Literature DB >> 8923704

Ultrasound backscatter microscope analysis of mouse melanoma progression.

D H Turnbull1, J A Ramsay, G S Shivji, T S Bloomfield, L From, D N Sauder, F S Foster.   

Abstract

The incidence and mortality rate of cutaneous melanoma continue to increase throughout the world, making the study of melanoma biology an important area of current research. While recent breakthroughs in transgenic mouse technology have led to promising mouse skin models of melanoma, there is presently no technique available for quantitatively studying subsurface melanoma progression, in vivo. We demonstrate the first application of an imaging method called ultrasound backscatter microscopy (UBM) for imaging early murine melanomas with spatial resolution of 30 microns axial and 60 microns lateral. Murine B16 F10 melanomas have been imaged from their earliest detection, over several days, until they are 2 to 5 mm in diameter. Melanoma dimensions measured by UBM were found to be in excellent agreement with those determined histopathologically on the excised tumours. The relative rms errors in UBM-determined melanoma height and width were found to be 8.7% and 4.2%, respectively. The mean rate of increase in tumour height of early murine melanoma was found to be 0.37 +/- 0.06 mm/day. Computer-generated volumetric renderings of melanomas have been produced from three-dimensional image data, allowing quantitative comparisons of tumour volumes to be made. Using a priori assumptions of ellipsoid tumour shape, the relative error in UBM-determined volume was shown to be less than 17%. These results should be of considerable interest to investigators studying melanoma biology using mouse skin models, and have implications in the use of high frequency ultrasound imaging for the clinical assessment of cutaneous melanoma.

Entities:  

Mesh:

Year:  1996        PMID: 8923704     DOI: 10.1016/0301-5629(96)00107-x

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  11 in total

1.  Ultrasonic characterization of porcine liver tissue at frequency between 25 to 55 MHz.

Authors:  Xiao-Zhou Liu; Xiu-Fen Gong; Dong Zhang; Shi-Gong Ye; Bing Rui
Journal:  World J Gastroenterol       Date:  2006-04-14       Impact factor: 5.742

Review 2.  Gene expression and gene therapy imaging.

Authors:  Claire Rome; Franck Couillaud; Chrit T W Moonen
Journal:  Eur Radiol       Date:  2006-09-12       Impact factor: 5.315

3.  High-resolution, high-contrast ultrasound imaging using a prototype dual-frequency transducer: in vitro and in vivo studies.

Authors:  Ryan Gessner; Marc Lukacs; Mike Lee; Emmanuel Cherin; F Stuart Foster; Paul A Dayton
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-08       Impact factor: 2.725

4.  Influence of Domain Size on the Scaling Effects in Pb(Mg1/3Nb2/3)O3-PbTiO3 Ferroelectric Crystals.

Authors:  Dabin Lin; Hyeong Jae Lee; Shujun Zhang; Fei Li; Zhenrong Li; Zhuo Xu; Thomas R Shrout
Journal:  Scr Mater       Date:  2011-06-01       Impact factor: 5.611

5.  3D-printed Wash Station with Integrated Anesthesia Delivery Manifold for High-throughput Depilation of Laboratory Mice.

Authors:  Lucas D Liepert; Jordan Raphel; Victoria L Smith; Nicole Reilly; Sarah Khan; Christopher Dethlefs; Sarah Chapman; Satish Adusumilli; W Matthew Leevy
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-12-07       Impact factor: 1.232

6.  Image-guided small animal radiation research platform: calibration of treatment beam alignment.

Authors:  Mohammad Matinfar; Eric Ford; Iulian Iordachita; John Wong; Peter Kazanzides
Journal:  Phys Med Biol       Date:  2009-01-14       Impact factor: 3.609

7.  Characterization of a broadband all-optical ultrasound transducer-from optical and acoustical properties to imaging.

Authors:  Yang Hou; Jin-Sung Kim; Sheng-Wen Huang; S Ashkenazi; L J Guo; M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-08       Impact factor: 2.725

8.  A post-beamforming 2-D pseudoinverse filter for coarsely sampled ultrasound arrays.

Authors:  Yayun Wan; Emad S Ebbini
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-09       Impact factor: 2.725

Review 9.  Ultrasound biomicroscopy in small animal research: applications in molecular and preclinical imaging.

Authors:  A Greco; M Mancini; S Gargiulo; M Gramanzini; P P Claudio; A Brunetti; M Salvatore
Journal:  J Biomed Biotechnol       Date:  2011-10-25

10.  Antitumor effects of combining docetaxel (taxotere) with the antivascular action of ultrasound stimulated microbubbles.

Authors:  David E Goertz; Margarita Todorova; Omid Mortazavi; Vlad Agache; Branson Chen; Raffi Karshafian; Kullervo Hynynen
Journal:  PLoS One       Date:  2012-12-20       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.