Literature DB >> 17242941

[Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

D Briem1, J Windolf, J M Rueger.   

Abstract

OBJECTIVE: In pelvic surgery, computer-assisted procedures are currently used predominantly for percutaneous iliosacral screw placement. The aim of this study was to evaluate the possibilities and limits of a 2D-fluoroscopic navigated procedure used for this indication.
METHODS: A consecutive series of patients with non or slightly displaced injuries of the posterior pelvic ring were prospectively investigated. Cannulated cancellous screws of 7.3 mm were percutaneously implanted in the supine position. The navigated procedure was performed using an active optoelectronical system and a 2D C-arm. Target parameters were practicability, precision and intraoperative radiation exposure time compared to patients treated using a non-navigated technique.
RESULTS: In a 15 month period, 35 screws were implanted in 20 patients. The average procedure took 36.2+/-12.5 min (range 18-62 min), with a fluoroscopic time of 0.9+/-0.3 min (range 0.6-1.8 min) per screw. The displacement rate was 8% (n=3/35, CI 1.8-23.0). Compared to retrospectively selected patients treated using a non-navigated technique (n=13), a significant increase in procedure time (P=0.01), a significant decrease of radiation exposure time (P<0.001) and a decreased displacement rate (P>0.05) were observed in the navigated group.
CONCLUSION: The 2D-fluoroscopic navigated procedure used in this study can be recommended for percutaneous stabilisation of non or minor displaced injuries of the posterior pelvis. This procedure reduces intraoperative radiation exposure and improves intraoperative orientation but does not crucially enhance the precision of screw placement compared to the non-navigated technique. Finally, it is limited by its poor image resolution and lack of three-dimensionality.

Entities:  

Mesh:

Year:  2007        PMID: 17242941     DOI: 10.1007/s00113-006-1226-y

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  25 in total

1.  [Navigation assisted by image conversion. An experimental study on pelvic screw fixation].

Authors:  U Stöckle; B König; R Hofstetter; L P Nolte; N P Haas
Journal:  Unfallchirurg       Date:  2001-03       Impact factor: 1.000

2.  [Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study].

Authors:  M Arand; E Hartwig; D Hebold; L Kinzl; F Gebhard
Journal:  Unfallchirurg       Date:  2001-11       Impact factor: 1.000

3.  [Computer-assisted surgery: developments and prospects in 2001. Results of a workshop at Schloss Reisenburg, 23-24 November 2000].

Authors:  F Gebhard; M Arand; T Fleiter; A Hebecker; P Heeckt; J Hesser; P Messmer; T Hüfner; H Visarius; P Regazzoni; L Kinzl
Journal:  Unfallchirurg       Date:  2001-08       Impact factor: 1.000

4.  [Accuracy of fluoroscopic navigation of pedicle screws. CT-based evaluation of bone screw placement].

Authors:  E Fritsch; J Duchow; R Seil; I Grunwald; W Reith
Journal:  Orthopade       Date:  2002-04       Impact factor: 1.087

5.  [Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique].

Authors:  K J Schnake; B König; U Berth; R J Schroeder; F Kandziora; U Stöckle; M Raschke; N P Haas
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

6.  [Computer-assisted surgery for pelvic injuries].

Authors:  T Hüfner; J Geerling; A Gänsslen; D Kendoff; C Citak; P Grützner; C Krettek
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

7.  [Evaluation of image quality of the Iso C3D image processor in comparison to computer tomography. Use in the pelvic area].

Authors:  B König; U Erdmenger; R J Schröder; G Wienas; J Schaefer; M Pech; U Stöckle
Journal:  Unfallchirurg       Date:  2005-05       Impact factor: 1.000

8.  Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model.

Authors:  Cory Collinge; David Coons; Paul Tornetta; John Aschenbrenner
Journal:  J Orthop Trauma       Date:  2005-04       Impact factor: 2.512

9.  [Computer-assisted screw osteosynthesis of the posterior pelvic ring. Initial experiences with an image reconstruction based optoelectronic navigation system].

Authors:  P A Grützner; E Rose; B Vock; F Holz; L P Nolte; A Wentzensen
Journal:  Unfallchirurg       Date:  2002-03       Impact factor: 1.000

10.  Computer-assisted versus conventional surgery for insertion of 96 cannulated iliosacral screws in patients with postpartum pelvic pain.

Authors:  Niels W L Schep; Robert Haverlag; Arie B van Vugt
Journal:  J Trauma       Date:  2004-12
View more
  12 in total

1.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

2.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

3.  In-screw cement augmentation for iliosacral screw fixation in posterior ring pathologies with insufficient bone stock.

Authors:  M A König; S Hediger; J W Schmitt; T Jentzsch; K Sprengel; C M L Werner
Journal:  Eur J Trauma Emerg Surg       Date:  2016-05-11       Impact factor: 3.693

4.  Evaluation of 2D and 3D navigation for iliosacral screw fixation.

Authors:  Daniel Behrendt; Maria Mütze; Hanno Steinke; Martin Koestler; Christoph Josten; Jörg Böhme
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-18       Impact factor: 2.924

5.  [Posterior approaches to the pelvic ring].

Authors:  W Lehmann; L Großterlinden; J M Rueger
Journal:  Unfallchirurg       Date:  2013-03       Impact factor: 1.000

6.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

Review 7.  2D versus 3D fluoroscopy-based navigation in posterior pelvic fixation: review of the literature on current technology.

Authors:  Savyasachi C Thakkar; Rashmi S Thakkar; Norachart Sirisreetreerux; John A Carrino; Babar Shafiq; Erik A Hasenboehler
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-08       Impact factor: 2.924

8.  [Variability of the screw position after 3D-navigated sacroiliac screw fixation. Influence of the surgeon's experience with the navigation technique].

Authors:  G Konrad; J Zwingmann; E Kotter; N Südkamp; M Oberst
Journal:  Unfallchirurg       Date:  2010-01       Impact factor: 1.000

9.  [Consequences of occult insufficiency fractures of the sacrum].

Authors:  D Briem; W Lehmann; L Grossterlinden; P G Begemann; M Amling; J M Rueger
Journal:  Unfallchirurg       Date:  2007-12       Impact factor: 1.000

10.  Percutaneous iliosacral screw fixation in unstable pelvic fractures.

Authors:  Hicham Bousbaa; Mohammed Ouahidi; Jamal Louaste; Mourad Bennani; Tawfiq Cherrad; Hassan Jezzari; El Houssine Kasmaoui; Khalid Rachid; Laarbi Amhajji
Journal:  Pan Afr Med J       Date:  2017-08-03
View more