Literature DB >> 19034594

Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Jörn Zwingmann1, Gerhard Konrad, Elmar Kotter, Norbert P Südkamp, Michael Oberst.   

Abstract

UNLABELLED: Insertion of percutaneous iliosacral screws with fluoroscopic guidance is associated with a relatively high screw malposition rate and long radiation exposure. We asked whether radiation exposure was reduced and screw position improved in patients having percutaneous iliosacral screw insertion using computer-assisted navigation compared with patients having conventional fluoroscopic screw placement. We inserted 26 screws in 24 patients using the navigation system and 35 screws in 32 patients using the conventional fluoroscopic technique. Two subgroups were analyzed, one in which only one iliosacral screw was placed and another with additional use of an external fixator. We determined screw positions by computed tomography and compared operation time, radiation exposure, and screw position. We observed no difference in operative times. Radiation exposure was reduced for the patients and operating room personnel with computer assistance. The postoperative computed tomography scan showed better screw position and fewer malpositioned screws in the three-dimensional navigated groups. Computer navigation reduced malposition rate and radiation exposure. LEVEL OF EVIDENCE: Level II, therapeutic study.

Entities:  

Mesh:

Year:  2008        PMID: 19034594      PMCID: PMC2690740          DOI: 10.1007/s11999-008-0632-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  [Navigation assisted by image conversion. An experimental study on pelvic screw fixation].

Authors:  U Stöckle; B König; R Hofstetter; L P Nolte; N P Haas
Journal:  Unfallchirurg       Date:  2001-03       Impact factor: 1.000

2.  Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study.

Authors:  E F Barrick; J W O'Mara; H E Lane
Journal:  Comput Aided Surg       Date:  1998

3.  Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion.

Authors:  Y R Rampersaud; K T Foley; A C Shen; S Williams; M Solomito
Journal:  Spine (Phila Pa 1976)       Date:  2000-10-15       Impact factor: 3.468

4.  [Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery].

Authors:  U Stöckle; B König; A Schäffler; T Zschernack; N P Haas
Journal:  Unfallchirurg       Date:  2006-01       Impact factor: 1.000

5.  An evaluation of image-guided technologies in the placement of percutaneous iliosacral screws.

Authors:  Harvey E Smith; Philip S Yuan; Rick Sasso; Steven Papadopolous; Alexander R Vaccaro
Journal:  Spine (Phila Pa 1976)       Date:  2006-01-15       Impact factor: 3.468

6.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

Authors:  D Briem; J Windolf; J M Rueger
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

7.  The accuracy of computer-assisted percutaneous iliosacral screw placement.

Authors:  Adrian C Day; Philip M Stott; Richard A Boden
Journal:  Clin Orthop Relat Res       Date:  2007-10       Impact factor: 4.176

8.  Percutaneous iliosacral screw placement using image guided techniques.

Authors:  J Tonetti; L Carrat; S Lavalleé; L Pittet; P Merloz; J P Chirossel
Journal:  Clin Orthop Relat Res       Date:  1998-09       Impact factor: 4.176

9.  Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain.

Authors:  Niels W L Schep; Robert Haverlag; Arie B van Vugt
Journal:  J Trauma       Date:  2004-12

10.  The lumbosacral nerves in relation to dorsal S1 screw placement and their locations on plain radiographs.

Authors:  N A Ebraheim; S P Haman; R Xu; S Stanescu; R A Yeasting
Journal:  Orthopedics       Date:  2000-03       Impact factor: 1.390

View more
  45 in total

1.  [Image-based guidance in shoulder traumatology. Initial clinical experience].

Authors:  M Kraus; C Dehner; C Riepl; M Bischoff; F Gebhard; H Schöll
Journal:  Unfallchirurg       Date:  2012-03       Impact factor: 1.000

2.  Precision insertion of percutaneous sacroiliac screws using a novel augmented reality-based navigation system: a pilot study.

Authors:  Huixiang Wang; Fang Wang; Anthony Peng Yew Leong; Lu Xu; Xiaojun Chen; Qiugen Wang
Journal:  Int Orthop       Date:  2015-11-16       Impact factor: 3.075

3.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

4.  Evaluation of 2D and 3D navigation for iliosacral screw fixation.

Authors:  Daniel Behrendt; Maria Mütze; Hanno Steinke; Martin Koestler; Christoph Josten; Jörg Böhme
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-18       Impact factor: 2.924

5.  O-arm navigation for sacroiliac screw placement in the treatment for posterior pelvic ring injury.

Authors:  Shengyu Lu; Keqin Yang; Cailing Lu; Ping'ou Wei; Zhi Gan; Zhipeng Zhu; Haitao Tan
Journal:  Int Orthop       Date:  2021-02-17       Impact factor: 3.075

Review 6.  [The new treatment procedures of the DGUV from the perspective of an injury type procedure (VAV) clinic].

Authors:  M Oberst
Journal:  Unfallchirurg       Date:  2017-09       Impact factor: 1.000

7.  Current state of computer-assisted trauma surgery.

Authors:  Barbara M Dirhold; Mustafa Citak; Hesham Al-Khateeb; Carl Haasper; Daniel Kendoff; Christian Krettek; Musa Citak
Journal:  Curr Rev Musculoskelet Med       Date:  2012-09

Review 8.  [The hybrid operating room. Home of high-end intraoperative imaging].

Authors:  F Gebhard; C Riepl; P Richter; A Liebold; H Gorki; R Wirtz; R König; F Wilde; A Schramm; M Kraus
Journal:  Unfallchirurg       Date:  2012-02       Impact factor: 1.000

9.  Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?

Authors:  Michael David Kraus; Gert Krischak; Peter Keppler; Florian T Gebhard; Uwe H W Schuetz
Journal:  Clin Orthop Relat Res       Date:  2010-06-03       Impact factor: 4.176

10.  MRI-guided navigation surgery with temporary implantable bone markers in limb salvage for sarcoma.

Authors:  June Hyuk Kim; Hyun Guy Kang; Han-Soo Kim
Journal:  Clin Orthop Relat Res       Date:  2010-01-07       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.