Literature DB >> 7968443

High frequency volume coils for clinical NMR imaging and spectroscopy.

J T Vaughan1, H P Hetherington, J O Otu, J W Pan, G M Pohost.   

Abstract

A tuned transmission line resonator has been developed in theory and in practical design for the clinical NMR volume coil application at 4.1 tesla. The distributed circuit transmission line resonator was designed for high frequency, large conductive volume applications where conventional lumped element coil designs perform less efficiently. The resonator design has made use of a resonant coaxial cavity, which could be variably tuned to the Larmor frequency of interest by tunable transmission line elements. Large head- and body-sized volumes, high efficiencies, and broad tuning ranges have been shown to be characteristic of the transmission line resonator to frequencies of 500 MHz. The B1 homogeneity of the resonator has been demonstrated to be a function of the electromagnetic properties of the load itself. By numerically solving Maxwell's equations for the fully time-dependent B1 field, coil homogeneity was predicted with finite-element models of anatomic structure, and inhomogeneities corrected for. A how-to exposition of coil design and construction has been included. Simple methods of quadrature driving and double tuning the transmission line resonator have also been presented. Human head images obtained with a tuned transmission line resonator at 175 MHz have clearly demonstrated uncompromised high field advantages of signal-to-noise and spatial resolution.

Entities:  

Mesh:

Year:  1994        PMID: 7968443     DOI: 10.1002/mrm.1910320209

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  76 in total

1.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Rapid and effective correction of RF inhomogeneity for high field magnetic resonance imaging.

Authors:  M S Cohen; R M DuBois; M M Zeineh
Journal:  Hum Brain Mapp       Date:  2000-08       Impact factor: 5.038

3.  Progress in high field MRI at the University of Florida.

Authors:  B Beck; D H Plant; S C Grant; P E Thelwall; X Silver; T H Mareci; H Benveniste; M Smith; C Collins; S Crozier; S J Blackband
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

4.  SWIFT detection of SPIO-labeled stem cells grafted in the myocardium.

Authors:  Rong Zhou; Djaudat Idiyatullin; Steen Moeller; Curt Corum; Hualei Zhang; Hui Qiao; Jia Zhong; Michael Garwood
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

5.  MDEFT imaging of the human brain at 8 T.

Authors:  D G Norris; A Kangarlu; C Schwarzbauer; A M Abduljalil; G Christoforidis; P M Robitaille
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

6.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

7.  4T split TEM volume head and knee coils for improved sensitivity and patient accessibility.

Authors:  Nikolai I Avdievich; Ken Bradshaw; Jing-Huei Lee; Andrey M Kuznetsov; Hoby P Hetherington
Journal:  J Magn Reson       Date:  2007-05-16       Impact factor: 2.229

8.  SAR and temperature: simulations and comparison to regulatory limits for MRI.

Authors:  Zhangwei Wang; James C Lin; Weihua Mao; Wanzhan Liu; Michael B Smith; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

9.  Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.

Authors:  Ralf Mekle; Wietske van der Zwaag; Andreas Joosten; Rolf Gruetter
Journal:  MAGMA       Date:  2008-01-10       Impact factor: 2.310

Review 10.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

View more