Literature DB >> 9755769

Percutaneous iliosacral screw placement using image guided techniques.

J Tonetti1, L Carrat, S Lavalleé, L Pittet, P Merloz, J P Chirossel.   

Abstract

A computer assisted technique of iliosacral screw placement that is applicable to unstable pelvic ring fractures is proposed. The goals are to operate noninvasively with a percutaneous procedure to decrease the complications of surgical exposure and to provide greater accuracy in locating the close neurovascular structures. Preoperative computed tomographic images of the pelvis are provided and a computed tomography three-dimensional model is built. In this model, the optimal trajectories for the drilling are planned. An ultrasound based registration is performed intraoperatively. This registration is the most original part of this work. After performing the passive drilling guidance step, the surgeon places the screws. The accuracy of the ultrasound based registration is checked by comparison with a standard surface based registration at the end of the test experiment. Each screw position is verified by a computed tomographic examination. Four human anatomic specimen pelves were tested with three screw insertions for each pelvis (12 screws). All of the screws were considered to be placed correctly. The method is safe and encourages the start of clinical application.

Entities:  

Mesh:

Year:  1998        PMID: 9755769     DOI: 10.1097/00003086-199809000-00013

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  15 in total

1.  [The minimally invasive stabilization of the dorsal pelvic ring with the transiliacal internal fixator (TIFI)--surgical technique and first clinical findings].

Authors:  B Füchtmeier; M Maghsudi; C Neumann; R Hente; C Roll; M Nerlich
Journal:  Unfallchirurg       Date:  2004-12       Impact factor: 1.000

2.  Validation of automated ultrasound-CT registration of vertebrae.

Authors:  Charles X B Yan; Benoît Goulet; Sean Jy-Shyang Chen; Donatella Tampieri; D Louis Collins
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-11-24       Impact factor: 2.924

3.  Ultrasound-CT registration of vertebrae without reconstruction.

Authors:  Charles X B Yan; Benoît Goulet; Donatella Tampieri; D Louis Collins
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-06-15       Impact factor: 2.924

4.  Towards accurate, robust and practical ultrasound-CT registration of vertebrae for image-guided spine surgery.

Authors:  Charles X B Yan; Benoît Goulet; Julie Pelletier; Sean Jy-Shyang Chen; Donatella Tampieri; D Louis Collins
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-10-26       Impact factor: 2.924

5.  [Computer-assisted arthrodesis of the sacroiliac joint].

Authors:  F Gebhard; M Sarkar; G Maier; L Kinzl; M Arand
Journal:  Unfallchirurg       Date:  2005-09       Impact factor: 1.000

6.  Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.

Authors:  D Briem; W Linhart; W Lehmann; P G Begemann; G Adam; U Schumacher; D M Cullinane; J M Rueger; J Windolf
Journal:  Eur Spine J       Date:  2005-07-12       Impact factor: 3.134

7.  [A-mode ultrasonic pointer for navigated pelvic surgery].

Authors:  M Oszwald; M Citak; J Kowal; C Amstutz; D Kendoff; T Kirchhoff; L P Nolte; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-03       Impact factor: 1.000

8.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

9.  Transcondylar traction as a closed reduction technique in vertically unstable pelvic ring disruption.

Authors:  M Thaunat; F Laude; P Paillard; G Saillant; Y Catonné
Journal:  Int Orthop       Date:  2007-01-24       Impact factor: 3.075

10.  Immediate percutaneous sacroiliac screw insertion for unstable pelvic fractures: is it safe enough?

Authors:  A Acker; Z H Perry; S Blum; G Shaked; A Korngreen
Journal:  Eur J Trauma Emerg Surg       Date:  2016-03-14       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.