Literature DB >> 16514583

Multichannel CT Imaging of Orthopedic Hardware and Implants.

Kenneth A Buckwalter1, J Andrew Parr, Robert H Choplin, William N Capello.   

Abstract

The introduction of multichannel CT scanners provides both radiologists and surgeons with a new tool to image patients with orthopedic hardware. The key parameters that have made it possible to image the implants and the surrounding bone with multichannel CT are the higher available technical factors (kVp and mAs) coupled with the ability to acquire thin slices over a large scan region. These properties make it possible to produce high-quality multiplanar reformations that facilitate visualization of the orthopedic device and the surrounding bone. An important consideration for multichannel CT imaging of hardware is the reduction of cone beam artifacts caused by the geometry of multichannel CT scanners. This artifact is reduced by using a narrower x-ray beam collimation and a low pitch setting. This article discusses CT scan parameters and image postprocessing used at our institution and illustrates common clinical problems encountered when imaging implanted orthopedic devices. These include fracture healing, loosening of joint prostheses, evaluation of particle disease, and the use of CT for preoperative planning in revision arthroplasty.

Entities:  

Mesh:

Year:  2006        PMID: 16514583     DOI: 10.1055/s-2006-934219

Source DB:  PubMed          Journal:  Semin Musculoskelet Radiol        ISSN: 1089-7860            Impact factor:   1.777


  18 in total

1.  Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels.

Authors:  R Guggenberger; S Winklhofer; G Osterhoff; G A Wanner; M Fortunati; G Andreisek; H Alkadhi; P Stolzmann
Journal:  Eur Radiol       Date:  2012-05-30       Impact factor: 5.315

2.  Total ankle arthroplasty: optimizing computed tomography imaging protocol.

Authors:  Ia Kohonen; Helka Koivu; Tero Vahlberg; Heli Larjava; Kimmo Mattila
Journal:  Skeletal Radiol       Date:  2013-08-03       Impact factor: 2.199

3.  CT evaluation of total hip arthroplasty complication: dissociation of acetabular component.

Authors:  Eric A Bogner; Carolyn M Sofka
Journal:  HSS J       Date:  2007-02

4.  Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

Authors:  Wei Zhou; David J Bartlett; Felix E Diehn; Katrina N Glazebrook; Amy L Kotsenas; Rickey E Carter; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2019-04       Impact factor: 6.016

5.  Value of monoenergetic dual-energy CT (DECT) for artefact reduction from metallic orthopedic implants in post-mortem studies.

Authors:  Laura Filograna; Nicola Magarelli; Antonio Leone; Roman Guggenberger; Sebastian Winklhofer; Michael John Thali; Lorenzo Bonomo
Journal:  Skeletal Radiol       Date:  2015-05-12       Impact factor: 2.199

Review 6.  What can be seen after rotator cuff repair: a brief review of diagnostic imaging findings.

Authors:  A Barile; F Bruno; S Mariani; F Arrigoni; A Reginelli; M De Filippo; M Zappia; A Splendiani; E Di Cesare; C Masciocchi
Journal:  Musculoskelet Surg       Date:  2017-02-13

7.  Performances of low-dose dual-energy CT in reducing artifacts from implanted metallic orthopedic devices.

Authors:  Laura Filograna; Nicola Magarelli; Antonio Leone; Chiara de Waure; Giovanna Elisa Calabrò; Tim Finkenstaedt; Michael John Thali; Lorenzo Bonomo
Journal:  Skeletal Radiol       Date:  2016-03-31       Impact factor: 2.199

8.  Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms.

Authors:  Nils Große Hokamp; V Neuhaus; N Abdullayev; K Laukamp; S Lennartz; A Mpotsaris; J Borggrefe
Journal:  Skeletal Radiol       Date:  2017-09-21       Impact factor: 2.199

9.  Quantification of metal artifacts in computed tomography: methodological considerations.

Authors:  Nils Große Hokamp; Brendan Eck; Florian Siedek; Daniel Pinto Dos Santos; Jasmin A Holz; David Maintz; Stefan Haneder
Journal:  Quant Imaging Med Surg       Date:  2020-05

10.  Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress.

Authors:  Patrick T Liu; William P Pavlicek; Mary B Peter; Mark J Spangehl; Catherine C Roberts; Robert G Paden
Journal:  Skeletal Radiol       Date:  2009-01-14       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.