The accuracy of computer-assisted percutaneous iliosacral screw placement.

Adrian C Day1, Philip M Stott, Richard A Boden.   

Abstract

The benchmark fluoroscopic technique of iliosacral screw insertion is disadvantaged by its reliance on ionizing radiation and presentation of dynamic information in only one plane. Multiplane targeting requires interpolation, which may be associated with inherent errors. Computer-assisted surgery enables surgeons to monitor their screw trajectory in 3-D space. The clinical application of computer-assisted surgery requires validation of its accuracy when tested against a benchmark technique. We simulated surgical implantation of cannulated screws in 10 embalmed human cadavers. Two specimens had sacral dysplasia. We inserted 20 screws into the S1 body, the left side by the benchmark fluoroscopic technique and the right side by a fluoroscopically registered computer-assisted surgery technique. All specimens were intact with no simulated injuries. A postoperative high-definition computed tomography scan showed the screw track. The actual track was compared with the intended screw track by a graphical technique. There was no deviation from the intended screw path in any of the simulated screw paths. With both techniques, two of the 10 tracks penetrated the sacral cortex in dysplastic pelvices. A fluoroscopic computer-assisted surgery technique appears as accurate as the standard fluoroscopic technique but no more so. Caution is recommended in dysplastic pelvices. (C) 2007 Lippincott Williams & Wilkins, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17960680

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

2.  Entry zone of iliac screw fixation to maintain proper entry width and screw length.

Authors:  Soo-An Park; Dai-Soon Kwak; Sung-Lim You
Journal:  Eur Spine J       Date:  2015-05-23       Impact factor: 3.134

3.  Standardized posterior pelvic imaging: use of CT inlet and CT outlet for evaluation and management of pelvic ring injuries.

Authors:  Christopher M McAndrew; David J Merriman; Michael J Gardner; William M Ricci
Journal:  J Orthop Trauma       Date:  2014-12       Impact factor: 2.512

4.  Preoperative planning and safe intraoperative placement of iliosacral screws under fluoroscopic control.

Authors:  Dietmar Krappinger; Richard A Lindtner; Stefan Benedikt
Journal:  Oper Orthop Traumatol       Date:  2019-06-03       Impact factor: 1.154

5.  Differences in Accuracy and Radiation Dose in Placement of Iliosacral Screws: Comparison between 3D and 2D Fluoroscopy.

Authors:  Michał Kułakowski; Paweł Reichert; Karol Elster; Jarosław Witkowski; Paweł Ślęczka; Piotr Morasiewicz; Łukasz Oleksy; Aleksandra Królikowska
Journal:  J Clin Med       Date:  2022-03-08       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.