Bezzon; Manuela La Grassa; Luigi Pescarini; Ilaria Polico; Alessandro Proietti; Aida Toffoli; Pier Carlo Muzzio
Journal:  Eur Radiol       Date:  2009-12-22       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.