Literature DB >> 15487747

A comparison of reconstruction algorithms for breast tomosynthesis.

Tao Wu1, Richard H Moore, Elizabeth A Rafferty, Daniel B Kopans.   

Abstract

Three algorithms for breast tomosynthesis reconstruction were compared in this paper, including (1) a back-projection (BP) algorithm (equivalent to the shift-and-add algorithm), (2) a Feldkamp filtered back-projection (FBP) algorithm, and (3) an iterative Maximum Likelihood (ML) algorithm. Our breast tomosynthesis system acquires 11 low-dose projections over a 50 degree angular range using an a-Si (CsI:Tl) flat-panel detector. The detector was stationary during the acquisition. Quality metrics such as signal difference to noise ratio (SDNR) and artifact spread function (ASF) were used for quantitative evaluation of tomosynthesis reconstructions. The results of the quantitative evaluation were in good agreement with the results of the qualitative assessment. In patient imaging, the superimposed breast tissues observed in two-dimensional (2D) mammograms were separated in tomosynthesis reconstructions by all three algorithms. It was shown in both phantom imaging and patient imaging that the BP algorithm provided the best SDNR for low-contrast masses but the conspicuity of the feature details was limited by interplane artifacts; the FBP algorithm provided the highest edge sharpness for microcalcifications but the quality of masses was poor; the information of both the masses and the microcalcifications were well restored with balanced quality by the ML algorithm, superior to the results from the other two algorithms.

Entities:  

Mesh:

Year:  2004        PMID: 15487747     DOI: 10.1118/1.1786692

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  81 in total

1.  A software-based x-ray scatter correction method for breast tomosynthesis.

Authors:  Steve Si Jia Feng; Ioannis Sechopoulos
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Computer-aided detection of clustered microcalcifications in digital breast tomosynthesis: a 3D approach.

Authors:  Berkman Sahiner; Heang-Ping Chan; Lubomir M Hadjiiski; Mark A Helvie; Jun Wei; Chuan Zhou; Yao Lu
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

3.  Intravenous pyelogram artefacts unique to digital tomosynthesis reconstruction.

Authors:  B K Rowberry; A Galea
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

4.  High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array.

Authors:  Xin Qian; Andrew Tucker; Emily Gidcumb; Jing Shan; Guang Yang; Xiomara Calderon-Colon; Shabana Sultana; Jianping Lu; Otto Zhou; Derrek Spronk; Frank Sprenger; Yiheng Zhang; Don Kennedy; Tom Farbizio; Zhenxue Jing
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

5.  Image quality of microcalcifications in digital breast tomosynthesis: effects of projection-view distributions.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Mitch Goodsitt; Paul L Carson; Lubomir Hadjiiski; Andrea Schmitz; Jeffrey W Eberhard; Bernhard E H Claus
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

6.  A constrained, total-variation minimization algorithm for low-intensity x-ray CT.

Authors:  Emil Y Sidky; Yuval Duchin; Xiaochuan Pan; Christer Ullberg
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

7.  A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems.

Authors:  Melanie Freed; Subok Park; Aldo Badano
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

8.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

9.  Refraction corrected transmission ultrasound computed tomography for application in breast imaging.

Authors:  Shengying Li; Marcel Jackowski; Donald P Dione; Trond Varslot; Lawrence H Staib; Klaus Mueller
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

10.  Comparison study of reconstruction algorithms for prototype digital breast tomosynthesis using various breast phantoms.

Authors:  Ye-seul Kim; Hye-suk Park; Haeng-Hwa Lee; Young-Wook Choi; Jae-Gu Choi; Hak Hee Kim; Hee-Joung Kim
Journal:  Radiol Med       Date:  2015-09-18       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.