The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy.

Magdalena Bazalova1, Edward E Graves.   

Abstract

PURPOSE: The aim of this work was to evaluate the effect of tissue segmentation on the accuracy of Monte Carlo (MC) dose calculations for kilovoltage radiation therapy, which are commonly used in preclinical radiotherapy studies and are also being revisited as a clinical treatment modality. The feasibility of tissue segmentation routinely done on the basis of differences in tissue mass densities was studied and a new segmentation scheme based on differences in effective atomic numbers was developed.
METHODS: MC dose calculations in a cylindrical mouse phantom with small cylindrical inhomogeneities consisting of 34 ICRU-44 tissues were performed using the EGSnrc/BEAMnrc and DOSXYZnrc codes. The dose to tissue was calculated for five different kilovoltage beams currently used in small animal radiotherapy: a microCT 120 kV beam, two 225 kV beams filtered with either 4 mm of Al or 0.5 mm of Cu, a heavily filtered 320 kV beam, and a 192Ir beam. The mean doses to the 34 ICRU-44 tissues as a function of tissue mass density and effective atomic number and beam energy were studied. A treatment plan for an orthotopic lung tumor model was created, and the dose distribution was calculated for three tissue segmentation schemes using 4, 8, and 39 tissue bins to assess the significance of the simulation results for kilovoltage radiotherapy.
RESULTS: In our model, incorrect assignment of adipose tissue to muscle caused dose calculation differences of 27%, 13%, and 7% for the 120 kV beam and the 225 kV beams filtered with 4 mm Al and 0.5 mm Cu, respectively. For the heavily filtered 320 kV beam and a 192Ir source, potential dose calculation differences due to tissue mis-assignment were below 4%. There was no clear relationship between the dose to tissue and its mass density for x-ray beams generated by tube potentials equal or less than 225 kV. A second order polynomial fit approximated well the absorbed dose to tissue as a function of effective atomic number for these beams. In the mouse study, the 120 kV beam dose to bone was overestimated by 100% and underestimated by 10% for the 4 and 8-tissue segmentation schemes compared to the 39-tissue segmentation scheme, respectively. Dose to adipose tissue was overestimated by 30% and underestimated by 10%, respectively. In general, organ at risk (OAR) doses were overestimated in the 4-tissue and the 8-tissue segmentation schemes compared to the 39-tissue segmentation.
CONCLUSIONS: Tissue segmentation was shown to be a key parameter for dose calculations with kilovoltage beams used in small animal radiotherapy when an x-ray tube with a potential < or = 225 kV is used as a source. A new tissue segmentation scheme with 39 tissues based on effective number differences derived from mass density differences has been implemented.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21815377      PMCID: PMC3125081          DOI: 10.1118/1.3589138

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions.

Authors:  W Schneider; T Bortfeld; W Schlegel
Journal:  Phys Med Biol       Date:  2000-02       Impact factor: 3.609

2.  The effect of patient inhomogeneities in oesophageal 192Ir HDR brachytherapy: a Monte Carlo and analytical dosimetry study.

Authors:  G Anagnostopoulos; D Baltas; E Pantelis; P Papagiannis; L Sakelliou
Journal:  Phys Med Biol       Date:  2004-06-21       Impact factor: 3.609

3.  Dosimetric variation due to the photon beam energy in the small-animal irradiation: a Monte Carlo study.

Authors:  James C L Chow; Michael K K Leung; Patricia E Lindsay; David A Jaffray
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

4.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units.

Authors:  D W Rogers; B A Faddegon; G X Ding; C M Ma; J We; T R Mackie
Journal:  Med Phys       Date:  1995-05       Impact factor: 4.071

5.  The calibration of CT Hounsfield units for radiotherapy treatment planning.

Authors:  U Schneider; E Pedroni; A Lomax
Journal:  Phys Med Biol       Date:  1996-01       Impact factor: 3.609

6.  3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC).

Authors:  I Kawrakow; M Fippel; K Friedrich
Journal:  Med Phys       Date:  1996-04       Impact factor: 4.071

7.  Neutron or photon irradiation for prostate tumors: enhancement of cytokine therapy in a metastatic tumor model.

Authors:  G G Hillman; R L Maughan; D J Grignon; M Yudelev; J Rubio; S Tekyi-Mensah; A Layer; M Che; J D Forman
Journal:  Clin Cancer Res       Date:  2001-01       Impact factor: 12.531

8.  Calcium, iron, copper, boron, collagen, and density changes in bone with aging in C57BL/6J male mice.

Authors:  H R Massie; V R Aiello; M E Shumway; T Armstrong
Journal:  Exp Gerontol       Date:  1990       Impact factor: 4.032

9.  Bone fragility induced by X-ray irradiation in relation to cortical bone-mineral content.

Authors:  M M Nyaruba; I Yamamoto; H Kimura; R Morita
Journal:  Acta Radiol       Date:  1998-01       Impact factor: 1.990

10.  Partial volume rat lung irradiation: an evaluation of early DNA damage.

Authors:  M A Khan; R P Hill; J Van Dyk
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-01-15       Impact factor: 7.038

View more
  16 in total

1.  Design and development of a new micro-beam treatment planning system: effectiveness of algorithms of optimization and dose calculations and potential of micro-beam treatment.

Authors:  Hidenobu Tachibana; Hiroyuki Kojima; Noritaka Yusa; Satoshi Miyajima; Akihisa Tsuda; Takashi Yamashita
Journal:  Radiol Phys Technol       Date:  2012-04-29

2.  Murine vs human tissue compositions: implications of using human tissue compositions for photon energy absorption in mice.

Authors:  Lotte Ejr Schyns; Daniëlle Bp Eekers; Brent van der Heyden; Isabel P Almeida; Ana Vaniqui; Frank Verhaegen
Journal:  Br J Radiol       Date:  2018-11-30       Impact factor: 3.039

3.  Scattered Dose Calculations and Measurements in a Life-Like Mouse Phantom.

Authors:  David Welch; Leah Turner; Michael Speiser; Gerhard Randers-Pehrson; David J Brenner
Journal:  Radiat Res       Date:  2017-01-31       Impact factor: 2.841

Review 4.  Optimizing dual energy cone beam CT protocols for preclinical imaging and radiation research.

Authors:  Lotte E J R Schyns; Isabel P Almeida; Stefan J van Hoof; Benedicte Descamps; Christian Vanhove; Guillaume Landry; Patrick V Granton; Frank Verhaegen
Journal:  Br J Radiol       Date:  2016-11-02       Impact factor: 3.039

5.  Modality comparison for small animal radiotherapy: a simulation study.

Authors:  Magdalena Bazalova; Geoff Nelson; John M Noll; Edward E Graves
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

6.  Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies.

Authors:  D Welch; A D Harken; G Randers-Pehrson; D J Brenner
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

7.  Multi-institutional MicroCT image comparison of image-guided small animal irradiators.

Authors:  Chris D Johnstone; Patricia Lindsay; Edward E Graves; Eugene Wong; Jessica R Perez; Yannick Poirier; Youssef Ben-Bouchta; Thilakshan Kanesalingam; Haijian Chen; Ashley E Rubinstein; Ke Sheng; Magdalena Bazalova-Carter
Journal:  Phys Med Biol       Date:  2017-06-26       Impact factor: 3.609

8.  Significance of the spectral correction of photon counting detector response in material classification from spectral x-ray CT.

Authors:  Doniyor Jumanazarov; Jakeoung Koo; Henning F Poulsen; Ulrik L Olsen; Mihai Iovea
Journal:  J Med Imaging (Bellingham)       Date:  2022-06-30

9.  Monte Carlo model of the scanning beam digital x-ray (SBDX) source.

Authors:  M Bazalova; M D Weil; B Wilfley; E E Graves
Journal:  Phys Med Biol       Date:  2012-10-24       Impact factor: 3.609

10.  MRI-Only Based Radiotherapy Treatment Planning for the Rat Brain on a Small Animal Radiation Research Platform (SARRP).

Authors:  Shandra Gutierrez; Benedicte Descamps; Christian Vanhove
Journal:  PLoS One       Date:  2015-12-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.