Literature DB >> 11284352

[Navigation assisted by image conversion. An experimental study on pelvic screw fixation].

U Stöckle1, B König, R Hofstetter, L P Nolte, N P Haas.   

Abstract

Within an experimental trial the new method of fluoroscopy based navigation was tested for percutaneous pelvic screw fixations. A regular C-arm was used and the navigation system developed by Medivision. In a first step appropriate C-arm projections were defined for five standardized screw positions. Then precision and fluoroscopy time of 60 screws in 6 artificial pelves were evaluated. For the sacroliacal screw in S1, S1 screw in S2, anterior column screw, posterior column screw and the supraacetabular ilium screw three to four appropriate projections were defined. These were all combinations of the known special pelvic views inlet/outlet and iliac/obturator. Using these standardized views the average fluoroscopy time was 6 seconds per screw. 51 screws (85%) were inserted correctly. In five cases there was a slight deviation without perforating the cortex, four times the cortex was perforated.

Mesh:

Year:  2001        PMID: 11284352     DOI: 10.1007/s001130050717

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  15 in total

1.  [CT and fluoroscopy based navigation in pelvic surgery].

Authors:  U Stöckle; B König; K Schaser; I Melcher; N P Haas
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

2.  Factors influencing the accuracy of iliosacral screw placement in trauma patients.

Authors:  Lars Grossterlinden; Johannes Rueger; Philip Catala-Lehnen; Martin Rupprecht; Wolfgang Lehmann; Andreas Rücker; Daniel Briem
Journal:  Int Orthop       Date:  2010-07-20       Impact factor: 3.075

3.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

4.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

5.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

Authors:  D Briem; J Windolf; J M Rueger
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

6.  [Integrated navigation. Preclinical evaluation and initial clinical experience].

Authors:  U Stöckle; A Schäffler; B König; N P Haas
Journal:  Unfallchirurg       Date:  2006-11       Impact factor: 1.000

7.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

8.  [Best matching. Experimental comparison of different matching procedures for use in computer navigation].

Authors:  A Schäffler; B König; N P Haas; U Stöckle
Journal:  Unfallchirurg       Date:  2009-09       Impact factor: 1.000

9.  Current state of computer-assisted trauma surgery.

Authors:  Barbara M Dirhold; Mustafa Citak; Hesham Al-Khateeb; Carl Haasper; Daniel Kendoff; Christian Krettek; Musa Citak
Journal:  Curr Rev Musculoskelet Med       Date:  2012-09

10.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.