Literature DB >> 23558728

Effect of brightness in the evaluation of lumbar pedicular screws position: clinical study.

L M Romero-Muñoz1, M Alfonso, C Villas, J L Zubieta.   

Abstract

Artifact may lead to confusion when evaluating postoperative CT scans of lumbar pedicle screws. The aim of our study was to develop a specific metal artifact reduction image protocol, in order to reduce metal artifact caused by titanium pedicular screw in patients undergoing lumbar pathology by lumbar fusion. Therefore, the reduction in metal artifacts in lumbar pedicle screws allows surgeons to do an accurate diagnosis of the exact placement of inserted pedicle screws, minimizes false reexploration, and maximizes proper and prompt treatment of misplaced screw. In a first step, we performed a retrospective study of 103 titanium alloy pedicle screws in patients undergoing a lumbar instrumented fusion for treatment for degenerative disease. CT scan was performed postoperatively evaluating the possible overdimension caused by artifact. In a second step, a prospective study was performed using a 64-slice multidetector-row computed tomography (MDCT) in 104 titanium alloy pedicle screws in patients undergoing a lumbar instrumented fusion for treatment for degenerative disease. Our results show that on the group of sequential CT scan, mean overdimension (on each side) due to brightness was 1.045 mm (SD 0.45). On the group of 64-slice multichannel CT, mean overdimension (on each side) due to brightness was 0.005 mm at the proximal part of the screw and 0.025 mm at the distal part of the screw. The results observed suggest that beam-hardening artifacts caused by the screw on CT after lumbar fusion are dramatically reduced by using specific metal artifact reduction image protocol in a 64-slice MDCT.

Entities:  

Mesh:

Year:  2013        PMID: 23558728     DOI: 10.1007/s12306-013-0248-1

Source DB:  PubMed          Journal:  Musculoskelet Surg        ISSN: 2035-5114


  24 in total

1.  Musculoskeletal imaging with multislice CT.

Authors:  K A Buckwalter; J Rydberg; K K Kopecky; K Crow; E L Yang
Journal:  AJR Am J Roentgenol       Date:  2001-04       Impact factor: 3.959

2.  Evaluation of pedicle screw position on computerized tomography scans. Technical note.

Authors:  Jin Sup Yeom; Moon Sang Chung; Choon-Ki Lee; Yeongho Kim; Namkug Kim; Jae Bum Lee
Journal:  J Neurosurg       Date:  2003-01       Impact factor: 5.115

3.  Posterior spinal fusion in adolescent idiopathic scoliosis with or without intraoperative cell salvage system: a retrospective comparison.

Authors:  Omer Ersen; Safak Ekıncı; Serkan Bılgıc; Ozkan Kose; Erbil Oguz; Ali Sehırlıoglu
Journal:  Musculoskelet Surg       Date:  2012-05-27

4.  Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis.

Authors:  O Schwarzenbach; U Berlemann; B Jost; H Visarius; E Arm; F Langlotz; L P Nolte; C Ozdoba
Journal:  Spine (Phila Pa 1976)       Date:  1997-02-15       Impact factor: 3.468

5.  Lumbosacral arthrodesis using pedicular screws and ringed rods.

Authors:  J L Beguiristain; C Villas; R Preite; R Martinez; R H Barrios
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

6.  CT scans through metal scanning technique versus hardware composition.

Authors:  N Haramati; R B Staron; K Mazel-Sperling; K Freeman; E L Nickoloff; C Barax; F Feldman
Journal:  Comput Med Imaging Graph       Date:  1994 Nov-Dec       Impact factor: 4.790

7.  CT of metal implants: reduction of artifacts using an extended CT scale technique.

Authors:  T M Link; W Berning; S Scherf; U Joosten; A Joist; K Engelke; H E Daldrup-Link
Journal:  J Comput Assist Tomogr       Date:  2000 Jan-Feb       Impact factor: 1.826

8.  Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine.

Authors:  J U Yoo; A Ghanayem; C Petersilge; J Lewin
Journal:  Spine (Phila Pa 1976)       Date:  1997-11-15       Impact factor: 3.468

9.  Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results.

Authors:  Lifeng Yu; Hua Li; Jan Mueller; James M Kofler; Xin Liu; Andrew N Primak; Joel G Fletcher; Luis S Guimaraes; Thanila Macedo; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2009-11       Impact factor: 6.016

10.  Imaging assessment of lumbar pedicle screw placement: sensitivity and specificity of plain radiographs and computer axial tomography.

Authors:  Dahari Brooks; Mark Eskander; Steve Balsis; Nat Ordway; Patrick Connolly
Journal:  Spine (Phila Pa 1976)       Date:  2007-06-01       Impact factor: 3.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.