Literature DB >> 19142632

Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress.

Patrick T Liu1, William P Pavlicek, Mary B Peter, Mark J Spangehl, Catherine C Roberts, Robert G Paden.   

Abstract

INTRODUCTION: Despite recent advances in CT technology, metal orthopedic implants continue to cause significant artifacts on many CT exams, often obscuring diagnostic information. We performed this prospective study to evaluate the effectiveness of an experimental metal artifact reduction (MAR) image reconstruction program for CT.
MATERIALS AND METHODS: We examined image quality on CT exams performed in patients with hip arthroplasties as well as other types of implanted metal orthopedic devices. The exam raw data were reconstructed using two different methods, the standard filtered backprojection (FBP) program and the MAR program. Images were evaluated for quality of the metal-cement-bone interfaces, trabeculae < or = 1 cm from the metal, trabeculae 5 cm apart from the metal, streak artifact, and overall soft tissue detail. The Wilcoxon Rank Sum test was used to compare the image scores from the large and small prostheses. Interobserver agreement was calculated.
RESULTS: When all patients were grouped together, the MAR images showed mild to moderate improvement over the FBP images. However, when the cases were divided by implant size, the MAR images consistently received higher image quality scores than the FBP images for large metal implants (total hip prostheses). For small metal implants (screws, plates, staples), conversely, the MAR images received lower image quality scores than the FBP images due to blurring artifact. The difference of image scores for the large and small implants was significant (p = 0.002). Interobserver agreement was found to be high for all measures of image quality (k > 0.9).
CONCLUSION: The experimental MAR reconstruction algorithm significantly improved CT image quality for patients with large metal implants. However, the MAR algorithm introduced blurring artifact that reduced image quality with small metal implants.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19142632     DOI: 10.1007/s00256-008-0630-5

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  13 in total

1.  Complications of total hip arthroplasty: MR imaging-initial experience.

Authors:  L M White; J K Kim; M Mehta; N Merchant; M E Schweitzer; W B Morrison; C R Hutchison; A E Gross
Journal:  Radiology       Date:  2000-04       Impact factor: 11.105

2.  Fast iterative algorithm for metal artifact reduction in X-ray CT.

Authors:  G Wang; T Frei; M W Vannier
Journal:  Acad Radiol       Date:  2000-08       Impact factor: 3.173

Review 3.  Multichannel CT Imaging of Orthopedic Hardware and Implants.

Authors:  Kenneth A Buckwalter; J Andrew Parr; Robert H Choplin; William N Capello
Journal:  Semin Musculoskelet Radiol       Date:  2006-03       Impact factor: 1.777

4.  Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.

Authors:  D D Robertson; J Yuan; G Wang; M W Vannier
Journal:  J Comput Assist Tomogr       Date:  1997 Mar-Apr       Impact factor: 1.826

Review 5.  Multichannel CT: evaluating the spine in postoperative patients with orthopedic hardware.

Authors:  Annette C Douglas-Akinwande; Kenneth A Buckwalter; Jonas Rydberg; James L Rankin; Robert H Choplin
Journal:  Radiographics       Date:  2006-10       Impact factor: 5.333

6.  Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering.

Authors:  Matthieu Bal; Lothar Spies
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

7.  CT of metal implants: reduction of artifacts using an extended CT scale technique.

Authors:  T M Link; W Berning; S Scherf; U Joosten; A Joist; K Engelke; H E Daldrup-Link
Journal:  J Comput Assist Tomogr       Date:  2000 Jan-Feb       Impact factor: 1.826

8.  MRI as a problem-solving tool in unexplained failed total hip replacement following conventional assessment.

Authors:  Ciaran Johnston; Jennifer Kerr; Stephanie Ford; John O'byrne; Stephen Eustace
Journal:  Skeletal Radiol       Date:  2007-07-06       Impact factor: 2.199

9.  A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement.

Authors:  Andreas H Mahnken; Rainer Raupach; Joachim E Wildberger; Bettina Jung; Nicole Heussen; Thomas G Flohr; Rolf W Günther; Stefan Schaller
Journal:  Invest Radiol       Date:  2003-12       Impact factor: 6.016

10.  Diagnosis of peri-prosthetic infection at the hip using triple-phase bone scintigraphy.

Authors:  S Nagoya; M Kaya; M Sasaki; K Tateda; T Yamashita
Journal:  J Bone Joint Surg Br       Date:  2008-02
View more
  23 in total

1.  Voxel classification and graph cuts for automated segmentation of pathological periprosthetic hip anatomy.

Authors:  Daniel F Malan; Charl P Botha; Edward R Valstar
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-01-21       Impact factor: 2.924

2.  Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.

Authors:  W Wuest; M S May; M Brand; N Bayerl; A Krauss; M Uder; M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

3.  Total ankle arthroplasty: optimizing computed tomography imaging protocol.

Authors:  Ia Kohonen; Helka Koivu; Tero Vahlberg; Heli Larjava; Kimmo Mattila
Journal:  Skeletal Radiol       Date:  2013-08-03       Impact factor: 2.199

4.  Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling-improved image quality by iterative metal artifact reduction.

Authors:  Georg Bier; Malte Niklas Bongers; Johann-Martin Hempel; Anja Örgel; Till-Karsten Hauser; Ulrike Ernemann; Florian Hennersdorf
Journal:  Neuroradiology       Date:  2017-06-03       Impact factor: 2.804

5.  Iterative algorithms for metal artifact reduction in children with orthopedic prostheses: preliminary results.

Authors:  Seema Toso; Meryle Laurent; Elise Dupuis Lozeron; Pauline Brindel; Marirosa Cristallo Lacalamita; Sylviane Hanquinet
Journal:  Pediatr Radiol       Date:  2018-07-28

6.  Measuring femoral lesions despite CT metal artefacts: a cadaveric study.

Authors:  Daniel F Malan; Charl P Botha; Gert Kraaij; Raoul M S Joemai; Huub J L van der Heide; Rob G H H Nelissen; Edward R Valstar
Journal:  Skeletal Radiol       Date:  2011-07-06       Impact factor: 2.199

7.  Artifact level produced by different femoral head prostheses in CT imaging: diamond coated silicon nitride as total hip replacement material.

Authors:  Simone P Rodrigues; José M Paiva; Silvia De Francesco; Margarida I Amaral; Filipe J Oliveira; Rui F Silva
Journal:  J Mater Sci Mater Med       Date:  2012-10-07       Impact factor: 3.896

8.  Frequency split metal artefact reduction in pelvic computed tomography.

Authors:  M M Lell; E Meyer; M Schmid; R Raupach; M S May; M Uder; M Kachelriess
Journal:  Eur Radiol       Date:  2013-03-22       Impact factor: 5.315

9.  Effect of brightness in the evaluation of lumbar pedicular screws position: clinical study.

Authors:  L M Romero-Muñoz; M Alfonso; C Villas; J L Zubieta
Journal:  Musculoskelet Surg       Date:  2013-04-05

10.  CT provides precise size assessment of implanted titanium alloy pedicle screws.

Authors:  Michael J Elliott; Joseph B Slakey
Journal:  Clin Orthop Relat Res       Date:  2014-02-11       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.