Literature DB >> 15562466

4 T actively detunable transmit/receive transverse electromagnetic coil and 4-channel receive-only phased array for (1)H human brain studies.

Nikolai I Avdievich1, Hoby P Hetherington.   

Abstract

The design and construction of a 4 T transverse electromagnetic (TEM) transmit/receive head coil and a four-channel phased array receive-only RF system are described. To enable both high-resolution imaging of the entire brain and high-resolution spectroscopic imaging, active PIN diode decoupling was used in both the TEM resonator and each surface coil in the array. This configuration allows for both transmission and reception from the volume coil as well as reception from the phased array. The surface coils were decoupled by overlapping the coils and using preamplifier decoupling. Since at high frequencies construction of a lumped element matching quarter wavelength transformer, an important component of the preamplifier decoupling, becomes difficult, a transmission line approach was used. The system was tested and compared to a TEM volume transmit/receive head coil. A four- to sixfold improvement in signal-to-noise ratio from the sensitive volume of the array was achieved. (c) 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15562466     DOI: 10.1002/mrm.20264

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.

Authors:  Ralf Mekle; Wietske van der Zwaag; Andreas Joosten; Rolf Gruetter
Journal:  MAGMA       Date:  2008-01-10       Impact factor: 2.310

2.  Occipital levels of GABA are related to severe headaches in migraine.

Authors:  M E Bigal; H Hetherington; J Pan; A Tsang; B Grosberg; N Avdievich; B Friedman; R B Lipton
Journal:  Neurology       Date:  2008-05-27       Impact factor: 9.910

3.  Multiple-Input Multiple-Output (MIMO) MRI: Combining Parallel Excitation and Parallel Reception for Enhanced Imaging.

Authors:  Xianglun Mao; Nicole L Vike; Thomas M Talavage; Joseph V Rispoli; David J Love
Journal:  IEEE Trans Comput Imaging       Date:  2019-03-13

4.  Improved homogeneity of the transmit field by simultaneous transmission with phased array and volume coil.

Authors:  Nikolai I Avdievich; Sukhoon Oh; Hoby P Hetherington; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2010-08       Impact factor: 4.813

5.  A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T.

Authors:  Chunsheng Wang; Ye Li; Bing Wu; Duan Xu; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

6.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy.

Authors:  N I Avdievich; H P Hetherington
Journal:  J Magn Reson       Date:  2007-03-03       Impact factor: 2.229

7.  Actively Decoupled Transmit-Receive Coil-Pair for Mouse Brain MRI.

Authors:  Joel R Garbow; Charlie McIntosh; Mark S Conradi
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2008-10       Impact factor: 1.176

8.  Short echo spectroscopic imaging of the human brain at 7T using transceiver arrays.

Authors:  N I Avdievich; J W Pan; J M Baehring; D D Spencer; H P Hetherington
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

9.  7T head volume coils: improvements for rostral brain imaging.

Authors:  Nikolai I Avdievich; Hoby P Hetherington; Andrey M Kuznetsov; Jullie W Pan
Journal:  J Magn Reson Imaging       Date:  2009-02       Impact factor: 4.813

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.