Literature DB >> 23053807

Artifact level produced by different femoral head prostheses in CT imaging: diamond coated silicon nitride as total hip replacement material.

Simone P Rodrigues1, José M Paiva, Silvia De Francesco, Margarida I Amaral, Filipe J Oliveira, Rui F Silva.   

Abstract

Commercial femoral head prostheses (cobalt-chromium alloy, yttria partially stabilized zirconia (Y-PSZ) and alumina) and new silicon nitride ceramic ones (nanocrystalline diamond coated and uncoated) were compared in terms of artifact level production by computed tomography (CT). Pelvis examination by CT allows the correct diagnosis of some pathologies (e.g. prostate and colon cancer) and the evaluation of the prosthesis-bone interface in post-operative joint surgery. Artifact quantification is rarely seen in literature despite having a great potential to grade biomaterials according to their imaging properties. Materials' characteristics (density and effective atomic number), size and geometry of the prostheses can cause more or less artifact. A quantification procedure based on the calculation of four statistical parameters for the Hounsfield pixel values (mean, standard deviation, mean squared error and worst case error) is presented. CT sequential and helical scanning modes were performed. Results prove the artifact reproducibility and indicate that the cobalt-chromium and Y-PSZ are the most artifact-inducing materials, while alumina and silicon nitride (diamond coated and uncoated) ceramic ones present a low level of artifact. Considering the excellent biocompatibility and biotribological behaviour reported in earlier works, combined with the high medical imaging quality here assessed, diamond coated silicon nitride ceramics are arising as new materials for joint replacement.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23053807     DOI: 10.1007/s10856-012-4778-0

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  16 in total

1.  Automatic measurement of polyethylene modification in metal-backed artificial hip joints using three-dimensional CT.

Authors:  Shigeru Mitsuhashi; Yoshitada Harada; Noriyuki Yanagawa; Koya Kamikawa; Hiroshi Kitahara; Hideshige Moriya
Journal:  J Orthop Sci       Date:  2004       Impact factor: 1.601

2.  Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale.

Authors:  C Coolens; P J Childs
Journal:  Phys Med Biol       Date:  2003-06-07       Impact factor: 3.609

3.  An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies.

Authors:  Mehran Yazdi; Mehran Yazdia; Luc Gingras; Luc Beaulieu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-07-15       Impact factor: 7.038

Review 4.  Biomaterials in orthopaedics.

Authors:  M Navarro; A Michiardi; O Castaño; J A Planell
Journal:  J R Soc Interface       Date:  2008-10-06       Impact factor: 4.118

5.  Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction.

Authors:  D D Robertson; J Yuan; G Wang; M W Vannier
Journal:  J Comput Assist Tomogr       Date:  1997 Mar-Apr       Impact factor: 1.826

Review 6.  What's next? Alternative materials for articulation in total joint replacement.

Authors:  R Sonntag; J Reinders; J P Kretzer
Journal:  Acta Biomater       Date:  2012-03-23       Impact factor: 8.947

7.  The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacement.

Authors:  M Aubin; O Morin; J Chen; A Gillis; B Pickett; J F Aubry; C Akazawa; J Speight; M Roach; J Pouliot
Journal:  Br J Radiol       Date:  2006-08-17       Impact factor: 3.039

8.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

9.  Comparative investigation of the biocompatibility of various silicon nitride ceramic qualities in vitro.

Authors:  A Neumann; T Reske; M Held; K Jahnke; C Ragoss; H R Maier
Journal:  J Mater Sci Mater Med       Date:  2004-10       Impact factor: 3.896

10.  Fabrication and testing of silicon nitride bearings in total hip arthroplasty: winner of the 2007 "HAP" PAUL Award.

Authors:  B Sonny Bal; Ashok Khandkar; R Lakshminarayanan; Ian Clarke; Aaron A Hoffman; Mohamed N Rahaman
Journal:  J Arthroplasty       Date:  2008-04-28       Impact factor: 4.757

View more
  1 in total

Review 1.  Diamond thin films: giving biomedical applications a new shine.

Authors:  P A Nistor; P W May
Journal:  J R Soc Interface       Date:  2017-09       Impact factor: 4.118

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.